MEAN WELL XDR-240E-24 - DIN rail power supply, 24 V DC, 10 A, 240 W
- UPS and power supplies
- Power supplies
- MEAN WELL XDR-240E-24 - DIN rail power supply, 24 V DC, 10 A, 240 W
MEAN WELL XDR-240E-24 - DIN rail power supply, 24 V DC, 10 A, 240 W
Industrial switching power supply for DIN rail mounting. Output 24 V DC, 10 A, 240 W, adjustable from 24 to 29 V DC. Input 85 to 264 V AC / 120 to 370 V DC, 40 mm wide, active PFC and DC OK contact. More
Code: XDR-240E-24
Industrial switching power supply for DIN rail mounting. Output 24 V DC, 10 A, 240 W, adjustable from 24 to 29 V DC. Input 85 to 264 V AC / 120 to 370 V DC, 40 mm wide, active PFC and DC OK contact. More
Code: XDR-240E-24
XDR-240E-24 - 240 W for industrial automation
MEAN WELL XDR-240E-24 converts mains voltage to a regulated 24 V DC output with a current of up to 10 A. Its slim 40 mm design saves space in the control cabinet. The power supply features active PFC, fanless cooling and a DC OK relay contact for monitoring the output voltage.
Looking to buy or repair this power supply?
We will check the availability of a new power supply and the options for diagnosing and professionally repairing a faulty unit. Price on request.
XDR-240E-24 applications
The power supply is designed for industrial control systems, factory automation and electromechanical equipment. In a control cabinet, it provides a 24 V DC supply rail for devices with the appropriate voltage rating and a combined demand within its power limits.
When selecting a power supply, consider the continuous load, the starting currents of connected devices and the temperature inside the cabinet. The adjustable 24 to 29 V DC output helps match the voltage to the application; the 240 W power limit still applies when the voltage is increased.
MEAN WELL XDR-240E-24 technical specifications
| Manufacturer / part number | MEAN WELL / XDR-240E-24 |
|---|---|
| Design | AC/DC switching power supply for DIN rail mounting |
| Rated output voltage | 24 V DC |
| Rated output current | 10 A; operating range 0 to 10 A |
| Rated output power | 240 W |
| Output voltage adjustment | 24 to 29 V DC; total power must not exceed 240 W |
| AC input voltage | 85 to 264 V AC, 47 to 63 Hz; load derating is required below 100 V AC |
| DC input voltage | 120 to 370 V DC |
| Typical efficiency | 95.2 % at 230 V AC, rated load and an ambient temperature of 25 °C |
| No-load power consumption | Typically 1 W at 115 / 230 V AC |
| Active PFC | Typical power factor >0.95 at 230 V AC and >0.98 at 115 V AC, at full load |
| Ripple and noise | Max. 100 mV peak-to-peak; measured with a 20 MHz bandwidth and the specified measurement setup |
| Output voltage tolerance | ±1.0 %, including setting tolerance, line regulation and load regulation |
| Hold-up time | Typically 20 ms at 115 / 230 V AC and full load |
| Protection | Short circuit, overload, output overvoltage and overheating |
| DC OK contact | Closed when the output voltage is correct; max. 30 V DC / 1 A or 30 V AC / 0.5 A, resistive load |
| Operating temperature | -40 to +70 °C; gradual load derating above +50 °C, at +70 °C a maximum of 75 % |
| Operating humidity | 20 to 95 % relative humidity, non-condensing |
| Cooling | Natural air convection, without a fan |
| Mounting | TS-35/7.5 or TS-35/15 DIN rail, vertical orientation |
| Dimensions (W × H × D) | 40 × 125.2 × 116 mm |
| Catalogue weight | 610 g |
Power and operating conditions: Load derating is required at input voltages below 100 V AC and ambient temperatures above +50 °C. Above an altitude of 2,000 m, the permissible ambient temperature is reduced by 3.5 °C for every additional 1,000 m.
DC OK monitoring, protection and installation
The potential-free DC OK contact is closed when the output voltage is correct and opens when the power supply is switched off or the output fails. Use an external circuit for signalling and observe the contact ratings.
Overload protection operates at 105 to 130 % of rated power. The power supply limits the current; if the output drops below 30 % of rated voltage, it switches to repeated restart attempts. Normal operation resumes automatically once the fault is removed. Overtemperature protection shuts down the output and restores it after cooling.
For vertical mounting and continuous full-load operation, leave the recommended clearances of 40 mm above the power supply, 20 mm below it and 5 mm on each side. Next to equipment that generates heat, leave the recommended side clearance of 15 mm. Keep the ventilation openings unobstructed.
Scope of delivery
MEAN WELL XDR-240E-24 power supply. We will confirm the exact scope of delivery in the quotation. Select the DIN rail, supply wiring and other cabinet equipment separately to suit the installation.
Frequently asked questions
Can it replace another 24 V / 10 A power supply?
Matching voltage and current ratings are the starting point. Before replacement, also check the input supply, dimensions, terminals, required signalling and starting current of the connected equipment. Send us the original power supply designation and load details.
Can the power supply operate at 29 V and deliver 10 A?
When the output voltage is increased, the current must be reduced so that output power does not exceed 240 W. The rated 10 A applies to a 24 V DC output.
Does the power supply deliver full power at +70 °C?
No. With vertical mounting, full power is available up to +50 °C. Reduce the load above this temperature; at +70 °C, the maximum permissible load is 75 %, or 180 W.
Does the power supply provide backup during a mains failure?
Battery backup requires a separate backup system. The typical 20 ms hold-up time at full load only bridges a very brief dip or loss of the input supply.
Can I request diagnosis and repair of a faulty power supply?
Yes. Send us a photograph of the nameplate and a description of the fault. We will check diagnosis and repair options and compare them with supplying a new power supply.
Available product conditions
You can request a new original XDR-240E-24 power supply. If you require a different product condition or a replacement for an existing power supply, include this in your enquiry. We will confirm availability, condition, price and delivery time in a specific quotation.
Sales, repairs and purchase of surplus automation parts
FOXON supplies industrial automation parts in Czechia and internationally and provides diagnosis and repair of faulty parts. For each specific power supply, we first assess the appropriate approach.
Request a quote for the XDR-240E-24
Send us the quantity, required delivery date and parameters of the load to be powered. For diagnosis or repair enquiries, include a photograph of the nameplate and a description of the fault.
Request a purchase or repair quote| Manufacturer / part number | MEAN WELL / XDR-240E-24 |
|---|---|
| Design | AC/DC switching power supply for DIN rail mounting |
| Rated output voltage | 24 V DC |
| Rated output current | 10 A; operating range 0 to 10 A |
| Rated output power | 240 W |
| Output voltage adjustment | 24 to 29 V DC; total power must not exceed 240 W |
| AC input voltage | 85 to 264 V AC, 47 to 63 Hz; load derating is required below 100 V AC |
| DC input voltage | 120 to 370 V DC |
| Typical efficiency | 95.2 % at 230 V AC, rated load and an ambient temperature of 25 °C |
| No-load power consumption | Typically 1 W at 115 / 230 V AC |
| Active PFC | Typical power factor >0.95 at 230 V AC and >0.98 at 115 V AC, at full load |
| Ripple and noise | Max. 100 mV peak-to-peak; measured with a 20 MHz bandwidth and the specified measurement setup |
| Output voltage tolerance | ±1.0 %, including setting tolerance, line regulation and load regulation |
| Hold-up time | Typically 20 ms at 115 / 230 V AC and full load |
| Protection | Short circuit, overload, output overvoltage and overheating |
| DC OK contact | Closed when the output voltage is correct; max. 30 V DC / 1 A or 30 V AC / 0.5 A, resistive load |
| Operating temperature | -40 to +70 °C; gradual load derating above +50 °C, at +70 °C a maximum of 75 % |
| Operating humidity | 20 to 95 % relative humidity, non-condensing |
| Cooling | Natural air convection, without a fan |
| Mounting | TS-35/7.5 or TS-35/15 DIN rail, vertical orientation |
| Dimensions (W × H × D) | 40 × 125.2 × 116 mm |
| Catalogue weight | 610 g |