6AG1235-0KD22-2XB0

6AG1235-0KD22-2XB0

Sales, Repair, Purchase

SIEMENS

SIPLUS S7-200 EM235 -25...+70°C with conformal coating based on 6ES7235-0KD22-0XA0. analog I/O "only for S7-22X CPU "4 AE," "+/-10 V DC; 1 AO, DC +/- 12 bit" converter More

Code: 6AG1235-0KD22-2XB0

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS S7-200 EM235 -25...+70°C with conformal coating based on 6ES7235-0KD22-0XA0. analog I/O "only for S7-22X CPU "4 AE," "+/-10 V DC; 1 AO, DC +/- 12 bit" converter More

Code: 6AG1235-0KD22-2XB0

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1235-0KD22-2XB0 O 3-6 weeks 24 months On request Enquire a repair

6AG1235-0KD22-2XB0 – SIPLUS S7-200 EM 235

SIPLUS S7-200 EM 235.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair
71.2 mmDimensions / Width
4; DifferenceAnalog inputs / Number of analog inputs
30 VAnalog inputs / permissible input voltage for voltage input (destruction limit),

Application and selection

Compare the complete order number and specifications below with the original part and machine wiring. Check the design, interfaces, supply voltage or connection method as applicable to this product.

Technical specifications

ManufacturerSiemens
Order number6AG1235-0KD22-2XB0
Input current / from external supply (24 V DC), max.60 mA
Input current / from backplane bus 5 V DC, max.30 mA
Power loss / Power loss, typ.2 W
Analog inputs / Number of analog inputs4; Difference
Analog inputs / permissible input voltage for voltage input (destruction limit),30 V
Analog inputs / permissible input current for current input (destruction limit),32 mA
Analog inputs / Input ranges / VoltageYes
Analog inputs / Input ranges / CurrentYes
Analog inputs / Input ranges / ThermocoupleNo
Analog inputs / Input ranges / Resistance thermometerNo
Analog inputs / Input ranges / ResistanceNo
Analog inputs / Input ranges (rated values), voltages / 0 to +50 mVYes
Analog inputs / Input ranges (rated values), voltages / 0 to +100 mVYes
Analog inputs / Input ranges (rated values), voltages / 0 to +500 mVYes
Analog inputs / Input ranges (rated values), voltages / 0 to +1 VYes
Analog inputs / Input ranges (rated values), voltages / 0 to +5 VYes
Analog inputs / Input ranges (rated values), voltages / 0 to +10 VYes
Analog inputs / Input ranges (rated values), voltages / -1 V to +1 VYes
Analog inputs / Input ranges (rated values), voltages / -10 V to +10 VYes
Analog inputs / Input ranges (rated values), voltages / -100 mV to +100 mVYes
Analog inputs / Input ranges (rated values), voltages / -2.5 V to +2.5 VYes
Analog inputs / Input ranges (rated values), voltages / -25 mV to +25 mVYes
Analog inputs / Input ranges (rated values), voltages / -250 mV to +250 mVYes
Analog inputs / Input ranges (rated values), voltages / -5 V to +5 VYes
Analog inputs / Input ranges (rated values), voltages / -50 mV to +50 mVYes
Analog inputs / Input ranges (rated values), voltages / -500 mV to +500 mVYes
Analog inputs / Input ranges (rated values), currents / 0 to 20 mAYes
Analog outputs / Number of analog outputs1
Analog outputs / Output ranges, voltage / -10 V to +10 VYes
Analog outputs / Output ranges, current / 0 to 20 mAYes
Analog outputs / Load impedance (in rated range of output) / with voltage outputs, min.5 kΩ
Analog outputs / Load impedance (in rated range of output) / with current outputs, max.0.5 kΩ
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.12 bit
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic conversion time (ms)< 0.25 ms
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Interference voltage suppression for interference40 dB, DC to 60 Hz
Analog value generation for the inputs / Displayable conversion value range / bipolar signals-32 000 to +32 000
Analog value generation for the inputs / Displayable conversion value range / unipolar signals0 to 32 000
Analog value generation for the outputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.11 bit
Analog value generation for the outputs / Settling time / for voltage output100 µs
Analog value generation for the outputs / Settling time / for current output2 ms
Analog value generation for the outputs / Displayable conversion value range / bipolar signals-32 000 to +32 000
Analog value generation for the outputs / Displayable conversion value range / unipolar signals0 to 32 000
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Voltage, relative to output range, (+/-)0.5 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to output range, (+/-)0.5 %
Errors/accuracies / Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency / Common mode voltage, max.12 V
Interrupts/diagnostics/status information / Diagnostics indication LED / external fault EXTF (red)Yes
Potential separation / Potential separation analog inputs / Potential separation analog inputsNo
Potential separation / Potential separation analog outputs / Potential separation analog outputsNo
Connection method / Plug-in I/O terminalsNo
Dimensions / Width71.2 mm
Dimensions / Height80 mm
Dimensions / Depth62 mm
Weights / Weight, approx.186 g
Product type designationSIPLUS S7-200 EM 235
Base module explicitly specified by Siemens6ES7235-0KD22-0XA0
Ambient temperature and condensation conditions-25 to +70 °C; -25 to +55 °C (for applications with cUL approval), condensation permissible
Product descriptionSiemens SIPLUS S7-200 EM 235.

Connections and conditions of use

  • Input current / from external supply (24 V DC), max.: 60 mA
  • Input current / from backplane bus 5 V DC, max.: 30 mA
  • Analog inputs / permissible input voltage for voltage input (destruction limit),: 30 V
  • Analog inputs / permissible input current for current input (destruction limit),: 32 mA
  • Analog inputs / Input ranges / Voltage: Yes
  • Analog inputs / Input ranges / Current: Yes
  • Analog inputs / Input ranges (rated values), voltages / 0 to +50 mV: Yes
  • Analog inputs / Input ranges (rated values), voltages / 0 to +100 mV: Yes

Scope of supply

We will confirm the exact version, package contents and related accessories before ordering. Package information in the technical table applies to the stated order number.

Frequently asked questions

Is the same product family enough to identify a replacement?

The complete order number is essential. If the type changes, compare the electrical and mechanical design, connections and requirements of the original application.

What information is needed to check connections and accessories?

Send a nameplate photo, the designations of related modules and connectors and, where needed, a wiring diagram. We will check the specific version for your application.

Can you assess a faulty part?

Yes. Send the complete order number and a description of the fault. We will check the diagnostic and professional repair options for your specific unit.

Why buy from FOXON

1

Replacement part availability

We will check current part availability and confirm the possible delivery date before you order.

2

New original and refurbished parts

We will specify the available version and condition of the particular unit in the quotation.

3

Parts with a warranty

We will confirm the warranty period according to the part condition and specific quotation.

4

Diagnostics and repairs

For a faulty unit, we will check the options for diagnostics and professional repair.

More than 3,500customers
We deliver tomore than 100 countries
Express delivery?We will check. Contact us now.

Part conditions available for sale

Part conditions and warranty
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Sales, repairs and buyback of automation parts

We supply replacement parts for industrial automation and assess faulty units for diagnostics and repair. We also buy surplus parts. Send the exact designation and required quantity.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the complete order number, quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair