from 1 502,82 EUR Incl. VAT
6ES7336-1HE00-0AB0
- SIEMENS
- SIMATIC S7-300
- Analog Inputs
- 6ES7336-1HE00-0AB0
6ES7336-1HE00-0AB0
SIMATIC S7, Analog input SM 336, 6 AI; 14 bit; 40-pole, fail-safe analog inputs for SIMATIC S7F systems with diagnostic alarm More
Code: 6ES7336-1HE00-0AB0
SIMATIC S7, Analog input SM 336, 6 AI; 14 bit; 40-pole, fail-safe analog inputs for SIMATIC S7F systems with diagnostic alarm More
Code: 6ES7336-1HE00-0AB0
Part Sales 2
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7336-1HE00-0AB0 NC | 12/24 months | In external stock 8 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6ES7336-1HE00-0AB0 R | 12/24 months | In external stock 25 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7336-1HE00-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7336-1HE00-0AB0 – SIMATIC S7-300 module
Siemens SIMATIC S7-300 SIMATIC S7-300 module.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7336-1HE00-0AB0 |
| Product type designation | SIMATIC S7-300 module |
| Voltages and currents / Load voltage L+ / Rated value (DC) | 24 V |
| Voltages and currents / Load voltage L+ / reverse polarity protection | Yes |
| Current consumption / from backplane bus DC 5 V, max. | 90 mA |
| Current consumption / from supply voltage L+, max. | 160 mA; typically |
| Current consumption / Power loss, typ. | 4.25 W |
| Connection point / required front connectors | 40-pin |
| Analog inputs / Number of analog inputs | 6 |
| Analog inputs / Number of analog inputs for voltage measurement | 4 |
| Analog inputs / Cable length, shielded, max. | 200 m |
| Analog inputs / permissible input current for current input (destruction limit), max. | 40 mA |
| Analog inputs / Input ranges (rated values), voltages / 0 to +10 V | Yes |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / 4 to 20 mA | Yes |
| Analog value creation / Integrations and conversion time/resolutionper channel / Resolution with overload area (bit including sign), max. | 14 Bit |
| Analog value creation / Integrations and conversion time/resolutionper channel / Integration time, ms | 20 ms (at 50 Hz); 16.66 ms (at 60 Hz) |
| Analog value creation / Integrations and conversion time/resolutionper channel / Interference voltage suppression for interference frequency f1 in Hz | 38 dB |
| Encoder / Connection of signal encoders / for current measurement as 2-wire transducer | Yes |
| Encoder / Connection of signal encoders / for current measurement as 4-wire transducer | Yes |
| Errors/accuracies / Operational limit in overall temperature range / Voltage, relative to input area | +/- 0.48 % |
| Errors/accuracies / Operational limit in overall temperature range / Current, relative to input area | +/- 0.48 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input area | +/- 0.4 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input area | +/- 0.4 % |
| Status information/ alarms/diagnostics / Alarms / Diagnostic alarm | Yes; parameterizable |
| Diagnoses / Diagnostic information readable | Yes |
| Isolation / Isolation checked with | 500 V DC / 350 V AC |
| Isolation / Isolation, analog inputs / between the channels | No |
| Isolation / Isolation, analog inputs / between the channels and the backplane bus | Yes |
| Isolation / Isolation, analog inputs / between the channels and the voltage supply to the electronics | Yes; only if sensors are externally supplied |
| Dimensions and weight / Width | 80 mm |
| Dimensions and weight / Height | 125 mm |
| Dimensions and weight / Depth | 120 mm |
| Weights / Weight, approx. | 480 g |
Connections and conditions of use
- Connection point / required front connectors: 40-pin
- Encoder / Connection of signal encoders / for current measurement as 2-wire transducer: Yes
- Encoder / Connection of signal encoders / for current measurement as 4-wire transducer: Yes
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.