6ES7355-2SH00-0AE0

6ES7355-2SH00-0AE0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300, temperature Control Unit FM 355-2S, 4 channels, Step and pulse, 4 AI+8 DI+8 DO incl. multi-language configuration package, Manual and Getting Started (de, de, fr, en it) on CD-ROM More

Code: 6ES7355-2SH00-0AE0

from 667 EUR excl. VAT (807,07 EUR Incl. VAT)
Total in stock: 2 pcs External stock 2 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300, temperature Control Unit FM 355-2S, 4 channels, Step and pulse, 4 AI+8 DI+8 DO incl. multi-language configuration package, Manual and Getting Started (de, de, fr, en it) on CD-ROM More

Code: 6ES7355-2SH00-0AE0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7355-2SH00-0AE0 NC 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7355-2SH00-0AE0 R 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7355-2SH00-0AE0 O 3-6 weeks 24 months On request Enquire a repair

6ES7355-2SH00-0AE0 – FM 355-2S

SIMATIC S7-300, temperature Control Unit FM 355-2S, 4 channels, step and pulse, 4 AI+8 DI+8 DO incl. multi-language configuration package, manual and Getting Started (de, en, it) on CD-ROM

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Load voltage L+ / Rated value (DC)
20.4 VSupply voltage / Load voltage L+ / permissible range, lower limit (DC)
28.8 VSupply voltage / Load voltage L+ / permissible range, upper limit (DC)

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7355-2SH00-0AE0
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Supply voltage / Load voltage L+ / permissible range, lower limit (DC)20.4 V
Supply voltage / Load voltage L+ / permissible range, upper limit (DC)28.8 V
Input current / from load voltage L+ (without load), max.270 mA; typ. 220 mA
Input current / from backplane bus 5 V DC, max.75 mA; typ. 50 mA
Power loss / Power loss, typ.5.5 W
Power loss / Power loss, max.6.9 W
Digital inputs / Number of digital inputs8
Digital inputs / Input characteristic curve in accordance with IEC 61131, type 2Yes
Digital inputs / Input voltage / Rated value (DC)24 V
Digital inputs / Input voltage / for signal "0"-3 to +5V
Digital inputs / Input voltage / for signal "1"13 to 30V
Digital inputs / Input current / for signal "1", typ.7 mA
Digital inputs / Cable length / shielded, max.1 000 m
Digital inputs / Cable length / unshielded, max.600 m
Digital outputs / Number of digital outputs8
Digital outputs / Short-circuit protectionYes; Electronic
Digital outputs / Limitation of inductive shutdown voltage toL+ (-1.5 V)
Digital outputs / Controlling a digital inputYes
Digital outputs / Switching capacity of the outputs / on lamp load, max.5 W
Digital outputs / Load resistance range / lower limit240 Ω
Digital outputs / Load resistance range / upper limit4 kΩ
Digital outputs / Output voltage / for signal "1", min.L+ (-2.5 V)
Digital outputs / Output current / for signal "1" rated value0.1 A
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.150 mA
Digital outputs / Output current / for signal "0" residual current, max.0.5 mA
Digital outputs / Parallel switching of two outputs / for logic linksYes
Digital outputs / Switching frequency / with resistive load, max.100 Hz
Digital outputs / Switching frequency / with inductive load, max.0.5 Hz
Digital outputs / Switching frequency / on lamp load, max.100 Hz
Digital outputs / Total current of the outputs (per group) / all mounting positions / up to 60 °C, max.400 mA
Digital outputs / Cable length / shielded, max.1 000 m
Digital outputs / Cable length / unshielded, max.600 m
Analog inputs / Number of analog inputs4
Analog inputs / permissible input voltage for voltage input (destruction limit),20 V
Analog inputs / permissible input current for current input (destruction limit),40 mA
Analog inputs / Input ranges / VoltageYes
Analog inputs / Input ranges / CurrentYes
Analog inputs / Input ranges / ThermocoupleYes
Analog inputs / Input ranges / Resistance thermometerYes
Analog inputs / Input ranges (rated values), voltages / 0 to +10 VYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (0 to 10 V)100 kΩ
Analog inputs / Input ranges (rated values), voltages / -1.75 V to +11.75 VYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (-1.75 V to +11.75 V)100 kΩ
Analog inputs / Input ranges (rated values), currents / 0 to 20 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 20 mA)50 Ω
Analog inputs / Input ranges (rated values), currents / 0 to 23.5 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 23.5 mA)50 Ω
Analog inputs / Input ranges (rated values), currents / -3.5 mA to +23.5 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (-3.5 mA to +23.5 mA)50 Ω
Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA)50 Ω
Analog inputs / Input ranges (rated values), thermocouples / Type BYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type B)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type EYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type E)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type JYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (type J)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type KYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type K)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type RYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type R)10 MΩ
Analog inputs / Input ranges (rated values), thermocouples / Type SYes
Analog inputs / Input ranges (rated values), thermocouples / Input resistance (Type S)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100Yes
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 100)10 MΩ
Analog inputs / Thermocouple (TC) / Temperature compensation / internal temperature compensationYes
Analog inputs / Thermocouple (TC) / Temperature compensation / external temperature compensation with Pt100Yes
Analog inputs / Characteristic linearization / ParameterizableYes
Analog inputs / Characteristic linearization / for thermocouplesType B, E, J, K, R, S
Analog inputs / Characteristic linearization / for resistance thermometerPt100 (standard)
Analog inputs / Cable length / shielded, max.200 m; 50 m at 80 mV and thermocouples
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.14 bit
Encoder / Connection of signal encoders / for voltage measurementYes
Encoder / Connection of signal encoders / for current measurement as 4-wire transducerYes
Encoder / Connectable encoders / 2-wire sensorYes
Encoder / Connectable encoders / permissible quiescent current (2-wire sensor), max.1.5 mA
Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-)0.06 %; ±0.06 to ±0.7%
Errors/accuracies / Operational error limit in overall temperature range / Current, relative to input range, (+/-)0.06 %; ±0.06 to ±0.7%
Errors/accuracies / Operational error limit in overall temperature range / Resistance thermometer, relative to input range, (+/-)0.06 %; ±0.06 to ±0.7%
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input range, (+/-)0.04 %; ±0.04 to ±0.5 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-)0.04 %; ±0.04 to ±0.5 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance thermometer, relative to input range, (+/-)0.04 %; ±0.04 to ±0.5 %
Interrupts/diagnostics/status information / Substitute values connectableYes; Parameterizable
Integrated Functions / Control technology / Number of closed-loop controllers4
Potential separation / Potential separation controller / between the channelsNo
Potential separation / Potential separation controller / between the channels and backplane busYes; Optocoupler
Isolation / Isolation tested with500 V DC
Connection method / required front connector2x 20-pin
Dimensions / Width80 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.470 g
Product type designationFM 355-2S

Connections and conditions of use

  • Digital inputs / Input voltage / for signal "0": -3 to +5V
  • Digital inputs / Input voltage / for signal "1": 13 to 30V
  • Digital inputs / Input current / for signal "1", typ.: 7 mA
  • Digital outputs / Output voltage / for signal "1", min.: L+ (-2.5 V)
  • Digital outputs / Output current / for signal "1" rated value: 0.1 A
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, min.: 5 mA
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.: 150 mA
  • Digital outputs / Output current / for signal "0" residual current, max.: 0.5 mA

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair