SIEMENS

SIPLUS S7-300 SM 321 20-pole based on 6ES7321-7BH01-0AB0 with conformal coating, -25ÔǪ+70 -¦C, digital input isolated 16 DI; 24 V DC, 1x 20-pole, hardware interrupt, diagnostics, suitable for isochronous-mode operation More

Code: 6AG1321-7BH01-2AB0

Total in stock: 2 pcs External stock 2 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS S7-300 SM 321 20-pole based on 6ES7321-7BH01-0AB0 with conformal coating, -25ÔǪ+70 -¦C, digital input isolated 16 DI; 24 V DC, 1x 20-pole, hardware interrupt, diagnostics, suitable for isochronous-mode operation More

Code: 6AG1321-7BH01-2AB0

Part Sales 2

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
New in sealed box (NC) 6AG1321-7BH01-2AB0 NC 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request
Refurbished (R) 6AG1321-7BH01-2AB0 R 12/24 months In external stock 1 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1321-7BH01-2AB0 O 3-6 weeks 24 months On request Enquire a repair

6AG1321-7BH01-2AB0 – SM 321

SIPLUS S7-300 SM 321 20-pole based on 6ES7321-7BH01-0AB0 with conformal coating, -25…+70 °C, digital input isolated 16 DI; 24 V DC, 1x 20- pole, hardware interrupt, diagnostics, suitable for isochronous mode

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
24 VSupply voltage / Load voltage L+ / Rated value (DC)
20.4 VSupply voltage / Load voltage L+ / permissible range, lower limit (DC)
28.8 VSupply voltage / Load voltage L+ / permissible range, upper limit (DC)

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6AG1321-7BH01-2AB0
General information / based on6ES7321-7BH01-0AB0
General information / Product function / Isochronous modeYes
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Supply voltage / Load voltage L+ / permissible range, lower limit (DC)20.4 V
Supply voltage / Load voltage L+ / permissible range, upper limit (DC)28.8 V
Supply voltage / Load voltage L+ / Reverse polarity protectionYes
Input current / from load voltage L+ (without load), max.90 mA
Input current / from backplane bus 5 V DC, max.130 mA
Encoder supply / Number of outputs2
Encoder supply / Type of output voltageL+ (-2.5 V)
Encoder supply / Short-circuit protectionYes; Electronic
Encoder supply / additional (redundant) feedYes
Encoder supply / Output current / Rated value120 mA
Encoder supply / Output current / permissible range, lower limit0 mA
Encoder supply / Output current / permissible range, upper limit150 mA
Power loss / Power loss, typ.4 W
Digital inputs / Number of digital inputs16
Digital inputs / Input characteristic curve in accordance with IEC 61131, type 2Yes
Digital inputs / Number of simultaneously controllable inputs / horizontal installation / up to 60 °C, max.16
Digital inputs / Number of simultaneously controllable inputs / vertical installation / up to 40 °C, max.16
Digital inputs / Input voltage / Type of input voltageDC
Digital inputs / Input voltage / Rated value (DC)24 V
Digital inputs / Input voltage / for signal "0"-30 to +5 V
Digital inputs / Input voltage / for signal "1"13 to 30V
Digital inputs / Input current / for signal "1", typ.7 mA
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / parameterizableYes; 0.1 / 0.5 / 3 / 15 / 20 ms
Digital inputs / Encoder connection / Fixed current limitation for wire-break monitoring, min.10 kΩ
Digital inputs / Encoder connection / Fixed current limitation for wire-break monitoring, max.18 kΩ
Digital inputs / Cable length / shielded, max.1 000 m
Digital inputs / Cable length / unshielded, max.600 m
Encoder / Connectable encoders / 2-wire sensorYes
Encoder / Connectable encoders / permissible quiescent current (2-wire sensor), max.2 mA
Interrupts/diagnostics/status information / AlarmsYes
Interrupts/diagnostics/status information / Diagnostics functionYes; Parameterizable
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmYes; Parameterizable
Interrupts/diagnostics/status information / Alarms / Hardware interruptYes; Parameterizable
Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readableYes
Interrupts/diagnostics/status information / Diagnoses / Wire breakYes; to I< 1 mA
Interrupts/diagnostics/status information / Diagnostics indication LED / Group error SF (red)Yes
Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator digital input (green)Yes
Interrupts/diagnostics/status information / Diagnostics indication LED / Encoder supply Vs (green)Yes
Potential separation / Potential separation digital inputs / between the channelsNo
Potential separation / Potential separation digital inputs / between the channels, in groups of16
Potential separation / Potential separation digital inputs / between the channels and backplane busYes; Optocoupler
Isolation / Isolation tested with500 V DC
Ambient conditions / Ambient temperature during operation / min.-25 °C; = Tmin
Ambient conditions / Ambient temperature during operation / max.70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Ambient conditions / Ambient temperature during storage/transportation / min.-40 °C
Ambient conditions / Ambient temperature during storage/transportation / max.70 °C
Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max.5 000 m
Ambient conditions / Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Ambient conditions / Relative humidity / With condensation, tested in accordance with IEC 60068-100 %; RH incl. condensation/frost (no commissioning under condensation
Ambient conditions / Relative humidity / 2-38, max.conditions)
Ambient conditions / Resistance / Use in stationary industrial systems / to biologically active substances according to ENYes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna);
Ambient conditions / Resistance / Use in stationary industrial systems / 60721-3-3Class 3B3 on request
Ambient conditions / Resistance / Use in stationary industrial systems / to chemically active substances according to ENYes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity
Ambient conditions / Resistance / Use in stationary industrial systems / to mechanically active substances according to ENYes; Class 3S4 incl. sand, dust, *
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to biologically active substances according to ENYes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna);
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / 60721-3-5Class 5B3 on request
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to chemically active substances according to ENYes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); *
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to mechanically active substances according to ENYes; Class 5S3 incl. sand, dust; *
Ambient conditions / Resistance / Use on ships/at sea / to biologically active substances according to ENYes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on
Ambient conditions / Resistance / Use on ships/at sea / 60721-3-6request
Ambient conditions / Resistance / Use on ships/at sea / to chemically active substances according to ENYes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity
Ambient conditions / Resistance / Use on ships/at sea / to mechanically active substances according to ENYes; Class 6S3 incl. sand, dust; *
Ambient conditions / Resistance / Usage in industrial process technology / Against chemically active substances acc. to ENYes; Class 3 (excluding trichlorethylene)
Ambient conditions / Resistance / Usage in industrial process technology / Environmental conditions for process, measuringYes; Level GX group A/B (excluding trichlorethylene; harmful gas
Ambient conditions / Resistance / Usage in industrial process technology / and control systems acc. to ANSI/ISA-71.04concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions / Resistance / Remark / conditions acc. to EN 60721, EN 60654-4 andduring operation!
Connection method / required front connector20-pin
Dimensions / Width40 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.200 g
Product type designationSM 321
Number of poles20

Connections and conditions of use

  • Digital inputs / Input voltage / for signal "0": -30 to +5 V
  • Digital inputs / Input voltage / for signal "1": 13 to 30V
  • Digital inputs / Input current / for signal "1", typ.: 7 mA
  • Digital inputs / Encoder connection / Fixed current limitation for wire-break monitoring, min.: 10 kΩ
  • Digital inputs / Encoder connection / Fixed current limitation for wire-break monitoring, max.: 18 kΩ
  • Connection method / required front connector: 20-pin

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair