6ES7331-7PF11-0AB0

6ES7331-7PF11-0AB0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300, Analog input SM 331, isolated, 8 AI thermocouples Type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit, 50ms, 1x 40-pole More

Code: 6ES7331-7PF11-0AB0

from 647 EUR excl. VAT (782,87 EUR Incl. VAT)
Total in stock: 49 pcs External stock 49 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300, Analog input SM 331, isolated, 8 AI thermocouples Type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit, 50ms, 1x 40-pole More

Code: 6ES7331-7PF11-0AB0

Part Sales 3

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7331-7PF11-0AB0 NC 12/24 months In external stock 5 pcs
Within 2-4 days / Express
On request
New in open box (NO) 6ES7331-7PF11-0AB0 NO 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7331-7PF11-0AB0 R 12/24 months In external stock 43 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7331-7PF11-0AB0 O 3-6 weeks 24 months On request Enquire a repair

6ES7331-7PF11-0AB0 – SM 331

SIMATIC S7-300, analog input SM 331, isolated, 8 AI thermocouples type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit, 50 ms, 1x 40-pole

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Load voltage L+ / Rated value (DC)
YesSupply voltage / Load voltage L+ / Reverse polarity protection
8Analog inputs / Number of analog inputs

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7331-7PF11-0AB0
General information / Product function / Isochronous modeNo
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Supply voltage / Load voltage L+ / Reverse polarity protectionYes
Input current / from load voltage L+ (without load), max.240 mA
Input current / from backplane bus 5 V DC, max.100 mA
Power loss / Power loss, typ.3 W
Analog inputs / Number of analog inputs8
Analog inputs / permissible input voltage for voltage input (destruction limit),75 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)
Analog inputs / Constant measurement current for resistance-type transmitter,0.7 mA
Analog inputs / Input ranges / VoltageNo
Analog inputs / Input ranges / CurrentNo
Analog inputs / Input ranges / ThermocoupleYes
Analog inputs / Input ranges / Resistance thermometerNo
Analog inputs / Input ranges / ResistanceNo
Analog inputs / Input ranges (rated values), voltages / 0 to +10 VNo
Analog inputs / Input ranges (rated values), voltages / 1 V to 5 VNo
Analog inputs / Input ranges (rated values), voltages / 1 V to 10 VNo
Analog inputs / Input ranges (rated values), voltages / -1 V to +1 VNo
Analog inputs / Input ranges (rated values), voltages / -10 V to +10 VNo
Analog inputs / Input ranges (rated values), voltages / -2.5 V to +2.5 VNo
Analog inputs / Input ranges (rated values), voltages / -250 mV to +250 mVNo
Analog inputs / Input ranges (rated values), voltages / -5 V to +5 VNo
Analog inputs / Input ranges (rated values), voltages / -50 mV to +50 mVNo
Analog inputs / Input ranges (rated values), voltages / -500 mV to +500 mVNo
Analog inputs / Input ranges (rated values), voltages / -80 mV to +80 mVNo
Analog inputs / Input ranges (rated values), currents / 0 to 20 mANo
Analog inputs / Input ranges (rated values), currents / -10 mA to +10 mANo
Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mANo
Analog inputs / Input ranges (rated values), currents / -3.2 mA to +3.2 mANo
Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mANo
Analog inputs / Input ranges (rated values), thermocouples / Type BYes
Analog inputs / Input ranges (rated values), thermocouples / type CYes
Analog inputs / Input ranges (rated values), thermocouples / Type EYes
Analog inputs / Input ranges (rated values), thermocouples / Type JYes
Analog inputs / Input ranges (rated values), thermocouples / Type KYes
Analog inputs / Input ranges (rated values), thermocouples / Type LYes
Analog inputs / Input ranges (rated values), thermocouples / Type NYes
Analog inputs / Input ranges (rated values), thermocouples / Type RYes
Analog inputs / Input ranges (rated values), thermocouples / Type SYes
Analog inputs / Input ranges (rated values), thermocouples / Type TYes
Analog inputs / Input ranges (rated values), thermocouples / Type UYes
Analog inputs / Input ranges (rated values), thermocouples / Type TXK/TXK(L) to GOSTYes
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 10No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 1000No
Analog inputs / Input ranges (rated values), resistance thermometer / LG-Ni 1000No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 120No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 200No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 500No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 1000No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 200No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 500No
Analog inputs / Input ranges (rated values), resistors / 0 to 150 ohmsNo
Analog inputs / Input ranges (rated values), resistors / 0 to 300 ohmsNo
Analog inputs / Input ranges (rated values), resistors / 0 to 600 ohmsNo
Analog inputs / Input ranges (rated values), resistors / 0 to 6000 ohmsNo
Analog inputs / Thermocouple (TC) / Temperature compensation / ParameterizableYes
Analog inputs / Thermocouple (TC) / Temperature compensation / internal temperature compensationYes
Analog inputs / Thermocouple (TC) / Temperature compensation / external temperature compensation with Pt100Yes
Analog inputs / Thermocouple (TC) / Temperature compensation / external temperature compensation withYes
Analog inputs / Thermocouple (TC) / Temperature compensation / for definable comparison point temperatureYes
Analog inputs / Characteristic linearization / ParameterizableYes
Analog inputs / Characteristic linearization / for thermocouplesType B, E, J, K, L, N, R, S. T, U, C
Analog inputs / Cable length / shielded, max.100 m
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.16 bit; Two's complement
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizableYes
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic conversion time (ms)Up to 4 channels: 10 ms per module, 5 channels upwards: 190 ms per module
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference400 / 60 / 50 Hz
Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-)±1 K
Errors/accuracies / Operational error limit in overall temperature range / Thermocouple, relative to input range, (+/-)Type T: ±0.18%, Type U: ±0.15%, Type E: ±0.12%, Type J: ±0.12%, Type L: ±0.17%, Type K: ±0.15%, Type N: ±0.17%, Type R: ±0.08%, Type S: ±0.10%, Type B: ±0.13%, Type C: ±0.10%, TXK/XK(L): ±1.00% accuracy in the lower range of the characteristic curve
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Thermocouple, relative to input range, (+/-)Type T: ±0.13%, Type U: ±0.08%, Type E: ±0.05%, Type J: ±0.04%, Type L: ±0.06%, Type K: ±0.04%, Type N: ±0.04%, Type R: ±0.03%, Type S: ±0.03%, Type B: ±0.05%, Type C: ±0.02%, TXK/XK(L): ±0.67 % accuracy in the lower range of the characteristic curve
Interrupts/diagnostics/status information / Diagnostics functionYes; Parameterizable
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmYes; Parameterizable per group
Interrupts/diagnostics/status information / Alarms / Limit value alarmYes; Parameterizable
Interrupts/diagnostics/status information / Alarms / Hardware interruptYes; Parameterizable, channels 0 to 7
Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readableYes
Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red)Yes
Potential separation / Potential separation analog inputs / between the channelsYes
Potential separation / Potential separation analog inputs / between the channels, in groups of2
Potential separation / Potential separation analog inputs / between the channels and backplane busYes
Potential separation / Potential separation analog inputs / between the channels and the power supply of theYes
Isolation / Isolation tested with500 V DC
Connection method / required front connector40-pin
Dimensions / Width40 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.272 g
Product type designationSM 331
Number of poles40

Supported signals and ranges

  • Supply voltage / Load voltage L+ / Rated value (DC): 24 V
  • Supply voltage / Load voltage L+ / Reverse polarity protection: Yes
  • Input current / from load voltage L+ (without load), max.: 240 mA
  • Analog inputs / permissible input voltage for voltage input (destruction limit),: 75 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)
  • Analog inputs / Constant measurement current for resistance-type transmitter,: 0.7 mA
  • Analog inputs / Input ranges / Voltage: No
  • Analog inputs / Input ranges / Current: No
  • Analog inputs / Input ranges / Thermocouple: Yes

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair