6ES7 322-1BF01-0AA0
- SIEMENS
- SIMATIC S7-300
- Digital Outputs
- 6ES7 322-1BF01-0AA0
6ES7 322-1BF01-0AA0
SIMATIC S7-300, digital output SM 322, isolated, 8 DO, 24 V DC, 2 A, 1x 20-pole
More
Code: 6ES7 322-1BF01-0AA0
SIMATIC S7-300, digital output SM 322, isolated, 8 DO, 24 V DC, 2 A, 1x 20-pole
More
Code: 6ES7 322-1BF01-0AA0
Part Sales 1
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| Used (U) | 6ES7 322-1BF01-0AA0 U | 3 months | In external stock 4 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6ES7 322-1BF01-0AA0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6ES7322-1BF01-0AA0 – SM 322
SIMATIC S7-300, digital output SM 322, isolated, 8 DO, 24 V DC, 2 A, 1x 20-pole
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6ES7322-1BF01-0AA0 |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Supply voltage / Load voltage L+ / permissible range, lower limit (DC) | 20.4 V |
| Supply voltage / Load voltage L+ / permissible range, upper limit (DC) | 28.8 V |
| Input current / from load voltage L+ (without load), max. | 60 mA |
| Input current / from backplane bus 5 V DC, max. | 40 mA |
| Power loss / Power loss, typ. | 6.8 W |
| Digital outputs / Number of digital outputs | 8 |
| Digital outputs / Short-circuit protection | Yes; Electronic |
| Digital outputs / Response threshold, typ. | 3 A |
| Digital outputs / Limitation of inductive shutdown voltage to | L+ (-48 V) |
| Digital outputs / Controlling a digital input | Yes |
| Digital outputs / Switching capacity of the outputs / on lamp load, max. | 10 W |
| Digital outputs / Load resistance range / lower limit | 12 Ω |
| Digital outputs / Load resistance range / upper limit | 4 kΩ |
| Digital outputs / Output voltage / for signal "1", min. | L+ (-0.8 V) |
| Digital outputs / Output current / for signal "1" rated value | 2 A |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min. | 5 mA |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max. | 2.4 A |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min. | 5 mA |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max. | 2.4 A |
| Digital outputs / Output current / for signal "1" minimum load current | 5 mA |
| Digital outputs / Output current / for signal "0" residual current, max. | 0.5 mA |
| Digital outputs / Output delay with resistive load / "0" to "1", max. | 100 µs |
| Digital outputs / Output delay with resistive load / "1" to "0", max. | 500 µs |
| Digital outputs / Parallel switching of two outputs / for uprating | No |
| Digital outputs / Parallel switching of two outputs / for redundant control of a load | Yes |
| Digital outputs / Switching frequency / with resistive load, max. | 100 Hz |
| Digital outputs / Switching frequency / with inductive load, max. | 0.5 Hz |
| Digital outputs / Switching frequency / with inductive load (acc. to IEC 60947-5-1, DC13), max. | 0.5 Hz |
| Digital outputs / Switching frequency / on lamp load, max. | 10 Hz |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 40 °C, max. | 4 A |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 60 °C, max. | 4 A |
| Digital outputs / Total current of the outputs (per group) / vertical installation / up to 40 °C, max. | 4 A |
| Digital outputs / Cable length / shielded, max. | 1 000 m |
| Digital outputs / Cable length / unshielded, max. | 600 m |
| Interrupts/diagnostics/status information / Alarms | No |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | No |
| Interrupts/diagnostics/status information / Diagnoses / Wire break | No |
| Interrupts/diagnostics/status information / Diagnoses / Short-circuit | No |
| Interrupts/diagnostics/status information / Diagnoses / Fuse blown | No |
| Interrupts/diagnostics/status information / Diagnoses / Missing load voltage | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Rated load voltage PWR (green) | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Fuse OK FSG (green) | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital output (green) | Yes; per channel |
| Potential separation / Potential separation digital outputs / between the channels | Yes |
| Potential separation / Potential separation digital outputs / between the channels, in groups of | 4 |
| Potential separation / Potential separation digital outputs / between the channels and backplane bus | Yes; Optocoupler |
| Isolation / Isolation tested with | 500 V DC |
| Connection method / required front connector | 20-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 190 g |
| Product type designation | SM 322 |
| Number of poles | 20 |
Connections and conditions of use
- Digital outputs / Output voltage / for signal "1", min.: L+ (-0.8 V)
- Digital outputs / Output current / for signal "1" rated value: 2 A
- Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.: 5 mA
- Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.: 2.4 A
- Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.: 5 mA
- Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.: 2.4 A
- Digital outputs / Output current / for signal "1" minimum load current: 5 mA
- Digital outputs / Output current / for signal "0" residual current, max.: 0.5 mA
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.