6AG1305-1BA80-2AA0
- SIEMENS
- SIMATIC ET 200 / DP
- 6AG1305-1BA80-2AA0
6AG1305-1BA80-2AA0
SIPLUS S7-300 PS 305 based on 6ES7305-1BA80-0AA0 with conformal coating, -25ÔǪ+70 -¦C, stabilized power supply input: 24-110 V DC output: 24 V DC/2 A More
Code: 6AG1305-1BA80-2AA0
SIPLUS S7-300 PS 305 based on 6ES7305-1BA80-0AA0 with conformal coating, -25ÔǪ+70 -¦C, stabilized power supply input: 24-110 V DC output: 24 V DC/2 A More
Code: 6AG1305-1BA80-2AA0
Part Sales 1
| Condition | Code | Warranty | Availability |
Delivery Express? | Price excl. VAT | |
|---|---|---|---|---|---|---|
| Refurbished (R) | 6AG1305-1BA80-2AA0 R | 12/24 months | In external stock 4 pcs |
Within 2-4 days / Express
|
On request
|
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1305-1BA80-2AA0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1305-1BA80-2AA0 – PS 305
SIPLUS S7-300 PS 305 based on 6ES7305-1BA80-0AA0 with conformal coating, -25…+70 °C, stabilized power supply input: 24-110 V DC output: 24 V DC/2 A
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Application and selection
Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1305-1BA80-2AA0 |
| General information / based on | 6ES7305-1BA80-0AA0 |
| Supply voltage / Rated value (DC) / 24 V DC | Yes |
| Supply voltage / Rated value (DC) / 48 V DC | Yes |
| Supply voltage / Rated value (DC) / 72 V DC | Yes |
| Supply voltage / Rated value (DC) / 96 V DC | Yes |
| Supply voltage / Rated value (DC) / 120 V DC | Yes; Rated value 110 V DC |
| Supply voltage / Mains buffering / Mains/voltage failure stored energy time | 10 ms; Corresponds to S2 and C1 of EN 50155 |
| Supply voltage / Mains buffering / Repeat rate, min. | 1 s |
| Input current / Rated value at 24 V DC | 2.7 A |
| Input current / Rated value at 48 V DC | 1.3 A |
| Input current / Rated value at 72 V DC | 0.9 A |
| Input current / Rated value at 96 V DC | 0.65 A |
| Input current / Rated value at 110 V DC | 0.6 A |
| Input current / Inrush current, max. | 20 A |
| Input current / I²t | 5 A²·s |
| Input current / Leakage current, typ. | 0.7 mA |
| Input current / Leakage current, max. | 3.5 mA |
| Input current / Overcurrent overload capability | 270 ms on short circuit during startup and operation |
| Output voltage / Rated value (DC) | 24 V |
| Output voltage / permissible range, lower limit (DC) | 23.27 V |
| Output voltage / permissible range, upper limit (DC) | 24.72 V |
| Output voltage / Power up time, max. | 3 s |
| Output voltage / Residual ripple, typ. | 30 mV; Peak - peak |
| Output voltage / Residual ripple, max. | 150 mV; Peak - peak |
| Output current / Current output (rated value) | 2 A; 2 for connection in parallel |
| Output current / Short-circuit protection | Yes; Electronic |
| Power / Active power input, typ. | 64 W |
| Power / Efficiency | 75 % |
| Power loss / Power loss, typ. | 16 W |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator output 24 V OK (green) | Yes |
| Potential separation / primary/secondary | Yes; SELV output voltage Ua according to EN 60950-1 and EN 50178 |
| Isolation / Isolation tested with | Rated insulation voltage (24 V against input): 150 V AC tested with: 2800 V DC |
| EMC / EMC interference immunity | EN 61000-6-2 |
| EMC / EMC interference emission | EN 55011 Class A |
| Degree and class of protection / Equipment protection class | I |
| Ambient conditions / Ambient temperature during operation / min. | -25 °C; = Tmin |
| Ambient conditions / Ambient temperature during operation / max. | 70 °C; = Tmax; for use on railway vehicles according to EN 50155, the rated temperature range -25 ... +55 °C (T1) or 60 °C @ UL/UL hazardous use applies |
| Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max. | 2 000 m |
| Ambient conditions / Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); above 2 000 m max. 75 V DC |
| Ambient conditions / Relative humidity / With condensation, tested in accordance with IEC 60068- | 100 %; RH incl. condensation/frost (no commissioning under condensation |
| Ambient conditions / Relative humidity / 2-38, max. | conditions) |
| Ambient conditions / Resistance / Use in stationary industrial systems / to biologically active substances according to EN | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); |
| Ambient conditions / Resistance / Use in stationary industrial systems / 60721-3-3 | Class 3B3 on request |
| Ambient conditions / Resistance / Use in stationary industrial systems / to chemically active substances according to EN | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity |
| Ambient conditions / Resistance / Use in stationary industrial systems / to mechanically active substances according to EN | Yes; Class 3S4 incl. sand, dust, * |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to biologically active substances according to EN | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / 60721-3-5 | Class 5B3 on request |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to chemically active substances according to EN | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); * |
| Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to mechanically active substances according to EN | Yes; Class 5S3 incl. sand, dust; * |
| Ambient conditions / Resistance / Use on ships/at sea / to biologically active substances according to EN | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on |
| Ambient conditions / Resistance / Use on ships/at sea / 60721-3-6 | request |
| Ambient conditions / Resistance / Use on ships/at sea / to chemically active substances according to EN | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity |
| Ambient conditions / Resistance / Use on ships/at sea / to mechanically active substances according to EN | Yes; Class 6S3 incl. sand, dust; * |
| Ambient conditions / Resistance / Usage in industrial process technology / Against chemically active substances acc. to EN | Yes; Class 3 (excluding trichlorethylene) |
| Ambient conditions / Resistance / Usage in industrial process technology / Environmental conditions for process, measuring | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas |
| Ambient conditions / Resistance / Usage in industrial process technology / and control systems acc. to ANSI/ISA-71.04 | concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Ambient conditions / Resistance / Remark / conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Dimensions / Width | 80 mm |
| Dimensions / Height | 125 mm |
| Dimensions / Depth | 120 mm |
| Weights / Weight, approx. | 740 g |
| Product type designation | PS 305 |
| Output voltage | 24 V DC |
Connections and conditions of use
Before installation, verify the mechanical design and the designation of connected parts. Specifications for this version are listed in the table above.
Scope of supply
We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.
Frequently asked questions
Is the same product family enough to identify a replacement?
The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.
What information is needed to check connections and accessories?
Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.
Can you assess a faulty part?
Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.
Why buy from FOXON
Replacement part availability
We will check current part availability and confirm the possible delivery date before you order.
New original and refurbished parts
We will specify the available version and condition of the particular unit in the quotation.
Parts with a warranty
We will confirm the warranty period according to the part condition and specific quotation.
Diagnostics and repairs
For a faulty unit, we will check the options for diagnostics and professional repair.
Part conditions available for sale
Part conditions and warranty
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Sales, repairs and buyback of automation parts
We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.
Need to buy or repair this part?
Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.