6AG1322-1BL00-2AA0
- SIEMENS
- SIMATIC ET 200 / DP
- 6AG1322-1BL00-2AA0
6AG1322-1BL00-2AA0
SIPLUS S7-300 SM 322 32DQ 40-pole based on 6ES7322-1BL00-0AA0 with conformal coating, -25ÔǪ+70 -¦C, digital output isolated, 32 DQ, 24 V DC, 0.5 A, 1x 40-pole, total current 4 A/group (16 A/module) More
Code: 6AG1322-1BL00-2AA0
SIPLUS S7-300 SM 322 32DQ 40-pole based on 6ES7322-1BL00-0AA0 with conformal coating, -25ÔǪ+70 -¦C, digital output isolated, 32 DQ, 24 V DC, 0.5 A, 1x 40-pole, total current 4 A/group (16 A/module) More
Code: 6AG1322-1BL00-2AA0
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1322-1BL00-2AA0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1322-1BL00-2AA0 – SM 322
SIPLUS S7-300 SM 322 32 DO 40-pole based on 6ES7322- 1BL00-0AA0 with conformal coating, -25…+70 °C, digital output isolated, 32 DO, 24 V DC, 0.5 A, 1x 40-pole, total current 4 A/group (16 A/module)
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1322-1BL00-2AA0 |
| General information / based on | 6ES7322-1BL00-0AA0 |
| Supply voltage / Load voltage L+ / Rated value (DC) | 24 V |
| Supply voltage / Load voltage L+ / permissible range, lower limit (DC) | 20.4 V |
| Supply voltage / Load voltage L+ / permissible range, upper limit (DC) | 28.8 V |
| Input current / from load voltage L+ (without load), max. | 160 mA |
| Input current / from backplane bus 5 V DC, max. | 110 mA |
| Power loss / Power loss, typ. | 6.6 W |
| Digital outputs / Number of digital outputs | 32 |
| Digital outputs / Short-circuit protection | Yes; Electronic |
| Digital outputs / Response threshold, typ. | 1 A |
| Digital outputs / Limitation of inductive shutdown voltage to | L+ (-53 V) |
| Digital outputs / Controlling a digital input | Yes |
| Digital outputs / Switching capacity of the outputs / on lamp load, max. | 5 W |
| Digital outputs / Load resistance range / lower limit | 48 Ω |
| Digital outputs / Load resistance range / upper limit | 4 kΩ |
| Digital outputs / Output voltage / for signal "1", min. | L+ (-0.8 V) |
| Digital outputs / Output current / for signal "1" rated value | 0.5 A |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min. | 5 mA |
| Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max. | 0.6 A |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min. | 5 mA |
| Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max. | 0.6 A |
| Digital outputs / Output current / for signal "1" minimum load current | 5 mA |
| Digital outputs / Output current / for signal "0" residual current, max. | 0.5 mA |
| Digital outputs / Output delay with resistive load / "0" to "1", max. | 100 µs |
| Digital outputs / Output delay with resistive load / "1" to "0", max. | 500 µs |
| Digital outputs / Parallel switching of two outputs / for uprating | No |
| Digital outputs / Parallel switching of two outputs / for redundant control of a load | Yes; only outputs of the same group |
| Digital outputs / Switching frequency / with resistive load, max. | 100 Hz |
| Digital outputs / Switching frequency / with inductive load (acc. to IEC 60947-5-1, DC13), max. | 0.5 Hz |
| Digital outputs / Switching frequency / on lamp load, max. | 10 Hz |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 40 °C, max. | 4 A |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 60 °C, max. | 3 A |
| Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 70 °C, max. | 2 A |
| Digital outputs / Total current of the outputs (per group) / vertical installation / up to 40 °C, max. | 2 A |
| Digital outputs / Cable length / shielded, max. | 1 000 m |
| Digital outputs / Cable length / unshielded, max. | 600 m |
| Interrupts/diagnostics/status information / Alarms | No |
| Interrupts/diagnostics/status information / Diagnostics function | No |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | No |
| Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readable | No |
| Interrupts/diagnostics/status information / Diagnoses / Wire break | No |
| Interrupts/diagnostics/status information / Diagnoses / Short-circuit | No |
| Interrupts/diagnostics/status information / Diagnoses / Missing load voltage | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Rated load voltage PWR (green) | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Fuse OK FSG (green) | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red) | No |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital output (green) | Yes; per channel |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Channel fault indicator F (red) | No |
| Potential separation / Potential separation digital outputs / between the channels | Yes |
| Potential separation / Potential separation digital outputs / between the channels, in groups of | 8 |
| Potential separation / Potential separation digital outputs / between the channels and backplane bus | Yes; Optocoupler |
| Isolation / Isolation tested with | 500 V DC |
| Ambient conditions / Ambient temperature during operation / min. | -25 °C; = Tmin |
| Ambient conditions / Ambient temperature during operation / max. | 70 °C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 °C (T1) or 60 °C @ UL/ULhaz/ATEX/FM use applies |
| Ambient conditions / Ambient temperature during storage/transportation / min. | -40 °C |
| Ambient conditions / Ambient temperature during storage/transportation / max. | 70 °C |
| Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m |
| Ambient conditions / Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
| Ambient conditions / Relative humidity / With condensation, tested in accordance with IEC 60068- | 100 %; RH incl. condensation/frost (no commissioning under condensation |
| Ambient conditions / Relative humidity / 2-38, max. | conditions) |
| Ambient conditions / Resistance / Use in stationary industrial systems / to biologically active substances according to EN | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); |
| Ambient conditions / Resistance / Use in stationary industrial systems / 60721-3-3 | Class 3B3 on request |
| Ambient conditions / Resistance / Use in stationary industrial systems / to chemically active substances according to EN | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity |
| Ambient conditions / Resistance / Use in stationary industrial systems / to mechanically active substances according to EN | Yes; Class 3S4 incl. sand, dust, * |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to biologically active substances according to EN | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / 60721-3-5 | Class 5B3 on request |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to chemically active substances according to EN | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); * |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to mechanically active substances according to EN | Yes; Class 5S3 incl. sand, dust; * |
| Ambient conditions / Resistance / Use on ships/at sea / to biologically active substances according to EN | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on |
| Ambient conditions / Resistance / Use on ships/at sea / 60721-3-6 | request |
| Ambient conditions / Resistance / Use on ships/at sea / to chemically active substances according to EN | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity |
| Ambient conditions / Resistance / Use on ships/at sea / to mechanically active substances according to EN | Yes; Class 6S3 incl. sand, dust; * |
| Ambient conditions / Resistance / Usage in industrial process technology / Against chemically active substances acc. to EN | Yes; Class 3 (excluding trichlorethylene) |
| Ambient conditions / Resistance / Usage in industrial process technology / Environmental conditions for process, measuring | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas |
| Ambient conditions / Resistance / Usage in industrial process technology / and control systems acc. to ANSI/ISA-71.04 | concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Ambient conditions / Resistance / Remark / conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Connection method / required front connector | 40-pin |
| Dimensions / Width | 40 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 260 g |
| Product type designation | SM 322 |
| Number of poles | 40 |
Connections and conditions of use
- Digital outputs / Output voltage / for signal "1", min.: L+ (-0.8 V)
- Digital outputs / Output current / for signal "1" rated value: 0.5 A
- Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.: 5 mA
- Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.: 0.6 A
- Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.: 5 mA
- Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.: 0.6 A
- Digital outputs / Output current / for signal "1" minimum load current: 5 mA
- Digital outputs / Output current / for signal "0" residual current, max.: 0.5 mA
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.