Converter Modbus TCP Slave / SNMP Manager - HD67176-A1

Converter Modbus TCP Slave / SNMP Manager - HD67176-A1

New

ADFweb

The ADFweb HD67176-A1 connects Modbus TCP Slave and SNMP Manager communication. It transfers configured values between an industrial system and network supervision according to a prepared data map. More

Code: HD67176-A1

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67176-A1 connects Modbus TCP Slave and SNMP Manager communication. It transfers configured values between an industrial system and network supervision according to a prepared data map. More

Code: HD67176-A1

ADFweb HD67176-A1

Modbus TCP Slave / SNMP Manager

The ADFweb HD67176-A1 connects Modbus TCP Slave and SNMP Manager communication. It transfers configured values between an industrial system and network supervision according to a prepared data map.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
Modbus TCP Slave / SNMP ManagerProtocol connection
SNMP ManagerSNMP role
SW67176Configuration tool

Converter applications

Poll configured SNMP agents and expose their data to a Modbus TCP Master system. It acts as a Modbus TCP Slave for a PLC or SCADA and as an SNMP Manager for connected network devices.

Technical specifications HD67176-A1

Order codeHD67176-A1
Protocol connectionModbus TCP Slave / SNMP Manager
SNMP roleSNMP Manager
InterfacesEthernet RJ45 for both protocols
SNMP versionsSNMPv1, SNMPv2, SNMPv3
Data map rangeTo be confirmed for the required registers before ordering
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the supplied versionTo be confirmed for the hardware version before ordering
Device weightapproximately 200 g
Configuration softwareSW67176

For an older device, check the hardware version and connections against its label.

Communication and configuration

Use SW67176 to prepare the converter configuration. Configure the Modbus TCP Slave and SNMP request list with agent IP addresses, OIDs and data types. Select the SNMP version and corresponding credentials. PLC or SCADA registers must match the prepared mapping.

Prepare exact device types, required SNMP OIDs, data types and read/write permissions. Availability of specific values depends on the connected device MIB and access rights. SNMP support alone does not guarantee access to all device functions.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67176-A1
Dimensional drawing of the version shown - HD67176-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. Prepare exact device types, required SNMP OIDs, data types and read/write permissions. Availability of specific values depends on the connected device MIB and access rights. SNMP support alone does not guarantee access to all device functions.

How is this converter configured?

Use SW67176 to prepare the converter configuration. Configure the Modbus TCP Slave and SNMP request list with agent IP addresses, OIDs and data types. Select the SNMP version and corresponding credentials. PLC or SCADA registers must match the prepared mapping.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

Prepare exact device types, required SNMP OIDs, data types and read/write permissions. Availability of specific values depends on the connected device MIB and access rights. SNMP support alone does not guarantee access to all device functions.

Converter enquiry HD67176-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67176-A1

Order codeHD67176-A1
Protocol connectionModbus TCP Slave / SNMP Manager
SNMP roleSNMP Manager
InterfacesEthernet RJ45 for both protocols
SNMP versionsSNMPv1, SNMPv2, SNMPv3
Data map rangeTo be confirmed for the required registers before ordering
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the supplied versionTo be confirmed for the hardware version before ordering
Device weightapproximately 200 g
Configuration softwareSW67176

For an older device, check the hardware version and connections against its label.