from 729,63 EUR Incl. VAT
6ES7331-7PF11-0AB0
- SIEMENS
- SIMATIC S7-300
- Analog Inputs
- 6ES7331-7PF11-0AB0
6ES7331-7PF11-0AB0
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI thermocouples Type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit, 50ms, 1x 40-pole More
Code: 6ES7331-7PF11-0AB0
SIMATIC S7-300, Analog input SM 331, isolated, 8 AI thermocouples Type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit, 50ms, 1x 40-pole More
Code: 6ES7331-7PF11-0AB0
Part Sales 3
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6ES7331-7PF11-0AB0 NC | 12/24 months | In external stock 5 pcs |
Within 2-4 days / Express
|
On request
|
|
| New in open box (NO) | 6ES7331-7PF11-0AB0 NO | 12/24 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6ES7331-7PF11-0AB0 R | 12/24 months | In external stock 43 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7331-7PF11-0AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7331-7PF11-0AB0 – SM 331
SIMATIC S7-300, analog input SM 331, isolated, 8 AI thermocouples type B, E, J, K, L, N, R, S, T TXK/TXK (L) according to GOST 16 bit, 50 ms, 1x 40-pole
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7331-7PF11-0AB0 |
| General information / Product function / Isochronous mode | No |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Supply voltage / Load voltage L+ / Reverse polarity protection | Yes |
| Input current / from load voltage L+ (without load), max. | 240 mA |
| Input current / from backplane bus 5 V DC, max. | 100 mA |
| Power loss / Power loss, typ. | 3 W |
| Analog inputs / Number of analog inputs | 8 |
| Analog inputs / permissible input voltage for voltage input (destruction limit), | 75 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20) |
| Analog inputs / Constant measurement current for resistance-type transmitter, | 0.7 mA |
| Analog inputs / Input ranges / Voltage | No |
| Analog inputs / Input ranges / Current | No |
| Analog inputs / Input ranges / Thermocouple | Yes |
| Analog inputs / Input ranges / Resistance thermometer | No |
| Analog inputs / Input ranges / Resistance | No |
| Analog inputs / Input ranges (rated values), voltages / 0 to +10 V | No |
| Analog inputs / Input ranges (rated values), voltages / 1 V to 5 V | No |
| Analog inputs / Input ranges (rated values), voltages / 1 V to 10 V | No |
| Analog inputs / Input ranges (rated values), voltages / -1 V to +1 V | No |
| Analog inputs / Input ranges (rated values), voltages / -10 V to +10 V | No |
| Analog inputs / Input ranges (rated values), voltages / -2.5 V to +2.5 V | No |
| Analog inputs / Input ranges (rated values), voltages / -250 mV to +250 mV | No |
| Analog inputs / Input ranges (rated values), voltages / -5 V to +5 V | No |
| Analog inputs / Input ranges (rated values), voltages / -50 mV to +50 mV | No |
| Analog inputs / Input ranges (rated values), voltages / -500 mV to +500 mV | No |
| Analog inputs / Input ranges (rated values), voltages / -80 mV to +80 mV | No |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | No |
| Analog inputs / Input ranges (rated values), currents / -10 mA to +10 mA | No |
| Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mA | No |
| Analog inputs / Input ranges (rated values), currents / -3.2 mA to +3.2 mA | No |
| Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mA | No |
| Analog inputs / Input ranges (rated values), thermocouples / Type B | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / type C | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type E | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type J | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type K | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type L | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type N | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type R | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type S | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type T | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type U | Yes |
| Analog inputs / Input ranges (rated values), thermocouples / Type TXK/TXK(L) to GOST | Yes |
| Analog inputs / Input ranges (rated values), resistance thermometer / Cu 10 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 1000 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / LG-Ni 1000 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 120 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 200 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 500 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 1000 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 200 | No |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 500 | No |
| Analog inputs / Input ranges (rated values), resistors / 0 to 150 ohms | No |
| Analog inputs / Input ranges (rated values), resistors / 0 to 300 ohms | No |
| Analog inputs / Input ranges (rated values), resistors / 0 to 600 ohms | No |
| Analog inputs / Input ranges (rated values), resistors / 0 to 6000 ohms | No |
| Analog inputs / Thermocouple (TC) / Temperature compensation / Parameterizable | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / internal temperature compensation | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / external temperature compensation with Pt100 | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / external temperature compensation with | Yes |
| Analog inputs / Thermocouple (TC) / Temperature compensation / for definable comparison point temperature | Yes |
| Analog inputs / Characteristic linearization / Parameterizable | Yes |
| Analog inputs / Characteristic linearization / for thermocouples | Type B, E, J, K, L, N, R, S. T, U, C |
| Analog inputs / Cable length / shielded, max. | 100 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 16 bit; Two's complement |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizable | Yes |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic conversion time (ms) | Up to 4 channels: 10 ms per module, 5 channels upwards: 190 ms per module |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference | 400 / 60 / 50 Hz |
| Errors/accuracies / Operational error limit in overall temperature range / Voltage, relative to input range, (+/-) | ±1 K |
| Errors/accuracies / Operational error limit in overall temperature range / Thermocouple, relative to input range, (+/-) | Type T: ±0.18%, Type U: ±0.15%, Type E: ±0.12%, Type J: ±0.12%, Type L: ±0.17%, Type K: ±0.15%, Type N: ±0.17%, Type R: ±0.08%, Type S: ±0.10%, Type B: ±0.13%, Type C: ±0.10%, TXK/XK(L): ±1.00% accuracy in the lower range of the characteristic curve |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Thermocouple, relative to input range, (+/-) | Type T: ±0.13%, Type U: ±0.08%, Type E: ±0.05%, Type J: ±0.04%, Type L: ±0.06%, Type K: ±0.04%, Type N: ±0.04%, Type R: ±0.03%, Type S: ±0.03%, Type B: ±0.05%, Type C: ±0.02%, TXK/XK(L): ±0.67 % accuracy in the lower range of the characteristic curve |
| Interrupts/diagnostics/status information / Diagnostics function | Yes; Parameterizable |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | Yes; Parameterizable per group |
| Interrupts/diagnostics/status information / Alarms / Limit value alarm | Yes; Parameterizable |
| Interrupts/diagnostics/status information / Alarms / Hardware interrupt | Yes; Parameterizable, channels 0 to 7 |
| Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readable | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red) | Yes |
| Potential separation / Potential separation analog inputs / between the channels | Yes |
| Potential separation / Potential separation analog inputs / between the channels, in groups of | 2 |
| Potential separation / Potential separation analog inputs / between the channels and backplane bus | Yes |
| Potential separation / Potential separation analog inputs / between the channels and the power supply of the | Yes |
| Isolation / Isolation tested with | 500 V DC |
| Connection method / required front connector | 40-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 272 g |
| Product type designation | SM 331 |
| Number of poles | 40 |
Supported signals and ranges
- Supply voltage / Load voltage L+ / Rated value (DC): 24 V
- Supply voltage / Load voltage L+ / Reverse polarity protection: Yes
- Input current / from load voltage L+ (without load), max.: 240 mA
- Analog inputs / permissible input voltage for voltage input (destruction limit),: 75 V; 20 V DC permanent, 75 V DC for max. 1 s (duty factor 1:20)
- Analog inputs / Constant measurement current for resistance-type transmitter,: 0.7 mA
- Analog inputs / Input ranges / Voltage: No
- Analog inputs / Input ranges / Current: No
- Analog inputs / Input ranges / Thermocouple: Yes
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.