The ADFweb HD67818-KNX-B2 connects a KNX TP bus to a PROFINET control system. As a PROFINET Slave, it exchanges process data with a supervisory PLC and maps it to KNX telegrams. More

Code: HD67818-KNX-B2

499 EUR excl. VAT (603,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67818-KNX-B2 connects a KNX TP bus to a PROFINET control system. As a PROFINET Slave, it exchanges process data with a supervisory PLC and maps it to KNX telegrams. More

Code: HD67818-KNX-B2

ADFweb HD67818-KNX-B2

PROFINET Slave / KNX

The ADFweb HD67818-KNX-B2 connects a KNX TP bus to a PROFINET control system. As a PROFINET Slave, it exchanges process data with a supervisory PLC and maps it to KNX telegrams.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
PROFINET Slave / KNXProtocol connection
1440 bytes in each directionData capacity
SW67818Configuration tool

Converter applications

Use it to read KNX states and values in a PLC and transfer PLC commands to KNX. It supports up to 1,440 bytes for reading and 1,440 bytes for writing.

Technical specifications HD67818-KNX-B2

Order codeHD67818-KNX-B2
Protocol connectionPROFINET Slave / KNX
Roles and versionPROFINET Slave; KNX TP
Interfaces and portsKNX TP; Ethernet RJ45
KNX TP data rate9 600 bit/s
Data capacity1440 bytes in each direction
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67818

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67818, configure PROFINET, the KNX address, group addresses and data mapping. The software generates an XML file for import into the PROFINET Master project; process data must match the PLC project.

The PROFINET side requires a supervisory Master. To connect PROFINET Slave devices without another PLC, choose the Master model HD67B79-KNX-B2. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67818-KNX-B2
Dimensional drawing of the version shown - HD67818-KNX-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The PROFINET side requires a supervisory Master. To connect PROFINET Slave devices without another PLC, choose the Master model HD67B79-KNX-B2. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.

How is this converter configured?

In SW67818, configure PROFINET, the KNX address, group addresses and data mapping. The software generates an XML file for import into the PROFINET Master project; process data must match the PLC project.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The PROFINET side requires a supervisory Master. To connect PROFINET Slave devices without another PLC, choose the Master model HD67B79-KNX-B2. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.

Converter enquiry HD67818-KNX-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67818-KNX-B2

Order codeHD67818-KNX-B2
Protocol connectionPROFINET Slave / KNX
Roles and versionPROFINET Slave; KNX TP
Interfaces and portsKNX TP; Ethernet RJ45
KNX TP data rate9 600 bit/s
Data capacity1440 bytes in each direction
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67818

For an older device, check the hardware version and connections against its label.