6AG2212-1AE40-1XB0
- SIEMENS
- SIMATIC ET 200 / DP
- 6AG2212-1AE40-1XB0
6AG2212-1AE40-1XB0
SIPLUS S7-1200 CPU 1212C DC/DC/DC T1 rail based on 6ES7212-1AE40-0XB0 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), compact CPU, DC/DC/DC, onboard I/O: 8 DI 24 V DC 6 DQ 24 V DC 2 AI 0-10 V DC, power supply: 20.4-28.8 V DC program/data memory 50 KB More
Code: 6AG2212-1AE40-1XB0
SIPLUS S7-1200 CPU 1212C DC/DC/DC T1 rail based on 6ES7212-1AE40-0XB0 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), compact CPU, DC/DC/DC, onboard I/O: 8 DI 24 V DC 6 DQ 24 V DC 2 AI 0-10 V DC, power supply: 20.4-28.8 V DC program/data memory 50 KB More
Code: 6AG2212-1AE40-1XB0
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG2212-1AE40-1XB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG2212-1AE40-1XB0 – CPU 1212C DC/DC/DC
Siemens 6AG2212-1AE40-1XB0: SIPLUS S7-1200 CPU 1212C DC/DC/DC T1 rail based on 6ES7212-1AE40-0XB0 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), compact CPU, DC/DC/DC, onboard I/O: 8 DI 24 V DC 6 DQ 24 V DC 2 AI 0-10 V DC, power supply: 20.4-28.8 V DC program/data memory 50 KB.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG2212-1AE40-1XB0 |
| Product type | CPU 1212C DC/DC/DC |
| Supply voltage / Rated value (DC) / 24 V DC | Yes |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Input current / Current consumption (rated value) | 400 mA; Typical |
| Work memory / integrated | 100 kbyte |
| Digital inputs / Number of digital inputs | 8; Integrated |
| Digital inputs / Input voltage / Rated value (DC) | 24 V |
| Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / parameterizable | 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms |
| Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", min. | 0.2 ms |
| Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", max. | 12.8 ms |
| Digital inputs / Input delay (for rated value of input voltage) / for technological functions / Parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
| Digital inputs / Cable length / shielded, max. | 500 m; 50 m for technological functions |
| Digital inputs / Cable length / unshielded, max. | 300 m; for technological functions: No |
| Digital outputs / Number of digital outputs | 6 |
| Digital outputs / Output current / for signal "1" rated value | 0.5 A |
| Digital outputs / Cable length / shielded, max. | 500 m |
| Digital outputs / Cable length / unshielded, max. | 150 m |
| Analog inputs / Number of analog inputs | 2 |
| Analog inputs / Input ranges (rated values), voltages / 0 to +10 V | Yes |
| Analog inputs / Input ranges (rated values), voltages / Input resistance (0 to 10 V) | ≥100k ohms |
| Analog inputs / Cable length / shielded, max. | 100 m; twisted and shielded |
| Analog outputs / Number of analog outputs | 0 |
| Ambient temperature during operation / horizontal installation, min. | -25 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation / horizontal installation, max. | 60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155); number of simultaneously switched on inputs or outputs: 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical |
| Ambient temperature during operation / vertical installation, min. | -25 °C; = Tmin |
| Ambient temperature during operation / vertical installation, max. | 50 °C; = Tmax |
| Width | 90 mm |
| Height | 100 mm |
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.