6AG1322-1BH01-2AA0

6AG1322-1BH01-2AA0

Sales, Repair, Purchase

SIEMENS

SIPLUS S7-300 SM 322-20-pole -25...+70 C With conformal coating based on 6ES7322-1BH01-0AA0 . Digital output Isolated 16 DQ, 24 V DC, 0.5 A, total current 4 A/group (8 A/module) More

Code: 6AG1322-1BH01-2AA0

from 322 EUR excl. VAT (389,62 EUR Incl. VAT)
Total in stock: 21 pcs External stock 21 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS S7-300 SM 322-20-pole -25...+70 C With conformal coating based on 6ES7322-1BH01-0AA0 . Digital output Isolated 16 DQ, 24 V DC, 0.5 A, total current 4 A/group (8 A/module) More

Code: 6AG1322-1BH01-2AA0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6AG1322-1BH01-2AA0 NC 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6AG1322-1BH01-2AA0 R 12/24 months In external stock 20 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1322-1BH01-2AA0 O 3-6 weeks 24 months On request Enquire a repair

6AG1322-1BH01-2AA0 – SM 322-20

SIPLUS S7-300 SM 322-20-pole based on 6ES7322-1BH01-0AA0 with conformal coating, -25…+70 °C, digital output isolated 16 DO, 24 V DC, 0.5 A, total current 4 A/group (8 A/module)

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Load voltage L+ / Rated value (DC)
20.4 VSupply voltage / Load voltage L+ / permissible range, lower limit (DC)
28.8 VSupply voltage / Load voltage L+ / permissible range, upper limit (DC)

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6AG1322-1BH01-2AA0
General information / based on6ES7322-1BH01-0AA0
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Supply voltage / Load voltage L+ / permissible range, lower limit (DC)20.4 V
Supply voltage / Load voltage L+ / permissible range, upper limit (DC)28.8 V
Input current / from load voltage L+ (without load), max.80 mA
Input current / from backplane bus 5 V DC, max.80 mA
Power loss / Power loss, typ.4.9 W
Digital outputs / Number of digital outputs16
Digital outputs / Short-circuit protectionYes; Electronic
Digital outputs / Response threshold, typ.1 A
Digital outputs / Limitation of inductive shutdown voltage toL+ (-53 V)
Digital outputs / Controlling a digital inputYes
Digital outputs / Switching capacity of the outputs / on lamp load, max.5 W
Digital outputs / Load resistance range / lower limit48 Ω
Digital outputs / Load resistance range / upper limit4 kΩ
Digital outputs / Output voltage / for signal "1", min.L+ (-0.8 V)
Digital outputs / Output current / for signal "1" rated value0.5 A
Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.0.6 A
Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.5 mA
Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.0.6 A
Digital outputs / Output current / for signal "1" minimum load current5 mA
Digital outputs / Output current / for signal "0" residual current, max.0.5 mA
Digital outputs / Output delay with resistive load / "0" to "1", max.100 µs
Digital outputs / Output delay with resistive load / "1" to "0", max.500 µs
Digital outputs / Parallel switching of two outputs / for upratingNo
Digital outputs / Parallel switching of two outputs / for redundant control of a loadYes
Digital outputs / Switching frequency / with resistive load, max.100 Hz
Digital outputs / Switching frequency / with inductive load, max.0.5 Hz
Digital outputs / Switching frequency / with inductive load (acc. to IEC 60947-5-1, DC13), max.0.5 Hz
Digital outputs / Switching frequency / on lamp load, max.10 Hz
Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 40 °C, max.4 A
Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 60 °C, max.3 A
Digital outputs / Total current of the outputs (per group) / horizontal installation / up to 70 °C, max.3 A
Digital outputs / Total current of the outputs (per group) / vertical installation / up to 40 °C, max.2 A
Digital outputs / Cable length / shielded, max.1 000 m
Digital outputs / Cable length / unshielded, max.600 m
Interrupts/diagnostics/status information / AlarmsNo
Interrupts/diagnostics/status information / Diagnostics functionNo
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmNo
Interrupts/diagnostics/status information / Diagnoses / Wire breakNo
Interrupts/diagnostics/status information / Diagnoses / Short-circuitNo
Interrupts/diagnostics/status information / Diagnoses / Fuse blownNo
Interrupts/diagnostics/status information / Diagnoses / Missing load voltageNo
Interrupts/diagnostics/status information / Diagnostics indication LED / Rated load voltage PWR (green)No
Interrupts/diagnostics/status information / Diagnostics indication LED / Fuse OK FSG (green)No
Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital output (green)Yes
Potential separation / Potential separation digital outputs / between the channelsYes
Potential separation / Potential separation digital outputs / between the channels, in groups of8
Potential separation / Potential separation digital outputs / between the channels and backplane busYes; Optocoupler
Isolation / Isolation tested with500 V DC
Ambient conditions / Ambient temperature during operation / min.-25 °C; = Tmin
Ambient conditions / Ambient temperature during operation / max.70 °C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 °C (T1) or 60 °C @ UL/ULhaz/ATEX/FM use applies
Ambient conditions / Ambient temperature during storage/transportation / min.-40 °C
Ambient conditions / Ambient temperature during storage/transportation / max.70 °C
Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max.5 000 m
Ambient conditions / Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Ambient conditions / Relative humidity / With condensation, tested in accordance with IEC 60068-100 %; RH incl. condensation/frost (no commissioning under condensation
Ambient conditions / Relative humidity / 2-38, max.conditions)
Ambient conditions / Resistance / Use in stationary industrial systems / to biologically active substances according to ENYes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna);
Ambient conditions / Resistance / Use in stationary industrial systems / 60721-3-3Class 3B3 on request
Ambient conditions / Resistance / Use in stationary industrial systems / to chemically active substances according to ENYes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity
Ambient conditions / Resistance / Use in stationary industrial systems / to mechanically active substances according to ENYes; Class 3S4 incl. sand, dust, *
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to biologically active substances according to ENYes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna);
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / 60721-3-5Class 5B3 on request
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to chemically active substances according to ENYes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); *
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to mechanically active substances according to ENYes; Class 5S3 incl. sand, dust; *
Ambient conditions / Resistance / Use on ships/at sea / to biologically active substances according to ENYes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on
Ambient conditions / Resistance / Use on ships/at sea / 60721-3-6request
Ambient conditions / Resistance / Use on ships/at sea / to chemically active substances according to ENYes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity
Ambient conditions / Resistance / Use on ships/at sea / to mechanically active substances according to ENYes; Class 6S3 incl. sand, dust; *
Ambient conditions / Resistance / Usage in industrial process technology / Against chemically active substances acc. to ENYes; Class 3 (excluding trichlorethylene)
Ambient conditions / Resistance / Usage in industrial process technology / Environmental conditions for process, measuringYes; Level GX group A/B (excluding trichlorethylene; harmful gas
Ambient conditions / Resistance / Usage in industrial process technology / and control systems acc. to ANSI/ISA-71.04concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions / Resistance / Remark / conditions acc. to EN 60721, EN 60654-4 andduring operation!
Connection method / required front connector20-pin
Dimensions / Width40 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.190 g
Product type designationSM 322-20
Number of poles20

Connections and conditions of use

  • Digital outputs / Output voltage / for signal "1", min.: L+ (-0.8 V)
  • Digital outputs / Output current / for signal "1" rated value: 0.5 A
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, min.: 5 mA
  • Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.: 0.6 A
  • Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, min.: 5 mA
  • Digital outputs / Output current / for signal "1" permissible range for 40 to 60 °C, max.: 0.6 A
  • Digital outputs / Output current / for signal "1" minimum load current: 5 mA
  • Digital outputs / Output current / for signal "0" residual current, max.: 0.5 mA

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair