6AG1305-1BA80-2AA0

6AG1305-1BA80-2AA0

Sales, Repair, Purchase

SIEMENS

SIPLUS S7-300 PS 305 based on 6ES7305-1BA80-0AA0 with conformal coating, -25ÔǪ+70 -¦C, stabilized power supply input: 24-110 V DC output: 24 V DC/2 A More

Code: 6AG1305-1BA80-2AA0

from 343 EUR excl. VAT (415,03 EUR Incl. VAT)
Total in stock: 4 pcs External stock 4 pcs
Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS S7-300 PS 305 based on 6ES7305-1BA80-0AA0 with conformal coating, -25ÔǪ+70 -¦C, stabilized power supply input: 24-110 V DC output: 24 V DC/2 A More

Code: 6AG1305-1BA80-2AA0

Part Sales 1

Condition Code Warranty Availability Delivery
Express?
Price excl. VAT
Refurbished (R) 6AG1305-1BA80-2AA0 R 12/24 months In external stock 4 pcs
Within 2-4 days / Express
On request

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1305-1BA80-2AA0 O 3-6 weeks 24 months On request Enquire a repair

6AG1305-1BA80-2AA0 – PS 305

SIPLUS S7-300 PS 305 based on 6ES7305-1BA80-0AA0 with conformal coating, -25…+70 °C, stabilized power supply input: 24-110 V DC output: 24 V DC/2 A

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
YesSupply voltage / Rated value (DC) / 24 V DC
YesSupply voltage / Rated value (DC) / 48 V DC
YesSupply voltage / Rated value (DC) / 72 V DC

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6AG1305-1BA80-2AA0
General information / based on6ES7305-1BA80-0AA0
Supply voltage / Rated value (DC) / 24 V DCYes
Supply voltage / Rated value (DC) / 48 V DCYes
Supply voltage / Rated value (DC) / 72 V DCYes
Supply voltage / Rated value (DC) / 96 V DCYes
Supply voltage / Rated value (DC) / 120 V DCYes; Rated value 110 V DC
Supply voltage / Mains buffering / Mains/voltage failure stored energy time10 ms; Corresponds to S2 and C1 of EN 50155
Supply voltage / Mains buffering / Repeat rate, min.1 s
Input current / Rated value at 24 V DC2.7 A
Input current / Rated value at 48 V DC1.3 A
Input current / Rated value at 72 V DC0.9 A
Input current / Rated value at 96 V DC0.65 A
Input current / Rated value at 110 V DC0.6 A
Input current / Inrush current, max.20 A
Input current / I²t5 A²·s
Input current / Leakage current, typ.0.7 mA
Input current / Leakage current, max.3.5 mA
Input current / Overcurrent overload capability270 ms on short circuit during startup and operation
Output voltage / Rated value (DC)24 V
Output voltage / permissible range, lower limit (DC)23.27 V
Output voltage / permissible range, upper limit (DC)24.72 V
Output voltage / Power up time, max.3 s
Output voltage / Residual ripple, typ.30 mV; Peak - peak
Output voltage / Residual ripple, max.150 mV; Peak - peak
Output current / Current output (rated value)2 A; 2 for connection in parallel
Output current / Short-circuit protectionYes; Electronic
Power / Active power input, typ.64 W
Power / Efficiency75 %
Power loss / Power loss, typ.16 W
Interrupts/diagnostics/status information / Diagnostics indication LED / Status indicator output 24 V OK (green)Yes
Potential separation / primary/secondaryYes; SELV output voltage Ua according to EN 60950-1 and EN 50178
Isolation / Isolation tested withRated insulation voltage (24 V against input): 150 V AC tested with: 2800 V DC
EMC / EMC interference immunityEN 61000-6-2
EMC / EMC interference emissionEN 55011 Class A
Degree and class of protection / Equipment protection classI
Ambient conditions / Ambient temperature during operation / min.-25 °C; = Tmin
Ambient conditions / Ambient temperature during operation / max.70 °C; = Tmax; for use on railway vehicles according to EN 50155, the rated temperature range -25 ... +55 °C (T1) or 60 °C @ UL/UL hazardous use applies
Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max.2 000 m
Ambient conditions / Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); above 2 000 m max. 75 V DC
Ambient conditions / Relative humidity / With condensation, tested in accordance with IEC 60068-100 %; RH incl. condensation/frost (no commissioning under condensation
Ambient conditions / Relative humidity / 2-38, max.conditions)
Ambient conditions / Resistance / Use in stationary industrial systems / to biologically active substances according to ENYes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna);
Ambient conditions / Resistance / Use in stationary industrial systems / 60721-3-3Class 3B3 on request
Ambient conditions / Resistance / Use in stationary industrial systems / to chemically active substances according to ENYes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity
Ambient conditions / Resistance / Use in stationary industrial systems / to mechanically active substances according to ENYes; Class 3S4 incl. sand, dust, *
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to biologically active substances according to ENYes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna);
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / 60721-3-5Class 5B3 on request
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to chemically active substances according to ENYes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); *
Ambient conditions / Resistance / Use on land craft, rail vehicles and special-purpose vehicles / to mechanically active substances according to ENYes; Class 5S3 incl. sand, dust; *
Ambient conditions / Resistance / Use on ships/at sea / to biologically active substances according to ENYes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on
Ambient conditions / Resistance / Use on ships/at sea / 60721-3-6request
Ambient conditions / Resistance / Use on ships/at sea / to chemically active substances according to ENYes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity
Ambient conditions / Resistance / Use on ships/at sea / to mechanically active substances according to ENYes; Class 6S3 incl. sand, dust; *
Ambient conditions / Resistance / Usage in industrial process technology / Against chemically active substances acc. to ENYes; Class 3 (excluding trichlorethylene)
Ambient conditions / Resistance / Usage in industrial process technology / Environmental conditions for process, measuringYes; Level GX group A/B (excluding trichlorethylene; harmful gas
Ambient conditions / Resistance / Usage in industrial process technology / and control systems acc. to ANSI/ISA-71.04concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Ambient conditions / Resistance / Remark / conditions acc. to EN 60721, EN 60654-4 andduring operation!
Dimensions / Width80 mm
Dimensions / Height125 mm
Dimensions / Depth120 mm
Weights / Weight, approx.740 g
Product type designationPS 305
Output voltage24 V DC

Connections and conditions of use

Before installation, verify the mechanical design and the designation of connected parts. Specifications for this version are listed in the table above.

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair