6AG1405-0KA02-7AA0
SIPLUS S7-400 PS 405 10 A based on 6ES7405-0KA02-0AA0 with conformal coating, -25…+70 °C, power supply, wide range 10 A, 24/48/60 V DC; 5 V DC/10 A More
Code: 6AG1405-0KA02-7AA0
SIPLUS S7-400 PS 405 10 A based on 6ES7405-0KA02-0AA0 with conformal coating, -25…+70 °C, power supply, wide range 10 A, 24/48/60 V DC; 5 V DC/10 A More
Code: 6AG1405-0KA02-7AA0
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1405-0KA02-7AA0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1405-0KA02-7AA0
Siemens 6AG1405-0KA02-7AA0: SIPLUS S7-400 PS 405 10 A based on 6ES7405-0KA02-0AA0 with conformal coating, -25…+70 °C, power supply, wide range 10 A, 24/48/60 V DC; 5 V DC/10 A.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1405-0KA02-7AA0 |
| Supply voltage / Rated value (DC) / 24 V DC | Yes |
| Supply voltage / Rated value (DC) / 48 V DC | Yes |
| Supply voltage / Rated value (DC) / 60 V DC | Yes |
| Supply voltage / Mains buffering / Mains/voltage failure stored energy time | 20 ms |
| Supply voltage / Mains buffering / Mains buffering according to NAMUR recommendation | Yes |
| Input current / Rated value at 24 V DC | 4 A |
| Input current / Rated value at 48 V DC | 2 A |
| Input current / Rated value at 60 V DC | 1.6 A |
| Input current / Inrush current, max. | 18 A; Full width at half maximum 20 ms |
| Output voltage / Type of output voltage | DC |
| Output voltage / Rated value (DC) / 5 V DC | Yes |
| Output voltage / Rated value (DC) / 24 V DC | Yes |
| Output current / for backplane bus (5 V DC), max. | 10 A; no base load required |
| Output current / for backplane bus (24 V DC), max. | 1 A; idling-proof |
| Output current / Short-circuit protection | Yes |
| Power loss / Power loss, typ. | 20 W |
| Potential separation / primary/secondary | Yes |
| Ambient temperature during operation / min. | -25 °C; = Tmin |
| Ambient temperature during operation / max. | 70 °C; = Tmax |
| Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m |
| Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
| Width | 50 mm |
| Height | 290 mm |
| Depth | 217 mm |
| Weights / Weight, approx. | 1 200 g |
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.