9065-8T2GS-MR - VOLKTEK managed marine switch, 8× RJ45, 2× SFP

9065-8T2GS-MR - VOLKTEK managed marine switch, 8× RJ45, 2× SFP


VOLKTEK 9065-8T2GS-MR: managed marine switch, 8× RJ45 / 10/100 Mbit/s; 2× SFP / 100/1000 Mbit/s. 2× 12-48 V DC, IP40, DNV / LR. DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval. More

Manufacturer: VOLKTEK Code: 9065-8T2GS-MR

Rezervace termínu

Get a quote

VOLKTEK 9065-8T2GS-MR: managed marine switch, 8× RJ45 / 10/100 Mbit/s; 2× SFP / 100/1000 Mbit/s. 2× 12-48 V DC, IP40, DNV / LR. DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval. More

Manufacturer: VOLKTEK Code: 9065-8T2GS-MR

VOLKTEK 9065-8T2GS-MR

Ethernet for marine and offshore networks

Managed marine switch. 8× RJ45 / 10/100 Mbit/s; 2× SFP / 100/1000 Mbit/s. Connects PLCs, HMIs and other Ethernet devices in marine automation. Metal DIN-rail design with documented marine approval and separate conditions for installation under DNV.

8× RJ45 / 10/100 Mbit/sManaged marine switch2× 12-48 V DCIP40 / DIN rail

DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval.
The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions.
2 DIP switches enable or disable alarms for the primary PWR and redundant RPS inputs. They do not configure VLANs or port speed.

VOLKTEK 9065-8T2GS-MR - Front view
Front view. Click to enlarge the image.

We’ll select a switch for your industrial network
We can help you choose the right model and power supply. We will confirm the price, current stock availability and delivery date.

Request a VOLKTEK solution
8× Fast EthernetAutomatic port speed negotiation
DNV / LRMarine approval for the exact model
-25…+70 °CDNV Class D / 24 V DC

Marine approval and operating conditions

DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval.

LR: environmental categories ENV1, ENV2 and ENV3.

The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions.

Assess the approval scope for the exact order code and installation. We will check the required documentation and requirements for environment, power and cabinet placement.

Technical specifications

Order codeVOLKTEK 9065-8T2GS-MR
DesignManaged marine switch
Copper ports8× RJ45 / 10/100 Mbit/s
SFP slots2× SFP / 100/1000 Mbit/s
Switching capacity5,6 Gbit/s
MAC address table16K
Maximum frame length10 Kbytes
Power inputs2 inputs / 12-48 V DC
Power consumption14 W
HousingIP40
Marine approvalDNV; LR ENV1 / ENV2 / ENV3
DNV Class D conditions-25…+70 °C / 24 V DC
Protection under DNV Type ApprovalIP20
General device operating temperature-40…+75 °C
Dimensions (W × H × D)50 × 161.5 × 119.9 mm
Weight970 g
MountingDIN rail
Console and USBRS-232 (RJ45), USB
Management and monitoringWeb, CLI, HTTPS, SSH, SNMP v1/v2c/v3
VLANIEEE 802.1Q / 4K
Network redundancySTP/RSTP/MSTP, Xpress Ring, ERPS
Link aggregationLACP
Relay alarm1 A / 24 V DC
DIP switches2 DIP switches enable or disable alarms for the primary PWR and redundant RPS inputs. They do not configure VLANs or port speed.

Communication and network functions

Management and Monitoring

The web interface, CLI and SNMP v1/v2c/v3 provide network configuration and monitoring. SSH, HTTPS, 802.1X, ACL and TACACS+ support access control. An RS-232 console via RJ45 and USB provide additional local access options.

VLANs and network redundancy

IEEE 802.1Q VLAN, up to 4K active VLANs, STP/RSTP/MSTP, Xpress Ring, ERPS and LACP support network segmentation and redundant paths. Static routing and Inter-VLAN routing are supported. Configure these functions for your topology.

Power supply and alarm

2× 12-48 V DC. Two PWR and RPS inputs allow connection to two power sources. If one fails, the other can continue supplying the device. The relay alarm is rated 1 A / 24 V DC. A separate backed-up supply is required to bridge failure of both sources.

2 DIP switches enable or disable alarms for the primary PWR and redundant RPS inputs. They do not configure VLANs or port speed.

Interfaces and mounting

VOLKTEK 9065-8T2GS-MR - Interface diagram
Interface diagram. Original manufacturer diagram with English labels. Click to enlarge the image.
VOLKTEK 9065-8T2GS-MR - Dimensional drawing
Dimensional drawing 50 × 161.5 × 119.9 mm. Click to enlarge the image.

Install in a suitable cabinet or protective enclosure. Provide grounding, free airflow and access to connectors. Neither IP30 nor IP40 provides protection against water. Wire with power disconnected and follow the installation guide.

Package contents

  • 1× VOLKTEK 9065-8T2GS-MR
  • 1× DIN-rail mounting kit

Select the power supply separately. For SFP versions, select optical modules according to fibre, speed, distance and temperature conditions.

Downloads

Original VOLKTEK documentation in English. Files are also available in the Downloads tab.

Datasheet 9065-8T2GS-MRVOLKTEK / ENOpen PDF
Quick installation guide 9065-8T2GS-MRVOLKTEK / ENOpen PDF

VOLKTEK videos

Official introduction to marine switches and their applications. Videos are in English.

Marine networks: DNV and LR (EN)

Industrial switch portfolio (EN)

Frequently asked questions

Which conditions apply to marine approval?

DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval. The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions. LR: environmental categories ENV1, ENV2 and ENV3.

Does the switch require configuration?

The web interface, CLI and SNMP v1/v2c/v3 provide network configuration and monitoring. SSH, HTTPS, 802.1X, ACL and TACACS+ support access control. An RS-232 console via RJ45 and USB provide additional local access options.

Which power supply should I use?

2× 12-48 V DC. Two PWR and RPS inputs allow connection to two power sources. If one fails, the other can continue supplying the device. The relay alarm is rated 1 A / 24 V DC. A separate backed-up supply is required to bridge failure of both sources.

What do the DIP switches control?

2 DIP switches enable or disable alarms for the primary PWR and redundant RPS inputs. They do not configure VLANs or port speed.

How do I select an optical connection?

Select SFP modules according to the slot speed, fibre type, connector and required distance. For marine operation, also check their temperature range and installation requirements.

Can you help with selection and availability?

We supply new original VOLKTEK products with warranty. We will discuss port count and speed, power supply and marine requirements, then confirm the price, current availability and delivery time before ordering.

Why buy from FOXON?

We are a VOLKTEK distributor. We supply new, genuine products and assist with their selection and use in industrial networks.

New products with a warranty

We supply the 9065-8T2GS-MR as a new, genuine VOLKTEK switch with a warranty and manufacturer documentation.

Technical support

We can advise you on selecting a switch, power supply and accessories. We will discuss the wiring and requirements of your application.

Stock availability and delivery

We will check current stock availability and confirm the price and estimated delivery date before you place your order.

Pre-purchase consultation

We help select a model based on device count, transfer speed, power supply and operating conditions. We will discuss network management, VLAN and traffic monitoring requirements.

More than 3,500customers
We supply tomore than 100 countries worldwide
Express delivery?We’ll look into it; please contact us immediately.

Enquiry and technical consultation

New original product with warranty. Availability and delivery time confirmed on enquiry.

Assess the approval scope for the exact order code and installation. We will check the required documentation and requirements for environment, power and cabinet placement.

We’ll select a switch for your industrial network
We can help you choose the right model and power supply. We will confirm the price, current stock availability and delivery date.

Request a VOLKTEK solution
Parameters
Switch management Managed
Number of copper ports 8
Number of fixed fiber ports 0
Number of SFP slots 2
Number of SFP+ slots 0
Copper port speed 100 Mbit/s

Technical specifications

Order codeVOLKTEK 9065-8T2GS-MR
DesignManaged marine switch
Copper ports8× RJ45 / 10/100 Mbit/s
SFP slots2× SFP / 100/1000 Mbit/s
Switching capacity5,6 Gbit/s
MAC address table16K
Maximum frame length10 Kbytes
Power inputs2 inputs / 12-48 V DC
Power consumption14 W
HousingIP40
Marine approvalDNV; LR ENV1 / ENV2 / ENV3
DNV Class D conditions-25…+70 °C / 24 V DC
Protection under DNV Type ApprovalIP20
General device operating temperature-40…+75 °C
Dimensions (W × H × D)50 × 161.5 × 119.9 mm
Weight970 g
MountingDIN rail
Console and USBRS-232 (RJ45), USB
Management and monitoringWeb, CLI, HTTPS, SSH, SNMP v1/v2c/v3
VLANIEEE 802.1Q / 4K
Network redundancySTP/RSTP/MSTP, Xpress Ring, ERPS
Link aggregationLACP
Relay alarm1 A / 24 V DC
DIP switches2 DIP switches enable or disable alarms for the primary PWR and redundant RPS inputs. They do not configure VLANs or port speed.

Marine approval and operating conditions

DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval.

The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions.

Frequently asked questions

Which conditions apply to marine approval?

DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval. The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions. LR: environmental categories ENV1, ENV2 and ENV3.

Does the switch require configuration?

The web interface, CLI and SNMP v1/v2c/v3 provide network configuration and monitoring. SSH, HTTPS, 802.1X, ACL and TACACS+ support access control. An RS-232 console via RJ45 and USB provide additional local access options.

Which power supply should I use?

2× 12-48 V DC. Two PWR and RPS inputs allow connection to two power sources. If one fails, the other can continue supplying the device. The relay alarm is rated 1 A / 24 V DC. A separate backed-up supply is required to bridge failure of both sources.

What do the DIP switches control?

2 DIP switches enable or disable alarms for the primary PWR and redundant RPS inputs. They do not configure VLANs or port speed.

How do I select an optical connection?

Select SFP modules according to the slot speed, fibre type, connector and required distance. For marine operation, also check their temperature range and installation requirements.

Can you help with selection and availability?

We supply new original VOLKTEK products with warranty. We will discuss port count and speed, power supply and marine requirements, then confirm the price, current availability and delivery time before ordering.