6ES7453-3AH00-0AE0

6ES7453-3AH00-0AE0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-400, function module FM 453, (3-channel) for positioning with servo and stepper motors, incl. configuration package on CD More

Code: 6ES7453-3AH00-0AE0

Total in stock: 5 pcs External stock 5 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-400, function module FM 453, (3-channel) for positioning with servo and stepper motors, incl. configuration package on CD More

Code: 6ES7453-3AH00-0AE0

Part Sales 3

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7453-3AH00-0AE0 NC 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request
New without box (NW) 6ES7453-3AH00-0AE0 NW 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7453-3AH00-0AE0 R 12/24 months In external stock 3 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7453-3AH00-0AE0 O 3-6 weeks 24 months On request Enquire a repair

6ES7453-3AH00-0AE0 – FM 453

SIMATIC S7-400, function module FM 453, (3-channel) for positioning with servo and stepper motors, incl. configuration package on CD

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Auxiliary voltage 1L+, load voltage 2L+ / Rated value (DC)
20.4 V; Dynamic 18.5 VSupply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, lower limit (DC)
28.8 V; dynamic 30.2 VSupply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, upper limit (DC)

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7453-3AH00-0AE0
Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / Rated value (DC)24 V
Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, lower limit (DC)20.4 V; Dynamic 18.5 V
Supply voltage / Auxiliary voltage 1L+, load voltage 2L+ / permissible range, upper limit (DC)28.8 V; dynamic 30.2 V
Input current / from load voltage1L+, max.1 A; with 24 V position encoder; 1 A for 5 V position encoder
Input current / from load voltage 2L+ to 4L+, max.2 A; Per channel
Input current / from backplane bus 5 V DC, max.1.6 A; Rated current
Encoder supply / 5 V encoder supply / 5 VYes
Encoder supply / 5 V encoder supply / Output current, max.300 mA
Encoder supply / 5 V encoder supply / Cable length, max.35 m; at max. 210 mA; 25 m at max. 300 mA
Encoder supply / 24 V encoder supply / 24 VYes
Encoder supply / 24 V encoder supply / Cable length, max.100 m; at max. 300 mA
Power loss / Power loss, typ.8 W
Digital inputs / Number of digital inputs6; for each channel/axis
Digital inputs / Functionsconfigurable
Digital inputs / Input voltage / Rated value (DC)24 V
Digital inputs / Input voltage / for signal "0"-3 to +5 V (max. 3 mA)
Digital inputs / Input voltage / for signal "1"11 to 30 V (max. 7 mA)
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", max.15 µs; via input voltage range, 8 µs at 24 V DC
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at "1" to "0", max.45 µs; via input voltage range
Digital outputs / Number of digital outputs4; for each channel/axis
Digital outputs / Functionsconfigurable
Digital outputs / Short-circuit protectionYes
Digital outputs / Output voltage / Rated value (DC)24 V
Digital outputs / Output voltage / for signal "1", min.UP - 0,3 V
Digital outputs / Output current / for signal "1" rated value0.5 A; at 40 °C; 0.1 A at 60 °C
Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.0.6 A
Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.0.12 A
Digital outputs / Output current / for signal "0" residual current, max.2 mA
Digital outputs / Switching frequency / with resistive load, max.100 Hz
Digital outputs / Switching frequency / with inductive load, max.0.25 Hz
Encoder / Connectable encoders / Incremental encoder (symmetrical)Yes
Encoder / Connectable encoders / Absolute encoder (SSI)Yes
Encoder / Encoder signals, incremental encoder (symmetrical) / Input voltage5 V difference signal (phys. RS 422)
Encoder / Encoder signals, incremental encoder (symmetrical) / Input frequency, max.1 MHz; for 10 m cable length; 0.5 MHz for 35 m cable length
Encoder / Encoder signals, absolute encoder (SSI) / Input signal5 V difference signal (phys. RS 422)
Encoder / Encoder signals, absolute encoder (SSI) / Clock frequency, max.1.25 Mbit/s at 10 cable length (2.5 Mbit/s available soon)
Encoder / Encoder signals, absolute encoder (SSI) / Cable length, shielded, max.250 m; At max. 156 kbit/s
Drive interface / Signal Input / TypeDrive interface step, signal input "READY 1"
Drive interface / Signal Input / Function"Power section ready" where Ui < 1 V, Ii = 2 mA
Drive interface / Analog drive / Setpoint signal / Rated voltage range-10 to +10V
Drive interface / Analog drive / Setpoint signal / Output current-3 to +3 mA
Drive interface / Analog drive / Setpoint signal / Cable length, max.30 m
Drive interface / Analog drive / Output controller enable / Switching voltage, max.50 V
Drive interface / Analog drive / Output controller enable / Switching current, max.1 A
Drive interface / Analog drive / Output controller enable / Switching capacity, max.30 V·A
Drive interface / Stepper drive / Differential output voltage, min.2 V; RL = 100 Ohm
Drive interface / Stepper drive / Differential output voltage for signal "0", max.1.1 V; Io = 30 mA
Drive interface / Stepper drive / Differential output voltage for signal "1", min.3.7 V; Io = -30 mA
Drive interface / Stepper drive / Load resistance, min.55 Ω
Drive interface / Stepper drive / Output current, max.60 mA
Drive interface / Stepper drive / Pulse frequency200 kHz; 500 kHz available soon
Drive interface / Stepper drive / Cable length, shielded, max.35 m; 35 m with symm. transmission; 10 m with asymm. transmission
Potential separation / Potential separation digital inputs / Potential separation digital inputsYes; Optocoupler
Potential separation / Potential separation digital outputs / Potential separation digital outputsYes; Optocoupler
Ambient conditions / Ambient temperature during operation / min.0 °C
Ambient conditions / Ambient temperature during operation / max.55 °C
Ambient conditions / Ambient temperature during storage/transportation / min.-40 °C
Ambient conditions / Ambient temperature during storage/transportation / max.70 °C
Connection method / required front connector1x 48-pin
Dimensions / Width50 mm
Dimensions / Height290 mm
Dimensions / Depth210 mm
Weights / Weight, approx.1 620 g

Connections and conditions of use

  • Digital inputs / Input voltage / for signal "0": -3 to +5 V (max. 3 mA)
  • Digital inputs / Input voltage / for signal "1": 11 to 30 V (max. 7 mA)
  • Digital outputs / Output voltage / for signal "1", min.: UP - 0,3 V
  • Digital outputs / Output current / for signal "1" rated value: 0.5 A; at 40 °C; 0.1 A at 60 °C
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.: 5 mA
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.: 0.6 A
  • Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.: 5 mA
  • Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.: 0.12 A

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair