Converter OPC UA Server / KNX - HD67B41-B2

Converter OPC UA Server / KNX - HD67B41-B2


ADFweb

The ADFweb HD67B41-B2 exposes KNX TP bus values to OPC UA Client applications. As an OPC UA Server, it provides configured variables and maps their values to KNX telegrams. More

Code: HD67B41-B2

499 EUR excl. VAT (603,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67B41-B2 exposes KNX TP bus values to OPC UA Client applications. As an OPC UA Server, it provides configured variables and maps their values to KNX telegrams. More

Code: HD67B41-B2

ADFweb HD67B41-B2

OPC UA Server / KNX

The ADFweb HD67B41-B2 exposes KNX TP bus values to OPC UA Client applications. As an OPC UA Server, it provides configured variables and maps their values to KNX telegrams.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
OPC UA Server / KNXProtocol connection
1500 bytes in each directionData capacity
SW67B41Configuration tool

Converter applications

Use it to link KNX values and commands to a supervisory application operating as an OPC UA Client. It supports up to 1,500 bytes for reading and 1,500 bytes for writing.

Technical specifications HD67B41-B2

Order codeHD67B41-B2
Protocol connectionOPC UA Server / KNX
Roles and versionOPC UA Server; KNX TP
Interfaces and portsKNX TP; Ethernet RJ45
KNX TP data rate9 600 bit/s
Data capacity1500 bytes in each direction
Converter power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC4 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67B41

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.

Communication and configuration

In SW67B41, configure OPC UA communication and variables, including name, data type, length and read/write access. Define KNX group addresses and telegrams and map them to OPC UA variables.

The OPC UA peer must operate as a Client. Before ordering, match the required data types and security to the specific application and converter firmware. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67B41-B2
Dimensional drawing of the version shown - HD67B41-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The OPC UA peer must operate as a Client. Before ordering, match the required data types and security to the specific application and converter firmware. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.

How is this converter configured?

In SW67B41, configure OPC UA communication and variables, including name, data type, length and read/write access. Define KNX group addresses and telegrams and map them to OPC UA variables.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The OPC UA peer must operate as a Client. Before ordering, match the required data types and security to the specific application and converter firmware. The converter uses a TP bus on the KNX side. Prepare group addresses, data types and the required transfer direction; check the power supply for both the KNX bus and the converter.

Converter enquiry HD67B41-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67B41-B2

Order codeHD67B41-B2
Protocol connectionOPC UA Server / KNX
Roles and versionOPC UA Server; KNX TP
Interfaces and portsKNX TP; Ethernet RJ45
KNX TP data rate9 600 bit/s
Data capacity1500 bytes in each direction
Converter power supplyConfirm against the label and hardware version before ordering
Consumption at 24 V DC4 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67B41

We will confirm the supply range for this model against the specific hardware version. Always check the device label before connecting the power supply.