6AG1314-1AF11-2AB0 – SIMATIC S7-300 module

Siemens SIMATIC S7-300 SIMATIC S7-300 module.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
64 KByteMemory / RAM / integrated
RS 4851st interface / Physics
SIMATIC S7-300 moduleProduct type designation

CPU application

The CPU executes the user program and handles SIMATIC S7-300 communication. Before replacement, check the complete order number, actual firmware version, memory card and interface configuration in the original project.

Technical specifications

ManufacturerSiemens
Order number6AG1314-1AF11-2AB0
Product type designationSIMATIC S7-300 module
Product status / associated programming packageSTEP 7 V 5.2 or higher + SP 1 with HW update
Supply voltages / Rated value / DC 24 VYes
Supply voltages / Rated value / permissible range, lower limit (DC)20.4 V
Rated value (continued) / permissible range, upper limit (DC)28.8 V
Voltages and currents / external protection for supply cables (recommendation)min. 2 A
Current consumption / Inrush current, typ.2,5 A
Current consumption / I²t0,5 A²s
Current consumption / Current consumption (in no-load operation), typ.60 mA
Current consumption / Current consumption (rated value)0,6 A
Current consumption / from supply voltage L+, max.600 mA
Current consumption / Power loss, typ.2.5 W
Memory / RAM / integrated64 KByte
Memory / RAM / expandableNo
Memory / Load memory / pluggable (MMC)Yes
Memory / Load memory / pluggable (MMC), max.8 MByte
Memory / Backup / presentYes; Guaranteed by MMC (maintenance-free)
CPU/blocks / DB / Number, max.511; Number band: 1 to 511
CPU/blocks / DB / Size, max.16 KByte
CPU/blocks / FB / Number, max.512; Number band: 0 to 2047
CPU/blocks / FB / Size, max.16 KByte
CPU/blocks / FC / Number, max.512; Number band: 0 to 2047
CPU/blocks / FC / Size, max.16 KByte
CPU/blocks / OB / Size, max.16 KByte
CPU/blocks / Nesting depth / per priority class8
CPU/blocks / Nesting depth / additional within an error OB4
CPU/processing times / for bit operations, min.0.1 µs
CPU/processing times / for word operations, min.0.2 µs
CPU/processing times / for fixed point arithmetic, min2 µs
CPU/processing times / for floating point arithmetic, min.3 µs
Times/counters and their remanence / S7 counter / Number256
Times/counters and their remanence / S7 counter / of which remanent without battery / adjustableYes
Times/counters and their remanence / S7 counter / Remanence / adjustableYes
Times/counters and their remanence / S7 counter / Counting range / adjustableYes
Times/counters and their remanence / S7 counter / Counting range / lower limit0
Times/counters and their remanence / S7 counter / Counting range / upper limit999
Times/counters and their remanence / IEC counter / presentYes
Times/counters and their remanence / IEC counter / TypeSFB
Times/counters and their remanence / S7 times / Number256
Times/counters and their remanence / S7 times / Remanence / adjustableYes
Times/counters and their remanence / S7 times / Remanence / presetNo retentivity
Times/counters and their remanence / S7 times / Time range / lower limit10 ms
Times/counters and their remanence / S7 times / Time range / upper limit9,990 s
Times/counters and their remanence / IEC timer / presentYes
Times/counters and their remanence / IEC timer / TypeSFB
Data areas and their remanence / Flag / Number, max.256 Byte
Data areas and their remanence / Flag / Remanence availableYes; MB 0 to MB 255
Data areas and their remanence / Flag / Number of clock memories8; 1 memory byte
Data areas and their remanence / Data blocks / Number, max.511; from DB1 to DB511
Data areas and their remanence / Data blocks / Size, max.16 KByte
Data areas and their remanence / Local data / per priority class, max.510 Byte
Address area / I/O address area / Inputs1 KByte
Address area / I/O address area / Outputs1 KByte
Process image / Inputs128 Byte
Process image / Outputs128 Byte
Digital channels / Inputs1,024
Digital channels / Outputs1,024
Digital channels / Inputs, of which central1,024
Digital channels / Outputs, of which central1,024
Analog channels / Inputs256
Analog channels / Outputs256
Analog channels / Inputs, of which central256
Analog channels / Outputs, of which central256
Hardware config. / Racks, max.4
Hardware config. / Modules per rack, max.8
Hardware config. / Number of DP masters / integrated0
Hardware config. / Number of DP masters / via CP4
Hardware config. / Number of operable FMs and CPs (recommended) / FM8
Hardware config. / Number of operable FMs and CPs (recommended) / CP, point-to-point8
Hardware config. / Number of operable FMs and CPs (recommended) / CP, LAN10
Time / Clock / Hardware clock (real-time clock)Yes
Time / Clock / Battery backed and synchronizedYes
Time / Clock / Deviation per day, max.10 s
Time / Operating hours counter / Number1
Time / Operating hours counter / Number/Number range0
Time / Operating hours counter / Range of values0 to 2^31 hours (when using SFC101)
Time / Operating hours counter / Granularity1 hour
Time / Operating hours counter / remanentYes; must be restarted at each warm restart
Time / Clock synchronization / supportsYes
Time / Clock synchronization / to MPI, MasterYes
Time / Clock synchronization / to MPI, SlaveYes
Time / Clock synchronization / in AS, MasterYes
S7 message functions / Number of login stations for message functions, max.12; depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
Simultaneously active Alarm-S blocks, max.40
Test commissioning functions / Status/control / Status/control variableYes
Test commissioning functions / Status/control / VariablesInputs, outputs, memory bits, DB, times, counters
Monitoring functions / Number of variables, max.30
Monitoring functions / of which status variable, max.30
Monitoring functions / of which control variable, max.14
Monitoring functions / ForcingYes
Monitoring functions / Forcing / Force, variablesInputs, outputs
Monitoring functions / Forcing / Forcing, number of variables, max.10
Monitoring functions / Status blockYes
Monitoring functions / Single stepYes
Monitoring functions / Number of breakpoints2
Monitoring functions / Diagnostic buffer / presentYes
Monitoring functions / Diagnostic buffer / Number of entries, max.100
Monitoring functions / Diagnostic buffer / adjustableNo
Communication functions / PG/OP communicationYes
Communication functions / RoutingNo
Communication functions / Global data communication / supportedYes
Communication functions / Global data communication / Size of GD packets, max.22 Byte
Communication functions / S7 basic communication / supportedYes
Communication functions / S7 communication / supportedYes
Communication functions / S5-compatible communication / supportedYes; via CP and loadable FC
Communication functions / Number of connections / overall12
Communication functions / Number of connections / usable for PG communication11
Communication functions / Number of connections / usable for OP communication11
Communication functions / Number of connections / usable for S7 basic communication8
1st interface / Type of interfaceIntegral RS 485 interface
1st interface / PhysicsRS 485
1st interface / isolatedNo
1st interface / Power supply to interface (15 to 30 V DC), max.200 mA
1st interface / Functionality / MPIYes
1st interface / Functionality / DP masterNo
1st interface / Functionality / DP slaveNo
1st interface / Functionality / Point-to-point couplingNo
1st interface / MPI / Number of connections12
1st interface / MPI / Services / PG/OP communicationYes
1st interface / MPI / Services / RoutingNo
1st interface / MPI / Services / Global data communicationYes
1st interface / MPI / Services / S7 basic communicationYes
1st interface / MPI / Services / S7 communicationYes
1st interface / MPI / Services / S7 communication, as clientNo
1st interface / MPI / Services / S7 communication, as serverYes
1st interface / MPI / Transmission speeds, max.187.5 kBit/s
CPU/programming / Programming language / STEP 7Yes; V 5.2 SP 1 or higher with HW update
CPU/programming / Programming language / LADYes
CPU/programming / Programming language / FUPYes
CPU/programming / Programming language / AWLYes
CPU/programming / Programming language / SCLYes
CPU/programming / Programming language / CFCYes
CPU/programming / Programming language / GRAPHYes
CPU/programming / Programming language / HiGraphYes
Operational stocksSee Operation List
Nesting levels8
User program protection/password protectionYes
System functions (SFC)See Operation List
System function blocks (SFB)See Operation List
Dimensions and weight / Width40 mm
Dimensions and weight / Height125 mm
Dimensions and weight / Depth130 mm
Weights / Weight, approx.280 g

Communication and configuration

  • Product status / associated programming package: STEP 7 V 5.2 or higher + SP 1 with HW update
  • Memory / Load memory / pluggable (MMC): Yes
  • Memory / Load memory / pluggable (MMC), max.: 8 MByte
  • Communication functions / PG/OP communication: Yes
  • Communication functions / Routing: No
  • Communication functions / Global data communication / supported: Yes
  • Communication functions / Global data communication / Size of GD packets, max.: 22 Byte
  • Communication functions / S7 basic communication / supported: Yes

Scope of supply

We will confirm the specific scope of supply, packaging and any accessories in the quotation. For replacement CPUs, we will also check the memory card and other items needed for commissioning.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What must be checked for firmware and a STEP 7 or TIA Portal project?

Check the replacement unit's actual firmware and the availability of this exact CPU in the hardware catalog of your engineering version. TIA Portal support cannot be confirmed from the product family name alone. A change of CPU type normally requires modification or at least a thorough check of the project.

Does the memory card need to be checked?

Yes. Check the memory card type and capacity, program and data contents and the original CPU's backup arrangement. We will specify the required card and accessories in the quotation.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair