6ES7326-2BF01-0AB0

6ES7326-2BF01-0AB0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7, Digital output SM 326, 10 DO, 24 V DC, 2A, fail-safe digital output for SIMATIC S7F systems, with diagnostic alarm, 1x 40-pole More

Code: 6ES7326-2BF01-0AB0

from 560 EUR excl. VAT (677,60 EUR Incl. VAT)
Total in stock: 66 pcs External stock 66 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7, Digital output SM 326, 10 DO, 24 V DC, 2A, fail-safe digital output for SIMATIC S7F systems, with diagnostic alarm, 1x 40-pole More

Code: 6ES7326-2BF01-0AB0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6ES7326-2BF01-0AB0 NC 12/24 months In external stock 25 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6ES7326-2BF01-0AB0 R 12/24 months In external stock 41 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7326-2BF01-0AB0 O 3-6 weeks 24 months On request Enquire a repair

6ES7326-2BF01-0AB0 – SIMATIC S7-300 module

Siemens SIMATIC S7-300 SIMATIC S7-300 module.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
10Digital outputs / Number of digital outputs
1,000 m; 200 m for SIL3, AK 6, Cat 4Digital outputs / Cable length, shielded, max.
600 mDigital outputs / Cable length unshielded, max.

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7326-2BF01-0AB0
Product type designationSIMATIC S7-300 module
Voltages and currents / Load voltage L+ / Rated value (DC)24 V; 1L+, 2L+, 3L+
Current consumption / from load voltage1L+, max.70 mA; from supply voltage
Current consumption / from load voltage 2L+ (without load), max.100 mA
Current consumption / from load voltage 3L+ (without load), max.100 mA
Current consumption / from backplane bus DC 5 V, max.100 mA
Current consumption / Power loss, typ.12 W
Connection point / required front connectors40-pin
Digital outputs / Number of digital outputs10
Digital outputs / Cable length, shielded, max.1,000 m; 200 m for SIL3, AK 6, Cat 4
Digital outputs / Cable length unshielded, max.600 m
Digital outputs / Short-circuit protection of the outputYes; electronic
Digital outputs / Limitation of inductive shutdown voltage toL+ (-53 V) without series diode, L+ (-33 V) with series diode
Digital outputs / Lamp load, max.5 W
Digital outputs / Output voltage / for signal "1" with series diode, min.L+ (-1.8 V)
Digital outputs / Output voltage / for signal "1" without series diode, min.L+ (-1.0 V)
Output current / for signal "1" rated value2 A
Output current / for signal "1" permissible range for 0 to 40 °C, min.7 mA
Output current / for signal "1" permissible range for 0 to 40 °C, max.2 A; 2 A for horizontal installation, 1 A for vertical installation
Output current / for signal "1" permissible range for 40 to 60 °C, min.7 mA
Output current / for signal "1" permissible range for 40 to 60 °C, max.1 A; for horizontal installation
Output current / for signal "0" residual current, max.0.5 mA
Switching frequency / with resistive load, max.10 Hz
Switching frequency / with inductive load, max.2 Hz
Switching frequency / on lamp load, max.10 Hz
Aggregate current of the outputs (per group) / vertical installation / up to 40 °C, max.5 A; without series diode, 4 A with series diode
Aggregate current of the outputs (per group) / horizontal installation / up to 40 °C, max.7.5 A; without series diode, 5 A with series diode
Aggregate current of the outputs (per group) / horizontal installation / up to 60 °C, max.5 A; without series diode, 4 A with series diode
Status information/ alarms/diagnostics / Alarms / Diagnostic alarmYes
Status information/ alarms/diagnostics / Diagnoses / Diagnostic information readableYes
Isolation / Isolation checked with500 V DC / 350 V AC
Isolation / Isolation, digital outputs / between the channelsYes
Isolation / Isolation, digital outputs / between the channels, in groups of5
Isolation / Isolation, digital outputs / between the channels and the backplane busYes
Isolation / Isolation, digital outputs / between the channels and the voltage supply to the electronicsYes
Dimensions and weight / Width80 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth120 mm
Weights / Weight, approx.465 g

Connections and conditions of use

  • Connection point / required front connectors: 40-pin
  • Digital outputs / Output voltage / for signal "1" with series diode, min.: L+ (-1.8 V)
  • Digital outputs / Output voltage / for signal "1" without series diode, min.: L+ (-1.0 V)
  • Output current / for signal "1" rated value: 2 A
  • Output current / for signal "1" permissible range for 0 to 40 °C, min.: 7 mA
  • Output current / for signal "1" permissible range for 0 to 40 °C, max.: 2 A; 2 A for horizontal installation, 1 A for vertical installation
  • Output current / for signal "1" permissible range for 40 to 60 °C, min.: 7 mA
  • Output current / for signal "1" permissible range for 40 to 60 °C, max.: 1 A; for horizontal installation

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair