6AG1210-1PE26-2AL0
- SIEMENS
- SIMATIC ET 200 / DP
- 6AG1210-1PE26-2AL0
6AG1210-1PE26-2AL0
SIPLUS G120 PM240-2 IP20-FSD-A-400V 30 kW based on 6SL3210-1PE26-0AL0 with conformal coating, -20…+50 °C, with integrated class A filter with integrated braking chopper 380-480 V 3 AC +10/-20% 47-63 Hz power high overload: 22 kW at 200% 3 s,150% 57 s,100% 240 s power low overload: 30 kW at 150% 3 s,110% 57 s,100% 240 s 472x 200x 237 (HxWxD), design FSD, degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8 More
Code: 6AG1210-1PE26-2AL0
SIPLUS G120 PM240-2 IP20-FSD-A-400V 30 kW based on 6SL3210-1PE26-0AL0 with conformal coating, -20…+50 °C, with integrated class A filter with integrated braking chopper 380-480 V 3 AC +10/-20% 47-63 Hz power high overload: 22 kW at 200% 3 s,150% 57 s,100% 240 s power low overload: 30 kW at 150% 3 s,110% 57 s,100% 240 s 472x 200x 237 (HxWxD), design FSD, degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8 More
Code: 6AG1210-1PE26-2AL0
Repair of the part
| Name | Code | Delivery | Warranty | Price excl. VAT | |
|---|---|---|---|---|---|
| Complete part repair | 6AG1210-1PE26-2AL0 O | 3-6 weeks | 24 months | On request | Enquire a repair |
6AG1210-1PE26-2AL0 – PM240-2
Siemens 6AG1210-1PE26-2AL0: SIPLUS G120 PM240-2 IP20-FSD-A-400V 30 kW based on 6SL3210-1PE26-0AL0 with conformal coating, -20…+50 °C, with integrated class A filter with integrated braking chopper 380-480 V 3 AC +10/-20% 47-63 Hz power high overload: 22 kW at 200% 3 s,150% 57 s,100% 240 s power low overload: 30 kW at 150% 3 s,110% 57 s,100% 240 s 472x 200x 237 (HxWxD), design FSD, degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8.
Need to buy or repair this part?
We will check replacement part availability and the options for diagnosing and repairing your faulty unit.
Technical specifications
| Manufacturer | Siemens |
|---|---|
| Order number | 6AG1210-1PE26-2AL0 |
| Product type | PM240-2 |
| Input current / Input current with low overload | 57 A |
| Input current / Input current with high overload | 47 A |
| Output current / Output current, max. | 90 A |
| Output current / Output current without overload | 60 A |
| Output current / Output current with low overload | 60 A |
| Output current / Output current with high overload | 45 A |
| Power loss / Power loss, max. | 0.77 kW |
| Power loss / Power loss of the CDM in standby mode | 27 W |
| Power loss / Power loss of the CDM at the operating point (0/25) | 279 W |
| Power loss / Power loss of the CDM at the operating point (0/50) | 357 W |
| Power loss / Power loss of the CDM at the operating point (0/100) | 603 W |
| Power loss / Power loss of the CDM at the operating point (50/25) | 295 W |
| Power loss / Power loss of the CDM at the operating point (50/50) | 395 W |
| Power loss / Power loss of the CDM at the operating point (50/100) | 698 W |
| Power loss / Power loss of the CDM at the operating point (90/50) | 445 W |
| Power loss / Power loss of the CDM at the operating point (90/100) | 848 W |
| Power loss / Relative power loss of the CDM at the operating point (0/25) | 0.67 % |
| Power loss / Relative power loss of the CDM at the operating point (0/50) | 0.86 % |
| Power loss / Relative power loss of the CDM at the operating point (0/100) | 1.45 % |
| Ambient temperature during operation / min. | -20 °C; = Tmin |
| Ambient temperature during operation / max. | 50 °C; = Tmax |
| Cables / Cable length for motor, shielded, max. | 200 m |
| Cables / Cable length for braking resistor, max. | 10 m |
| Width | 200 mm |
| Height | 472 mm |
| Depth | 237 mm |
| Weights / Weight (without packaging) | 18.5 kg |
Part variants and further information
- New, sealed (NC): Brand-new, unused part in unopened original packaging. 12-month warranty.
- New, opened (NO): Brand-new and unused part, but the original packaging has been opened. 12-month warranty.
- New, without packaging (NW): Brand-new and unused part, supplied without original packaging. 12-month warranty.
- New (N): New and unused part, typically smaller components supplied in multi-packs in one original package. 12-month warranty.
- Refurbished (R): Part has been removed from service, cleaned, inspected and tested to meet original functionality and quality. 12-month warranty.
- Used, tested (T): Functional used part that has passed full testing. 6-month warranty.
- Used (U): Functional used part. 3-month warranty.


Buy parts and arrange repairs with FOXON
We supply new original and refurbished parts with a warranty. We confirm current availability and the possible delivery date before you place an order. For faulty parts, we check the options for diagnostics and professional repair.
Need to buy or repair this part?
Send the full order number, required quantity and, for repairs, a description of the fault. We will prepare a quotation within 1 hour.
Request a quote for purchase or repairHighlighted items are mandatory.