6SL3220-1YE56-1CB0
6SL3220-1YE56-1CB0
SINAMICS G120X Rated power: 315 kW at 135% 3 s or 110% 60 s, 100% 240 s; RFI suppression filter For category C3 3AC380-480V+10/-20% 47-63Hz Ambient temperature 0 to +45 °C Size: FSH Degree of protection IP20 / UL open type Without operator panel With IO expansion Fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS More
Code: 6SL3220-1YE56-1CB0
SINAMICS G120X Rated power: 315 kW at 135% 3 s or 110% 60 s, 100% 240 s; RFI suppression filter For category C3 3AC380-480V+10/-20% 47-63Hz Ambient temperature 0 to +45 °C Size: FSH Degree of protection IP20 / UL open type Without operator panel With IO expansion Fieldbus integrated: MODBUS RTU, BACnet MS/TP,USS More
Code: 6SL3220-1YE56-1CB0
6SL3220-1YE56-1CB0 – SINAMICS G120X
Siemens 6SL3220-1YE56-1CB0: SINAMICS G120X.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6SL3220-1YE56-1CB0 |
| Input / Line frequency | 47 ... 63 Hz |
| Input / Rated voltage | 400V IEC 480V NEC |
| Input / Rated current (LO) | 585.00 A / 486.00 A |
| Input / Rated current (HO) | 477.00 A / 397.00 A |
| Output / Number of phases | 3 AC |
| Output / Rated power (LO) | 315.00 kW / 400.00 hp |
| Output / Rated power (HO) | 250.00 kW / 300.00 hp |
| Output / Rated current (LO) | 570.00 A / 477.00 A |
| Output / Rated current (HO) | 468.00 A / 390.00 A |
| Output / Rated current (IN) | 585.00 A |
| Output / Max. output current | 770.00 A |
| Output / Pulse frequency | 4 kHz |
| Efficiency η | 0.98 |
| Inputs / outputs / Standard digital inputs / Number | 6 |
| Inputs / outputs / Fail-safe digital inputs / Number | 1 |
| Inputs / outputs / Digital outputs / Number as relay changeover contact | 2 |
| Inputs / outputs / Digital outputs / Number as transistor | 0 |
| Inputs / outputs / Analog / digital inputs / Number | 2 (Differential input) |
| Inputs / outputs / Analog outputs / Number | 1 (Non-isolated output) |
| Ambient conditions / Cooling | Air cooling using an integrated fan |
| Ambient conditions / Cooling air requirement | 0.362 m³/s |
| Ambient conditions / Installation altitude | 1,000 m |
| Ambient conditions / Ambient temperature / Operation | 0 ... 45 °C |
| Ambient conditions / Ambient temperature / Transport | -40 ... 70 °C |
| Ambient conditions / Ambient temperature / Storage | -25 ... 55 °C |
| Connections / Signal cable / Conductor cross-section | 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) |
| Connections / Line side / Version | M12 screw |
| Connections / Line side / Conductor cross-section | 4 x 240.00 mm² (MCM 2 x 500 ... MCM 4 x 500) |
| Connections / Motor end / Version | M12 screw |
| Connections / Motor end / Conductor cross-section | 4 x 240.00 mm² (MCM 2 x 500 ... MCM 4 x 500) |
| Connections / Max. motor cable length / Shielded | 150 m |
| Degree of protection | IP20 / UL open type |
| Frame size | FSH |
| Net weight | 151 kg |
| Inputs / outputs / Digital inputs / Conductor cross-section | 0.5 … 1.5 mm² (AWG 21 … AWG 16) Alternatively 2 x 0.5 mm² |
| Inputs / outputs / Digital inputs / Input voltage (0→1) | 11 V |
| Inputs / outputs / Digital inputs / Input voltage (1→0) | 5 V |
| Inputs / outputs / Digital inputs / Input voltage, max. | 30 V |
| Inputs / outputs / Digital outputs / Number of digital outputs | 4 |
| Inputs / outputs / Digital outputs / Conductor cross-section | 1.5 mm² (AWG 16) |
| Inputs / outputs / Analog inputs / Conductor cross-section | 0.5 … 1.5 mm² (AWG 21 … AWG 16) alternatively 2*0.5 mm² |
| Inputs / outputs / Analog outputs / Number of analog outputs | 2 |
| Inputs / outputs / Analog outputs / Conductor cross-section | 0.5 … 1.5 mm² (AWG 21 … AWG 16) Alternatively 2 x 0.5 mm² |
| Inputs / outputs / Analog outputs / Output voltage | 0 … 10 V |
| Input / Number of phases | 3 AC |
| Output / Rated current | 628.0 A |
| Dimensions / Degree of protection | IP00 |
| Dimensions / Net weight | 41.4 kg |
Calculated values may differ from nameplate ratings.
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.