6AG1314-6CF02-2AB0

6AG1314-6CF02-2AB0

Sales, Repair, Purchase

SIEMENS

SIPLUS S7-300 CPU314C-2DP -25 ... +60 dgr C based on 6ES7314-6CF02-0AB0 More

Code: 6AG1314-6CF02-2AB0

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS S7-300 CPU314C-2DP -25 ... +60 dgr C based on 6ES7314-6CF02-0AB0 More

Code: 6AG1314-6CF02-2AB0

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1314-6CF02-2AB0 O 3-6 weeks 24 months On request Enquire a repair

6AG1314-6CF02-2AB0 – SIMATIC S7-300 module

Siemens SIMATIC S7-300 SIMATIC S7-300 module.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
64 KByte; for program and data, less the display dataMemory / RAM / integrated
RS 4851st interface / Physics
RS 4852nd interface / Physics

CPU application

The CPU executes the user program and handles SIMATIC S7-300 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.

Technical specifications

ManufacturerSiemens
Order number6AG1314-6CF02-2AB0
Product type designationSIMATIC S7-300 module
Product status / associated programming packageSTEP 7 V 5.2 or higher + SP 1 with HW update
Supply voltages / Rated value / DC 24 VYes
Supply voltages / Rated value / permissible range, lower limit (DC)20.4 V
Supply voltages / Rated value / permissible range, upper limit (DC)28.8 V
Current consumption / Inrush current, typ.11 A
Current consumption / I²t0.7 A²s
Current consumption / Current consumption (in no-load operation), typ.150 mA
Current consumption / Current consumption (rated value)1,000 mA
Current consumption / from supply voltage L+, max.1,000 mA
Current consumption / Power loss, typ.14 W
Memory / RAM / integrated64 KByte; for program and data, less the display data
Memory / RAM / expandableNo
Memory / Load memory / pluggable (MMC)Yes
Memory / Load memory / pluggable (MMC), max.8 MByte
Memory / Backup / presentYes; Guaranteed by MMC (maintenance-free)
Memory / Backup / without batteryYes; Program and data
CPU/blocks / DB / Number, max.511; Number band: 1 to 511
CPU/blocks / DB / Size, max.16 KByte
CPU/blocks / FB / Number, max.512; Number band: 0 to 2047
CPU/blocks / FB / Size, max.16 KByte
CPU/blocks / FC / Number, max.512; Number band: 0 to 2047
CPU/blocks / FC / Size, max.16 KByte
CPU/blocks / OB / Size, max.16 KByte
CPU/blocks / Nesting depth / per priority class8
CPU/blocks / Nesting depth / additional within an error OB4
CPU/processing times / for bit operations, min.0.1 µs
CPU/processing times / for word operations, min.0.2 µs
CPU/processing times / for fixed point arithmetic, min.2 µs
CPU/processing times / for floating point arithmetic, min.3 µs
Times/counters and their remanence / S7 counter / Number256
S7 counter (continued) / of which remanent without battery / adjustableYes
S7 counter (continued) / of which remanent without battery / lower limit0
S7 counter (continued) / of which remanent without battery / upper limit256
S7 counter (continued) / Counting range / lower limit0
S7 counter (continued) / Counting range / upper limit999
IEC counter / presentYes
IEC counter / TypeSFB
S7 times / Number256
S7 times / Remanence / adjustableYes
S7 times / Remanence / lower limit0
S7 times / Remanence / upper limit256
S7 times / Remanence / presetno retentivity
S7 times / Time range / lower limit10 ms
S7 times / Time range / upper limit9,990 s
IEC timer / presentYes
IEC timer / TypeSFB
Data areas and their remanence / Flag / Number, max.256 Byte
Data areas and their remanence / Flag / Remanence availableYes; MB 0 to MB 255
Data areas and their remanence / Flag / Number of clock memories8
Data areas and their remanence / Data blocks / Number, max.511
Data areas and their remanence / Data blocks / Size, max.16 KByte
Data areas and their remanence / Local data / per priority class, max.510 Byte
Address area / I/O address area / Inputs1 KByte
Address area / I/O address area / Outputs1 KByte
Address area / Process image / Inputs128 Byte
Address area / Process image / Outputs128 Byte
Address area / Digital channels / Inputs992
Address area / Digital channels / Outputs992
Address area / Digital channels / Inputs, of which central992
Address area / Digital channels / Outputs, of which central992
Address area / Analog channels / Inputs512
Address area / Analog channels / Outputs124
Address area / Analog channels / Inputs, of which central248
Address area / Analog channels / Outputs, of which central248
Hardware config. / Central devices, max.1
Hardware config. / Expansion devices, max.3
Hardware config. / Racks, max.4
Hardware config. / Modules per rack, max.8; in rack 3 max. 7
Hardware config. / Number of DP masters / integrated1
Hardware config. / Number of DP masters / via CP4
Hardware config. / Number of operable FMs and CPs (recommended) / FM8
Hardware config. / Number of operable FMs and CPs (recommended) / CP, point-to-point8
Hardware config. / Number of operable FMs and CPs (recommended) / CP, LAN10
Time / Clock / Hardware clock (real-time clock)Yes
Time / Clock / Battery backed and synchronizedYes
Time / Clock / Deviation per day, max.10 s
Time / Operating hours counter / Number1
Time / Operating hours counter / Number/Number range0
Time / Operating hours counter / Granularity1 hour
Time / Operating hours counter / remanentYes
Time / Clock synchronization / supportsYes
Time / Clock synchronization / to MPI, MasterYes
Time / Clock synchronization / to MPI, SlaveYes
Time / Clock synchronization / in AS, MasterYes
S7 message functions / Number of login stations for message functions, max.12
S7 message functions / Process diagnostic messagesYes
S7 message functions / simultaneously active Alarm-S blocks, max.40
Test commissioning functions / Status/control / Status/control variableYes
Test commissioning functions / Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Monitoring functions / Number of variables, max.30
Monitoring functions / of which status variable, max.30
Monitoring functions / of which control variable, max.14
Monitoring functions / ForcingYes
Monitoring functions / Forcing / Force, variablesInputs, outputs
Monitoring functions / Forcing / Forcing, number of variables, max.10
Monitoring functions / Status blockYes
Monitoring functions / Single stepYes
Monitoring functions / Number of breakpoints2
Monitoring functions / Diagnostic buffer / presentYes
Monitoring functions / Diagnostic buffer / Number of entries, max.100
Communication functions / PG/OP communicationYes
Communication functions / RoutingYes
Communication functions / Global data communication / supportedYes
Communication functions / Global data communication / Size of GD packets, max.22 Byte
Communication functions / S7 basic communication / supportedYes
Communication functions / S7 communication / supportedYes
Communication functions / S5-compatible communication / supportedYes; via CP and loadable FC
Communication functions / Number of connections / overall12
Communication functions / Number of connections / usable for PG communication11
Communication functions / Number of connections / usable for OP communication11
Communication functions / Number of connections / usable for S7 basic commu- nication8
Communication functions / Number of connections / usable for routing4
Connection point / required front connectors2 x 40-pin
MPI / Cable length, max.50 m; without repeater
1st interface / Type of interfaceintegrated RS 422/ 485 interface
1st interface / PhysicsRS 485
1st interface / isolatedNo
1st interface / Power supply to interface (15 to 30 V DC), max.200 mA
1st interface / Functionality / MPIYes
1st interface / Functionality / DP masterNo
1st interface / Functionality / DP slaveNo
1st interface / Functionality / Point-to-point couplingNo
MPI / Number of connections12
MPI / Services / PG/OP communicationYes
MPI / Services / RoutingYes
MPI / Services / Global data communicationYes
MPI / Services / S7 basic communicationYes
MPI / Services / S7 communicationYes
MPI / Services / S7 communication, as clientNo
MPI / Services / S7 communication, as serverYes
MPI / Transmission speeds, max.187.5 kBit/s
2nd interface / Type of interfaceintegrated RS 422/ 485 interface
2nd interface / PhysicsRS 485
2nd interface / isolatedYes
2nd interface / Power supply to interface (15 to 30 V DC), max.200 mA
2nd interface / Functionality / MPINo
2nd interface / Functionality / DP masterYes
2nd interface / Functionality / DP slaveYes
2nd interface / Functionality / Point-to-point couplingNo
2nd interface / DP master / Number of connections, max.8; for PG/OP communication
2nd interface / DP master / Number of connections (of which reserved), max.1 for PG, 1 for OP
2nd interface / DP master / Services / PG/OP communicationYes
2nd interface / DP master / Services / RoutingYes
2nd interface / DP master / Services / Global data communicationNo
2nd interface / DP master / Services / S7 basic communicationYes
2nd interface / DP master / Services / S7 communicationYes
2nd interface / DP master / Services / S7 communication, as clientNo
2nd interface / DP master / Services / S7 communication, as serverYes
2nd interface / DP master / Services / equidistance supportYes
2nd interface / DP master / Services / SYNC/FREEZEYes
2nd interface / DP master / Services / Activation/deactivation of DP slavesYes
2nd interface / DP master / Services / direct data exchange (cross traffic)Yes
2nd interface / DP master / Services / DPV1Yes
2nd interface / DP master / Transmission speeds, max.12 Mbit/s
2nd interface / DP master / Number of DP slaves, max.32
2nd interface / DP master / Address area / Inputs, max.1 KByte
2nd interface / DP master / Address area / Outputs, max.1 KByte
2nd interface / DP master / Useful data per DP slave / Inputs, max.244 Byte
2nd interface / DP master / Useful data per DP slave / Outputs, max.244 Byte
DP slave / Number of connections12
DP slave / Services / PG/OP communicationYes
DP slave / Services / RoutingYes
DP slave / Services / Global data communicationNo
DP slave / Services / S7 basic communicationYes
DP slave / Services / direct data exchange (cross traffic)Yes
DP slave / Services / DPV1No
DP slave / GSD fileYou can obtain the current GSD file from http://www.ad.siemens.de/ support in the Product Support area
DP slave / Transmission speeds, max.12 kBit/s
DP slave / automatic baud rate searchYes
DP slave / Transfer memory / Inputs244 Byte
DP slave / Transfer memory / Outputs244 Byte
DP slave / Address area, max.32
DP slave / Useful data per address area, max.32 Byte
CPU/programming / Programming language / STEP 7Yes; V5.2 SP1 with HW update
CPU/programming / Programming language / LADYes
CPU/programming / Programming language / FUPYes
CPU/programming / Programming language / AWLYes
CPU/programming / Programming language / SCLYes
CPU/programming / Programming language / CFCYes
CPU/programming / Programming language / GRAPHYes
CPU/programming / Programming language / HiGraphYes
CPU/programming / Operational stockssee Instruction List
CPU/programming / Nesting levels8
CPU/programming / User program protection/password protectionYes
CPU/programming / System functions (SFC)see Instruction List
CPU/programming / System function blocks (SFB)see Instruction List
Digital inputs / Number of digital inputs24
Digital inputs / Cable length / Cable length, shielded, max.1,000 m; 100 m for technological functions
Digital inputs / Cable length / Cable length unshielded, max.600 m
Digital inputs / Input voltage / Rated value, DC24 V
Digital inputs / Input voltage / for signal "0"3 to 5 V
Digital inputs / Input voltage / for signal "1"15 to 30 V
Input current / for signal "1", typ.8 mA
Input delay (for rated value of input voltage) / for standard inputs / programmableYes; 0.1 / 0.3 / 3 / 15 ms
Input delay (for rated value of input voltage) / for counter/technological functions / at "0" to "1", max.8 µs
Digital outputs / Number of digital outputs16
Digital outputs / Cable length, shielded, max.1,000 m
Digital outputs / Cable length unshielded, max.600 m
Digital outputs / Short-circuit protection of the outputYes; clocked electroni- cally
Digital outputs / Limitation of inductive shutdown voltage toL+ (-48 V)
Digital outputs / Output voltage / for signal "1", min.L+ (-0,8 V)
Digital outputs / Output current / for signal "1" permissible range for 0 to 40 °C, max.500 mA
Digital outputs / Output current / for signal "1" permissible range for 0 to 60 °C, max.500 mA
Digital outputs / Output current / for signal "1" minimum load current5 mA
Digital outputs / Output current / for signal "0" residual current, max.0,5 mA
Digital outputs / Switching frequency / with resistive load, max.100 Hz
Digital outputs / Switching frequency / with inductive load, max.0.5 Hz
Digital outputs / Aggregate current of the outputs (per group) / up to 40 °C, max.8 A
Digital outputs / Aggregate current of the outputs (per group) / up to 60 °C, max.4 A
Analog inputs / Number of analog inputs for voltage/current measurement4
Analog inputs / Number of analog inputs for resistance/temperature measurement1
Analog inputs / Technical unit for temperature measurement, adjustableYes
Analog inputs / Input ranges (rated values), voltages / 0 to +10 VYes
Analog inputs / Input ranges (rated values), voltages / 10 V to +10 VYes
Analog inputs / Input ranges (rated values), currents / 0 to 20 mAYes
Analog inputs / Input ranges (rated values), currents / 20 to +20 mAYes
Analog inputs / Input ranges (rated values), currents / 4 to 20 mAYes
Input ranges (rated values), resistors / 0 to 600 OhmYes
Input ranges (rated values), resistance thermometers / Pt 100Yes
Analog outputs / Number of analog outputs2
Analog outputs / Output ranges, voltage / 0 to 10 VYes
Analog outputs / Output ranges, voltage / 10 to +10 VYes
Analog outputs / Output ranges, current / 0 to 20 mAYes
Analog outputs / Output ranges, current / 20 to +20 mAYes
Analog outputs / Output ranges, current / 4 to 20 mAYes
Analog value creation / Integrations and conversion time/resolutionper channel / Resolution with overload area (bit including sign), max.12 Bit
Analog value creation / Integrations and conversion time/resolutionper channel / Integration time, parameterizableYes; 2.5 / 16.6 / 20 ms
Analog value creation / Integrations and conversion time/resolutionper channel / Conversion time (per channel)1 ms
Encoder / Connectable encoders / 2-wire BEROSYes
Encoder / Connectable encoders / permissible quiescent current (2-wire BEROS), max.1.5 mA
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to output area+/- 0,7 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to output area+/- 0,7 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to input area+/- 0,7 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input area+/- 0,7 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Impedance, relative to input area+/- 3 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Resistance-type thermometer, relative to input area+/- 3 %
Integrated Functions / Number of counters4
Integrated Functions / Counter frequency (counter) max.60 kHz
Integrated Functions / Frequency measurementYes
Integrated Functions / Controlled positioningYes
Integrated Functions / PID controllerYes
Number of pulse outputs4
Limit frequency (pulse)2.5 kHz
Isolation / Isolation, analog outputs / Galvanic isolation, analog outputsYes
Isolation / Isolation, analog outputs / between the channels and the backplane busYes
Isolation / Isolation, analog inputsYes
Isolation / Isolation, analog inputs / between the channels and the backplane busYes
Isolation / Isolation, digital outputs / Galvanic isolation, digital outputsYes
Isolation / Isolation, digital outputs / between the channels, in groups of8
Isolation / Isolation, digital outputs / between the channels and the backplane busYes
Isolation / Galvanic isolation, digital inputs / galvanic isolation, digital inputsYes
Isolation / Galvanic isolation, digital inputs / between the channels, in groups of16
Isolation / Galvanic isolation, digital inputs / between the channels and the backplane busYes
Dimensions and weight / Width120 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth130 mm
Weights / Weight, approx.676 g

Communication and configuration

  • Product status / associated programming package: STEP 7 V 5.2 or higher + SP 1 with HW update
  • Memory / Load memory / pluggable (MMC): Yes
  • Memory / Load memory / pluggable (MMC), max.: 8 MByte
  • Communication functions / PG/OP communication: Yes
  • Communication functions / Routing: Yes
  • Communication functions / Global data communication / supported: Yes
  • Communication functions / Global data communication / Size of GD packets, max.: 22 Byte
  • Communication functions / S7 basic communication / supported: Yes

Scope of supply

We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What must be checked for firmware and a STEP 7 or TIA Portal project?

Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.

Does the memory card need to be checked?

Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair