6ES7174-0AA00-0AA0

6ES7174-0AA00-0AA0

Sales, Repair, Purchase

SIEMENS

SIMATIC S7-300,INTERFACE MODULE IM174, FOR CONNECTING ANALOG DRIVES AND STEP DRIVES VIA ISOCHRONUS PROFIBUS TO MOTION CONTROLLERS 4 CHANNELS (4 ENCOD.INP., 4 AO) CONFIGURABLE WITH S7-TECHNOLOGY V3.0SP1 OR HIGHER
More

Code: 6ES7174-0AA00-0AA0

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIMATIC S7-300,INTERFACE MODULE IM174, FOR CONNECTING ANALOG DRIVES AND STEP DRIVES VIA ISOCHRONUS PROFIBUS TO MOTION CONTROLLERS 4 CHANNELS (4 ENCOD.INP., 4 AO) CONFIGURABLE WITH S7-TECHNOLOGY V3.0SP1 OR HIGHER
More

Code: 6ES7174-0AA00-0AA0

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6ES7174-0AA00-0AA0 O 3-6 weeks 24 months On request Enquire a repair

6ES7174-0AA00-0AA0 – IM 174

Siemens SIMATIC S7-300 IM 174.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
YesSupply voltages / Rated value / DC 24 V
20.4 VSupply voltages / Rated value / permissible range, lower limit (DC)
28.8 VSupply voltages / Rated value / permissible range, upper limit (DC)

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6ES7174-0AA00-0AA0
Product type designationIM 174
Supply voltages / Rated value / DC 24 VYes
Supply voltages / Rated value / permissible range, lower limit (DC)20.4 V
Supply voltages / Rated value / permissible range, upper limit (DC)28.8 V
Current consumption / Current consumption, max.500 mA
Current consumption / Power loss, typ.12 W
Connection point / required front connectors40-pin
Isochronous mode / Isochronouos modeYes
Isochronous mode / shortest clock pulse1.5 ms
Digital inputs / Number of digital inputs10
Digital inputs / Cable length / Cable length, shielded, max.100 m
Digital inputs / Input voltage / for signal "0"3 to 5 V
Digital inputs / Input voltage / for signal "1"15 to 30 V
Digital inputs / Input current / for signal "0", max. (permissible quiescent current)3 mA
Digital inputs / Input current / for signal "1", typ.6 mA
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at " to "1", min.15 µs
Digital outputs / Number of digital outputs8
Digital outputs / Cable length, shielded, max.600 m
Digital outputs / Short-circuit protection of the outputYes
Switching capacity of the outputs / with resistive load, max.0.5 A
Switching capacity of the outputs / on lamp load, max.5 W
Output voltage / Rated value (DC)24 V; L+
Output voltage / for signal "1", min.L+ (-3 V)
Output voltage / for signal "1" (DC), max.24 V; max. value is equal to feed L+
Output current / for signal "1" permissible range for 0 to 60 °C, min.5 mA
Output current / for signal "1" permissible range for 0 to 60 °C, max.500 mA
Output current / for signal "0" residual current, max.0.4 mA
Output delay with resistive load / "0" to "1", max.500 µs
Switching frequency / with resistive load, max.100 Hz
Switching frequency / with inductive load, max.1 Hz
Relay outputs / Number of operating cycles500,000
Relay outputs / Switching capacity of the contacts / with resistive load, max.1 A
Analog outputs / Number of anlog outputs4
Analog outputs / Output ranges, voltage / 10 to +10 VYes
Analog value creation / Integrations and conversion time/resolutionper channel / Resolution with overload area (bit including sign), max.15 Bit
Encoder supply / 5 V encoder supply / 5 VYes
Encoder supply / 5 V encoder supply / Output current, max.1.2 A
Encoder supply / 24 V encoder supply / 24 VYes
Encoder supply / 24 V encoder supply / Output current, max.1.4 A
Encoder supply / Absolute encoder (SSI) encoder supply / Absolute encoder (SSI)Yes
Encoder supply / Absolute encoder (SSI) encoder supply / Short-circuit protectionYes
Encoder / Number of connectable encoders, max.4
Encoder / Connectable encoders / Incremental encoder (symmetrical)Yes
Encoder / Connectable encoders / Absolute encoder (SSI)Yes
Encoder / Encoder signals, incremental encoder (symmetrical) / Trace mark signalsA, notA, B, notB
Encoder / Encoder signals, incremental encoder (symmetrical) / Zero mark signalN, notN
Encoder / Encoder signals, incremental encoder (symmetrical) / Input frequency, max.1 MHz
Encoder / Encoder signals, incremental encoder (symmetrical) / Cable length, shielded, max.35 m; 35 m at max. 500 kHz; 10 m at max. 1 MHz
Encoder signals, absolute encoder (SSI) / Data signalDATA, notDATA
Encoder signals, absolute encoder (SSI) / Clock signalCLS, notCLS
Encoder signals, absolute encoder (SSI) / Telegram length13, 21, 25 bit
Encoder signals, absolute encoder (SSI) / Clock frequency, max.3 MHz; 187.5 KHz to 3.0 MHz (parameterizable)
Encoder signals, absolute encoder (SSI) / Gray codeYes
Encoder signals, absolute encoder (SSI) / Cable length, shielded, max.250 m; 250 m at 187.5 kHz, 10 m at 1.5 MHz
Isolation / Isolation, digital outputs / Galvanic isolation, digital outputsYes
Isolation / Galvanic isolation, digital inputs / galvanic isolation, digital inputsYes
Dimensions and weight / Width160 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth118 mm
Weights / Weight, approx.1 kg

Connections and conditions of use

  • Connection point / required front connectors: 40-pin
  • Digital inputs / Input voltage / for signal "0": 3 to 5 V
  • Digital inputs / Input voltage / for signal "1": 15 to 30 V
  • Digital inputs / Input current / for signal "0", max. (permissible quiescent current): 3 mA
  • Digital inputs / Input current / for signal "1", typ.: 6 mA
  • Output voltage / for signal "1", min.: L+ (-3 V)
  • Output voltage / for signal "1" (DC), max.: 24 V; max. value is equal to feed L+
  • Output current / for signal "1" permissible range for 0 to 60 °C, min.: 5 mA

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair