SIPLUS S7-1200 CPU 1211C DC/DC/relay based on 6ES7211-1HE31-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, signal board: 0, compact CPU, DC/DC/RY, onboard I/O: 6 DI 24 V DC 4 DQ relay 2 A 2 AI 0-10 V DC power supply: AC 20.4-28.8V DC program/data memory 30 KB More

Code: 6AG1211-1HE31-2XB0

Variant does not exist

Rezervace termínu

Get a quote
SIEMENS

SIPLUS S7-1200 CPU 1211C DC/DC/relay based on 6ES7211-1HE31-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, signal board: 0, compact CPU, DC/DC/RY, onboard I/O: 6 DI 24 V DC 4 DQ relay 2 A 2 AI 0-10 V DC power supply: AC 20.4-28.8V DC program/data memory 30 KB More

Code: 6AG1211-1HE31-2XB0

Repair of the part

Name Code Delivery Warranty Price excl. VAT
Complete part repair 6AG1211-1HE31-2XB0 O 3-6 weeks 24 months On request Enquire a repair

6AG1211-1HE31-2XB0 – CPU 1211C DC/DC/relay

Siemens 6AG1211-1HE31-2XB0: SIPLUS S7-1200 CPU 1211C DC/DC/relay based on 6ES7211- 1HE31-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, signal board: 0, compact CPU, DC/DC/RY, onboard I/O: 6 DI 24 V DC 4 DQ relay 2 A 2 AI 0-10 V DC power supply: AC 20.4-28.8V DC program/data memory 30 KB.

Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.

Request a quote for purchase or repair

Technical specifications

ManufacturerSiemens
Order number6AG1211-1HE31-2XB0
Product typeCPU 1211C DC/DC/relay
Supply voltage / Rated value (DC) / 24 V DCYes
Supply voltage / Load voltage L+ / Rated value (DC)24 V
Input current / Current consumption (rated value)300 mA; Typical
Work memory / integrated30 kbyte
Digital inputs / Number of digital inputs6; Integrated
Digital inputs / Input voltage / Rated value (DC)24 V
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / parameterizable0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", min.0.2 ms
Digital inputs / Input delay (for rated value of input voltage) / for standard inputs / at "0" to "1", max.12.8 ms
Digital inputs / Input delay (for rated value of input voltage) / for technological functions / ParameterizableSingle phase : 3 @ 100 kHz, differential: 3 @ 80 kHz
Digital inputs / Cable length / shielded, max.500 m; 50 m for technological functions
Digital inputs / Cable length / unshielded, max.300 m; for technological functions: No
Digital outputs / Number of digital outputs4; Relays
Digital outputs / Cable length / shielded, max.500 m
Digital outputs / Cable length / unshielded, max.150 m
Analog inputs / Number of analog inputs2
Analog inputs / Input ranges (rated values), voltages / 0 to +10 VYes
Analog inputs / Input ranges (rated values), voltages / Input resistance (0 to 10 V)≥100k ohms
Analog inputs / Cable length / shielded, max.100 m; twisted and shielded
Analog outputs / Number of analog outputs0
Ambient temperature during operation / min.-40 °C; = Tmin; Startup @ -25 °C
Ambient temperature during operation / max.70 °C; = Tmax; > +60 °C Number of simultaneously controllable inputs and outputs max. 50 %; no signal board can be used
Ambient temperature during operation / horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
Ambient temperature during operation / horizontal installation, max.70 °C; = Tmax; > +60 °C Number of simultaneously controllable inputs and outputs max. 50 %; no signal board can be used
Ambient temperature during operation / vertical installation, min.-40 °C; = Tmin; Startup @ -25 °C
Ambient temperature during operation / vertical installation, max.50 °C; = Tmax
Ambient temperature during operation / At cold restart, min.-25 °C
Part variants and further information
  • New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
  • New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
  • New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
  • New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
  • Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
  • Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
  • Used (U): Functional used part. 3-month warranty.

Buy parts and arrange repairs with FOXON

We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.

More about parts sales, repairs and buyback

Need to buy or repair this part?

Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.

Request a quote for purchase or repair