Converter OPC UA Client / Modbus TCP Server - HD67B10-B2

Converter OPC UA Client / Modbus TCP Server - HD67B10-B2


ADFweb

The ADFweb HD67B10-B2 makes values from OPC UA Servers available to a Modbus TCP Client. It accesses OPC UA Servers as a Client and provides data as a Server on the Modbus TCP side. More

Code: HD67B10-B2

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67B10-B2 makes values from OPC UA Servers available to a Modbus TCP Client. It accesses OPC UA Servers as a Client and provides data as a Server on the Modbus TCP side. More

Code: HD67B10-B2

ADFweb HD67B10-B2

OPC UA Client / Modbus TCP Server

The ADFweb HD67B10-B2 makes values from OPC UA Servers available to a Modbus TCP Client. It accesses OPC UA Servers as a Client and provides data as a Server on the Modbus TCP side.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
OPC UA Client / Modbus TCP ServerProtocol connection
1500 bytes in each directionData capacity
SW67B10Configuration tool

Converter applications

Use it to connect a PLC, HMI or another Modbus TCP Client application to OPC UA Server data. It supports up to 1,500 bytes for reading and 1,500 bytes for writing; registers must match the OPC UA variables and data types.

Technical specifications HD67B10-B2

Order codeHD67B10-B2
Protocol connectionOPC UA Client / Modbus TCP Server
Converter rolesOPC UA Client; Modbus TCP Slave/Server
Interfaces and portsEthernet RJ45
Data capacity1500 bytes in each direction
Power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC4 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67B10

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.

Communication and configuration

In SW67B10, configure network addresses, the Modbus TCP Server and the OPC UA Server list. Select variables for reading and writing and map them to registers accessible from the Modbus TCP Client application.

This model is an OPC UA Client and a Modbus TCP Server. A different converter is required for the opposite roles. Before commissioning, check register addressing, byte order and security on the connected OPC UA Server.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67B10-B2
Dimensional drawing of the version shown - HD67B10-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This model is an OPC UA Client and a Modbus TCP Server. A different converter is required for the opposite roles. Before commissioning, check register addressing, byte order and security on the connected OPC UA Server.

How is this converter configured?

In SW67B10, configure network addresses, the Modbus TCP Server and the OPC UA Server list. Select variables for reading and writing and map them to registers accessible from the Modbus TCP Client application.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This model is an OPC UA Client and a Modbus TCP Server. A different converter is required for the opposite roles. Before commissioning, check register addressing, byte order and security on the connected OPC UA Server.

Converter enquiry HD67B10-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67B10-B2

Order codeHD67B10-B2
Protocol connectionOPC UA Client / Modbus TCP Server
Converter rolesOPC UA Client; Modbus TCP Slave/Server
Interfaces and portsEthernet RJ45
Data capacity1500 bytes in each direction
Power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC4 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67B10

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.