6AG1317-6FF00-2AB0
- SIEMENS
- SIMATIC ET 200 / DP
- 6AG1317-6FF00-2AB0
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1317-6FF00-2AB0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1317-6FF00-2AB0 – SIMATIC S7-300 module
Siemens SIMATIC S7-300 SIMATIC S7-300 module.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
CPU application
The CPU executes the user program and handles SIMATIC S7-300 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1317-6FF00-2AB0 |
| Product type designation | SIMATIC S7-300 module |
| Product status / associated programming package | STEP 7 V 5.2 or higher + SP1; S7 Distributed Safety V5.2 + SP1 or higher |
| Supply voltages / Rated value / DC 24 V | Yes |
| Supply voltages / Rated value / permissible range, lower limit (DC) | 20.4 V |
| Supply voltages / Rated value / permissible range, upper limit (DC) | 28.8 V |
| Voltages and currents / external protection for supply cables (recommen- dation) | min. 2 A |
| Current consumption / Inrush current, typ. | 2.5 A |
| Current consumption / I²t | 0.5 A²s |
| Current consumption / Current consumption (in no-load operation), typ. | 60 mA |
| Current consumption / Power loss, typ. | 2.5 W |
| Memory / RAM / expandable | 512 KByte; of which max. 256 kB for retentive DB |
| Memory / RAM | No |
| Memory / Load memory / pluggable (MMC) | Yes |
| Memory / Load memory / pluggable (MMC), max. | 8 MByte |
| Memory / Backup / present | Yes; Guaranteed by MMC (mainte- nance-free) |
| CPU/blocks / DB / Number, max. | 2,047; DB 0 reserved |
| CPU/blocks / DB / Size, max. | 64 KByte |
| FB / Number, max. | 2,048; See Operation List |
| FB / Size, max. | 64 KByte |
| FC / Number, max. | 2,048; See Operation List |
| FC / Size, max. | 64 KByte |
| OB / Size, max. | 64 KByte |
| Nesting depth / per priority class | 8 |
| Nesting depth / additional within an error OB | 4 |
| CPU/processing times / for bit operations, min. | 0.1 µs |
| CPU/processing times / for word operations, min. | 0.1 µs |
| CPU/processing times / for fixed point arithmetic, min. | 0.2 µs |
| CPU/processing times / for floating point arithmetic, min. | 2 µs |
| Times/counters and their remanence / S7 counter / Number | 512 |
| Times/counters and their remanence / S7 counter / of which remanent without battery / adjustable | Yes |
| Times/counters and their remanence / S7 counter / Counting range / lower limit | 0 |
| Times/counters and their remanence / S7 counter / Counting range / upper limit | 999 |
| Times/counters and their remanence / IEC counter / present | Yes |
| Times/counters and their remanence / IEC counter / Type | SFB |
| Times/counters and their remanence / S7 times / Number | 512 |
| Times/counters and their remanence / S7 times / Remanence / adjustable | Yes |
| Times/counters and their remanence / S7 times / Remanence / preset | No retentivity |
| Times/counters and their remanence / S7 times / Time range / lower limit | 10 ms |
| Times/counters and their remanence / S7 times / Time range / upper limit | 9,990 s |
| Times/counters and their remanence / IEC timer / present | Yes |
| Times/counters and their remanence / IEC timer / Type | SFB |
| Data areas and their remanence / Flag / Number, max. | 4,096 Byte |
| Data areas and their remanence / Flag / Remanence available | Yes; MB 0 to MB 4095 |
| Data areas and their remanence / Flag / Number of clock memories | 8; 1 memory byte |
| Data blocks / Number, max. | 2,047; DB 0 reserved |
| Data blocks / Size, max. | 64 KByte |
| Local data / per priority class, max. | 1,024 Byte |
| Address area / I/O address area / Inputs | 8 KByte |
| Address area / I/O address area / Outputs | 8 KByte |
| Address area / I/O address area / of which, distributed / Inputs | 8 KByte |
| Address area / I/O address area / of which, distributed / Outputs | 8 KByte |
| Address area / Process image / Inputs | 1,024 |
| Address area / Process image / Outputs | 1,024 |
| Address area / Digital channels / Inputs | 65,536 |
| Address area / Digital channels / Outputs | 65,536 |
| Address area / Digital channels / Inputs, of which central | 1,024 |
| Address area / Digital channels / Outputs, of which central | 1,024 |
| Address area / Analog channels / Inputs | 1,024 |
| Address area / Analog channels / Outputs | 1,024 |
| Address area / Analog channels / Inputs, of which central | 256 |
| Address area / Analog channels / Outputs, of which central | 256 |
| Hardware config. / Racks, max. | 4 |
| Hardware config. / Modules per rack, max. | 8 |
| Hardware config. / Number of DP masters / integrated | 2 |
| Hardware config. / Number of DP masters / via CP | 2 |
| Hardware config. / Number of operable FMs and CPs (recommended) / FM | 8 |
| Hardware config. / Number of operable FMs and CPs (recommended) / CP, point-to-point | 8 |
| Hardware config. / Number of operable FMs and CPs (recommended) / CP, LAN | 10 |
| Time / Clock / Hardware clock (real-time clock) | Yes |
| Time / Clock / Battery backed and synchronized | Yes |
| Time / Clock / Deviation per day, max. | 10 s |
| Operating hours counter / Number | 4 |
| Operating hours counter / Number/Number range | 0 bis 3 |
| Operating hours counter / Range of values | 0 to 2^31 hours (when using SFC101) |
| Operating hours counter / Granularity | 1 hour |
| Operating hours counter / remanent | Yes; must be restarted at each warm restart |
| Clock synchronization / supports | Yes |
| Clock synchronization / to MPI, Master | Yes |
| Clock synchronization / to MPI, Slave | Yes |
| Clock synchronization / in AS, Master | Yes |
| S7 message functions / Number of login stations for message functions, max. | 32; depending on the configured connections for PG-/ OP- and S7- basic commmunication |
| S7 message functions / Process diagnostic messages | Yes |
| S7 message functions / Simultaneously active Alarm-S blocks, max. | 60 |
| Test commissioning functions / Status/control / Status/control variable | Yes |
| Test commissioning functions / Status/control / Variables | Inputs, outputs, memory bits, DB, times, counters |
| Monitoring functions / Number of variables, max. | 30 |
| Monitoring functions / of which status variable, max. | 30 |
| Monitoring functions / of which control variable, max. | 14 |
| Monitoring functions / Forcing | Yes |
| Monitoring functions / Forcing / Force, variables | Inputs, outputs |
| Monitoring functions / Forcing / Forcing, number of variables, max. | 10 |
| Monitoring functions / Status block | Yes |
| Monitoring functions / Single step | Yes |
| Monitoring functions / Number of breakpoints | 2 |
| Monitoring functions / Diagnostic buffer / present | Yes |
| Monitoring functions / Diagnostic buffer / Number of entries, max. | 100 |
| Monitoring functions / Diagnostic buffer / adjustable | No |
| Communication functions / PG/OP communication | Yes |
| Communication functions / Routing | Yes |
| Communication functions / Global data communication / supported | Yes |
| Communication functions / Global data communication / Size of GD packets, max. | 22 Byte |
| Communication functions / S7 basic communication / supported | Yes |
| Communication functions / S7 communication / supported | Yes |
| Communication functions / S5-compatible communication / supported | Yes; via CP and loadable FC |
| Communication functions / Number of connections / overall | 32 |
| Communication functions / Number of connections / usable for PG communication | 31 |
| Communication functions / Number of connections / usable for OP communication | 31 |
| Communication functions / Number of connections / usable for S7 basic communication | 31 |
| 1st interface / Type of interface | Integral RS 485 interface |
| 1st interface / Physics | RS 485 |
| 1st interface / isolated | No |
| 1st interface / Power supply to interface (15 to 30 V DC), max. | 200 mA |
| 1st interface / Functionality / MPI | Yes |
| 1st interface / Functionality / DP master | Yes |
| 1st interface / Functionality / DP slave | No |
| 1st interface / Functionality / Point-to-point coupling | No |
| 1st interface / MPI / Number of connections | 32 |
| 1st interface / MPI / Services / PG/OP communication | Yes |
| 1st interface / MPI / Services / Routing | Yes |
| 1st interface / MPI / Services / Global data communication | Yes |
| 1st interface / MPI / Services / S7 basic communication | Yes |
| 1st interface / MPI / Services / S7 communication | Yes |
| 1st interface / MPI / Services / S7 communication, as client | Yes; via CP and loadable FB |
| 1st interface / MPI / Services / S7 communication, as server | Yes |
| 1st interface / MPI / Transmission speeds, max. | 12 Mbit/s |
| DP master / Number of connections, max. | 32 |
| DP master / Services / PG/OP communication | Yes |
| DP master / Services / Routing | Yes |
| DP master / Services / Global data communication | No |
| DP master / Services / S7 basic communication | No |
| DP master / Services / S7 communication | No |
| DP master / Services / equidistance support | Yes |
| DP master / Services / SYNC/FREEZE | Yes |
| DP master / Services / DPV1 | Yes |
| DP master / Transmission speeds, max. | 12 Mbit/s |
| DP master / Number of DP slaves, max. | 125 |
| DP master / Address area / Inputs, max. | 244 KByte |
| DP master / Address area / Outputs, max. | 244 KByte |
| 2nd interface / Type of interface | Integral RS 485 interface |
| 2nd interface / Physics | RS 485 |
| 2nd interface / isolated | Yes |
| 2nd interface / Power supply to interface (15 to 30 V DC), max. | 200 mA |
| 2nd interface / Functionality / MPI | No |
| 2nd interface / Functionality / DP master | Yes |
| 2nd interface / Functionality / DP slave | Yes |
| 2nd interface / Functionality / Point-to-point coupling | No |
| 2nd interface / DP master / Number of connections, max. | 32 |
| 2nd interface / DP master / Services / PG/OP communication | Yes |
| 2nd interface / DP master / Services / Routing | Yes |
| 2nd interface / DP master / Services / Global data communication | No |
| 2nd interface / DP master / Services / S7 basic communication | No |
| 2nd interface / DP master / Services / S7 communication | No |
| 2nd interface / DP master / Services / equidistance support | Yes |
| 2nd interface / DP master / Services / SYNC/FREEZE | Yes |
| 2nd interface / DP master / Services / DPV1 | Yes |
| 2nd interface / DP master / Transmission speeds, max. | 12 Mbit/s |
| 2nd interface / DP master / Number of DP slaves, max. | 125 |
| 2nd interface / DP master / Address area / Inputs, max. | 244 KByte |
| 2nd interface / DP master / Address area / Outputs, max. | 244 KByte |
| DP slave / Number of connections | 32 |
| DP slave / Services / PG/OP communication | Yes |
| DP slave / Services / Routing | Yes; when interface active |
| DP slave / Services / Global data communication | No |
| DP slave / Services / S7 basic communication | No |
| DP slave / Services / S7 communication, as client | No |
| DP slave / Services / S7 communication, as server | No |
| DP slave / Services / direct data exchange (cross traffic) | Yes |
| DP slave / Services / DPV1 | No |
| DP slave / GSD file | http://www.ad. siemens.de/csi_e/ gsd |
| DP slave / Transmission speeds, max. | 12 Mbit/s |
| DP slave / Transfer memory / Inputs | 244 Byte |
| DP slave / Transfer memory / Outputs | 244 Byte |
| DP slave / Address area, max. | 32 |
| DP slave / Useful data per address area, max. | 32 Byte |
| CPU/programming / Programming language / STEP 7 | Yes; STEP 7 as of V 5.2 + SP1; S7 Distributed Safety as of V5.2 SP1 |
| CPU/programming / Programming language / LAD | Yes |
| CPU/programming / Programming language / FUP | Yes |
| CPU/programming / Programming language / AWL | Yes |
| CPU/programming / Programming language / SCL | Yes |
| CPU/programming / Operational stocks | See Operation List |
| CPU/programming / Nesting levels | 8 |
| CPU/programming / User program protection/password protection | Yes |
| CPU/programming / System functions (SFC) | See Operation List |
| CPU/programming / System function blocks (SFB) | See Operation List |
| Dimensions and weight / Width | 80 mm |
| Dimensions and weight / Height | 125 mm |
| Dimensions and weight / Depth | 130 mm |
| Weights / Weight, approx. | 560 g |
Communication and configuration
- Product status / associated programming package: STEP 7 V 5.2 or higher + SP1; S7 Distributed Safety V5.2 + SP1 or higher
- Memory / Load memory / pluggable (MMC): Yes
- Memory / Load memory / pluggable (MMC), max.: 8 MByte
- Communication functions / PG/OP communication: Yes
- Communication functions / Routing: Yes
- Communication functions / Global data communication / supported: Yes
- Communication functions / Global data communication / Size of GD packets, max.: 22 Byte
- Communication functions / S7 basic communication / supported: Yes
Scope of supply
We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What must be checked for firmware and a STEP 7 or TIA Portal project?
Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.
Does the memory card need to be checked?
Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.