Converter BACnet/IP Server / J1939 - HD67685-IP-A1

Converter BACnet/IP Server / J1939 - HD67685-IP-A1


ADFweb

The ADFweb HD67685-IP-A1 connects J1939 data to BACnet/IP as a Server. More

Code: HD67685-IP-A1

499 EUR excl. VAT (603,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67685-IP-A1 connects J1939 data to BACnet/IP as a Server. More

Code: HD67685-IP-A1

ADFweb HD67685-IP-A1

BACnet/IP Server / J1939

The ADFweb HD67685-IP-A1 connects J1939 data to BACnet/IP as a Server.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
BACnet/IP Server / J1939Protocol connection
35 mm DIN railHardware version
SW67685Configuration tool

Converter applications

As a BACnet Server, it exposes objects containing J1939 values to an external BACnet Client. It supports up to 2,048 BACnet objects in total for reading and writing.

Technical specifications HD67685-IP-A1

Order codeHD67685-IP-A1
Protocol connectionBACnet/IP Server / J1939
Interfaces and portsJ1939 (CAN); Ethernet RJ45
BACnet object capacityup to 2,048 in total
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67685

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67685, configure BACnet/IP, objects, J1939 messages and data mapping between both protocols.

The IP version uses BACnet/IP over Ethernet. The BACnet role must match the connected system; MS/TP requires a different order code. For configuration, prepare PGNs, device addresses, transfer direction and data positions in received and transmitted J1939 messages. Check value meanings, units and any scaling against the connected device documentation.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67685-IP-A1
Dimensional drawing of the version shown - HD67685-IP-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The IP version uses BACnet/IP over Ethernet. The BACnet role must match the connected system; MS/TP requires a different order code. For configuration, prepare PGNs, device addresses, transfer direction and data positions in received and transmitted J1939 messages. Check value meanings, units and any scaling against the connected device documentation.

How is this converter configured?

In SW67685, configure BACnet/IP, objects, J1939 messages and data mapping between both protocols.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The IP version uses BACnet/IP over Ethernet. The BACnet role must match the connected system; MS/TP requires a different order code. For configuration, prepare PGNs, device addresses, transfer direction and data positions in received and transmitted J1939 messages. Check value meanings, units and any scaling against the connected device documentation.

Converter enquiry HD67685-IP-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67685-IP-A1

Order codeHD67685-IP-A1
Protocol connectionBACnet/IP Server / J1939
Interfaces and portsJ1939 (CAN); Ethernet RJ45
BACnet object capacityup to 2,048 in total
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)123 × 22.5 × 90.7 mm
Device weightapproximately 200 g
Configuration softwareSW67685

For an older device, check the hardware version and connections against its label.