Converter Modbus TCP Server / DALI - HD67845-B2
Converter Modbus TCP Server / DALI - HD67845-B2
The ADFweb HD67845-B2 exposes DALI lighting to a Modbus TCP Client system. It operates as a Modbus TCP Server and responds to requests from the supervisory device. More
Code: HD67845-B2
The ADFweb HD67845-B2 exposes DALI lighting to a Modbus TCP Client system. It operates as a Modbus TCP Server and responds to requests from the supervisory device. More
Code: HD67845-B2
ADFweb HD67845-B2
Modbus TCP Server / DALI
The ADFweb HD67845-B2 exposes DALI lighting to a Modbus TCP Client system. It operates as a Modbus TCP Server and responds to requests from the supervisory device.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Use it to control and monitor DALI lighting from a PLC or supervisory Modbus application. According to its configured mapping, it transfers luminaire states and commands for light levels, groups and scenes.
Technical specifications HD67845-B2
| Order code | HD67845-B2 |
|---|---|
| Protocol connection | Modbus TCP Server / DALI |
| Roles and version | Modbus TCP Server; DALI |
| Interfaces and ports | DALI; Ethernet RJ45 |
| DALI capacity | up to 64 devices |
| DALI data rate | 1 200 bit/s |
| DALI bus power | Version -Y with bus power; -N without bus power. Select before ordering. |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 60 × 35 × 95 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67845; DALI Console |
For an older device, check the hardware version and connections against its label.
Communication and configuration
In SW67845, configure Modbus TCP network settings, connected DALI nodes and register mapping. Use DALI Console to prepare addresses, groups and scenes and test communication with luminaires.
An external Modbus TCP Client must initiate reads and writes. Independent polling of other Modbus Slave/Server devices requires a model with the opposite communication role. The base code HD67845-B2 does not specify DALI bus power. Before ordering, we will select HD67845-B2-Y with DALI bus power or HD67845-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. An external Modbus TCP Client must initiate reads and writes. Independent polling of other Modbus Slave/Server devices requires a model with the opposite communication role. The base code HD67845-B2 does not specify DALI bus power. Before ordering, we will select HD67845-B2-Y with DALI bus power or HD67845-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.
How is this converter configured?
In SW67845, configure Modbus TCP network settings, connected DALI nodes and register mapping. Use DALI Console to prepare addresses, groups and scenes and test communication with luminaires.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
An external Modbus TCP Client must initiate reads and writes. Independent polling of other Modbus Slave/Server devices requires a model with the opposite communication role. The base code HD67845-B2 does not specify DALI bus power. Before ordering, we will select HD67845-B2-Y with DALI bus power or HD67845-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.
Converter enquiry HD67845-B2
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67845-B2
| Order code | HD67845-B2 |
|---|---|
| Protocol connection | Modbus TCP Server / DALI |
| Roles and version | Modbus TCP Server; DALI |
| Interfaces and ports | DALI; Ethernet RJ45 |
| DALI capacity | up to 64 devices |
| DALI data rate | 1 200 bit/s |
| DALI bus power | Version -Y with bus power; -N without bus power. Select before ordering. |
| Converter power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 60 × 35 × 95 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67845; DALI Console |