6AG1326-2BF10-2AB0
- SIEMENS
- SIMATIC ET 200 / DP
- 6AG1326-2BF10-2AB0
6AG1326-2BF10-2AB0
SIPLUS S7-300 SM 326 10F-DQ based on 6ES7326-2BF10-0AB0 with conformal coating, -25ÔǪ+60 -¦C, 70-¦ with forced convection, digital output 24 V DC/2A PP, fail-safe digital output for SIMATIC S7F systems, with diagnostic alarm, LVV, 1x 40-pole More
Code: 6AG1326-2BF10-2AB0
SIPLUS S7-300 SM 326 10F-DQ based on 6ES7326-2BF10-0AB0 with conformal coating, -25ÔǪ+60 -¦C, 70-¦ with forced convection, digital output 24 V DC/2A PP, fail-safe digital output for SIMATIC S7F systems, with diagnostic alarm, LVV, 1x 40-pole More
Code: 6AG1326-2BF10-2AB0
Part Sales 2
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| New in sealed box (NC) | 6AG1326-2BF10-2AB0 NC | 12/24 months | In external stock 1 pcs |
Within 2-4 days / Express
|
On request
|
|
| Refurbished (R) | 6AG1326-2BF10-2AB0 R | 12/24 months | In external stock 2 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1326-2BF10-2AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1326-2BF10-2AB0
Siemens 6AG1326-2BF10-2AB0: SIPLUS S7-300 SM 326 10 F-DO based on 6ES7326-2BF10-0AB0 with conformal coating, -25…+60 °C, 70° with forced convection, digital output 24 V DC/2 A PP, fail-safe digital output for SIMATIC S7F systems, with diagnostic alarm, LVV, 1x 40-pole.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1326-2BF10-2AB0 |
| Supply voltage / Rated value (DC) | 24 V; 1L+ |
| Supply voltage / Reverse polarity protection | Yes |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V; 2L+, 3L+ |
| Supply voltage / Load voltage L+ / Reverse polarity protection | No |
| Input current / from supply voltage 1L+, max. | 100 mA |
| Input current / from load voltage 2L+ (without load), max. | 100 mA |
| Input current / from load voltage 3L+ (without load), max. | 100 mA |
| Input current / from backplane bus 5 V DC, max. | 100 mA |
| Power loss / Power loss, typ. | 6 W |
| Digital outputs / Number of digital outputs | 10 |
| Digital outputs / Switching capacity of the outputs / on lamp load, max. | 5 W |
| Digital outputs / Output current / for signal "1" rated value | 2 A |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min. | 7 mA |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max. | 2.4 A |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min. | 7 mA |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max. | 2.4 A |
| Digital outputs / Output current / for signal "0" residual current, max. | 0.5 mA |
| Digital outputs / Cable length / shielded, max. | 1 000 m |
| Digital outputs / Cable length / unshielded, max. | 600 m |
| Potential separation / Potential separation digital outputs / between the channels | Yes |
| Potential separation / Potential separation digital outputs / between the channels, in groups of | 5 |
| Potential separation / Potential separation digital outputs / between the channels and backplane bus | Yes |
| Ambient temperature during operation / min. | -25 °C |
| Ambient temperature during operation / max. | 60 °C; = T max; *+70 °C when forced convection at a minimum air speed of 0.3 m/s through the modules is ensured. If in the course of maintenance or automatic diagnosis it is determined that the admissible specified parameters have been exceeded, the modules should be subjected to a proof test (function check) by the manufacturer. |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Weights / Weight, approx. | 330 g |
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.