6EP1935-6MD31
- SIEMENS
- SITOP POWER SUPPLIES
- 6EP1935-6MD31
6EP1935-6MD31
SITOP pure lead-acid battery module 24 V/2.5 Ah with maintenance-free sealed lead-acid batteries for SITOP DC UPS module 6 A and 15 A More
Code: 6EP1935-6MD31
SITOP pure lead-acid battery module 24 V/2.5 Ah with maintenance-free sealed lead-acid batteries for SITOP DC UPS module 6 A and 15 A More
Code: 6EP1935-6MD31
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6EP1935-6MD31 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6EP1935-6MD31 – Battery module
SITOP Battery module/24V/2.5AH SITOP pure lead-acid battery module 24 V/2.5 Ah with maintenance-free sealed lead-acid batteries for SITOP DC UPS module 6 A and 15 A
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6EP1935-6MD31 |
| General information / product type designation | Battery module |
| General information / product designation | Battery module 2.5 Ah |
| General information / type of battery | maintenance-free pure lead batteries |
| General information / product version | Extension module/battery module |
| electrical data / end-of-charge voltage at DC / at -10 °C recommended | 29 V |
| electrical data / end-of-charge voltage at DC / at 0 °C recommended | 28.6 V |
| electrical data / end-of-charge voltage at DC / at 20 °C recommended | 27.9 V |
| electrical data / end-of-charge voltage at DC / at 30 °C recommended | 27.5 V |
| electrical data / end-of-charge voltage at DC / at 40 °C recommended | 27.2 V |
| electrical data / end-of-charge voltage at DC / at 50 °C recommended | 26.8 V |
| electrical data / end-of-charge voltage at DC / at 60 °C recommended | 26.4 V |
| output / battery capacity | 2.5 A·h |
| output / output current in buffering mode maximum | 15 A |
| output / peak current | 15 A |
| output / charging current maximum | 5 A |
| output / output voltage at DC rated value | 24 V |
| interfaces / communication function | No |
| protection and monitoring / design of short-circuit protection | Battery fuse 15 A/32 V (solid-state circuitry blade-type fuse + support) |
| protection and monitoring / design of the overload protection | Valve control |
| safety / operating resource protection class | Class III |
| safety / protection class IP | IP00 |
| ambient conditions / ambient condition | For storage, mounting and operation of lead-acid batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. You must ensure that the battery site is sufficiently ventilated. Possible sources of ignition must be at least 50 cm away. |
| ambient conditions / ambient temperature / during operation | -40 ... +60 °C |
| ambient conditions / ambient temperature / during transport | -40 ... +60 °C |
| ambient conditions / ambient temperature / during storage | -40 ... +60 °C |
| ambient conditions / relative temporary capacity loss at 20 °C in a month typical | 3 % |
| service life / service life of energy storage / typical | capacity falls to 80 % of original capacity (according to EUROBAT) |
| service life / service life of energy storage / at 20 °C typical | 10 a |
| service life / service life of energy storage / at 30 °C typical | 7 a |
| service life / service life of energy storage / at 40 °C typical | 3 a |
| service life / service life of energy storage / at 50 °C typical | 1.5 a |
| service life / service life of energy storage / at 60 °C typical | 1 a |
| service life / note | Along with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature range 0 to +20 °C. |
| connection method / type of electrical connection | spring-loaded terminals |
| connection method / for UPS module | 1 screw terminal each for 0.08 ... 2.5 mm² for + BAT and - BAT |
| mechanical data / width × height × depth of the enclosure | 265 × 151 × 91 mm |
| mechanical data / installation width × mounting height | 285 mm × 171 mm |
| mechanical data / fastening method | snaps onto DIN rail EN 60715 35x15 or keyhole mounting for hooking in to M4 screws |
| mechanical data / DIN-rail mounting | Yes |
| mechanical data / S7 rail mounting | No |
| mechanical data / wall mounting | Yes |
| mechanical data / net weight | 3.8 kg |
| mechanical data / number of cells | 12 |
| accessories / product component included | Accessories pack with solid-state circuitry fuse 15 A |
Connections and conditions of use
- output / peak current: 15 A
- interfaces / communication function: No
- connection method / type of electrical connection: spring-loaded terminals
- connection method / for UPS module: 1 screw terminal each for 0.08 ... 2.5 mm² for + BAT and - BAT
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.