Converter Modbus TCP Server / M-Bus Master - HD67044-B2-80

Converter Modbus TCP Server / M-Bus Master - HD67044-B2-80


ADFweb

The ADFweb HD67044-B2-80 exposes M-Bus meter values to a system using Modbus TCP Server. As an M-Bus Master, it reads configured values and stores them in registers accessible to the supervisory Modbus system. More

Code: HD67044-B2-80

399 EUR excl. VAT (482,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67044-B2-80 exposes M-Bus meter values to a system using Modbus TCP Server. As an M-Bus Master, it reads configured values and stores them in registers accessible to the supervisory Modbus system. More

Code: HD67044-B2-80

ADFweb HD67044-B2-80

Modbus TCP Server / M-Bus Master

The ADFweb HD67044-B2-80 exposes M-Bus meter values to a system using Modbus TCP Server. As an M-Bus Master, it reads configured values and stores them in registers accessible to the supervisory Modbus system.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
Modbus TCP Server / M-Bus MasterProtocol connection
35 mm DIN railHardware version
SW67044Configuration tool

Converter applications

Use it to collect values from up to 80 standard M-Bus devices in a PLC or supervisory application. An external Modbus Master or Client sends register requests; size the meter installation according to its bus loading.

Technical specifications HD67044-B2-80

Order codeHD67044-B2-80
Protocol connectionModbus TCP Server / M-Bus Master
Converter rolesModbus TCP Server; M-Bus Master
Interfaces and portsM-Bus; Ethernet RJ45
M-Bus line capacityup to 80 standard M-Bus devices
Power supply15-21 V AC / 18-35 V DC
Consumption at 24 V DC, no load / full load3.5 W / 8 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the housing shown (D × W × H)60 × 71 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67044

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67044, configure M-Bus communication, meter addresses and the variables to read. Define Modbus register mapping and data formats. For Modbus TCP, configure the Ethernet network parameters.

This model provides a Modbus TCP Server. An external Modbus TCP Client is required to read its registers. Prepare the meter list and their telegrams to check the available values.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Shared housing of the HD67044-B2 series; illustrative label. Capacity is defined by order code HD67044-B2-80.
Shared housing of the HD67044-B2 series; illustrative label. Capacity is defined by order code HD67044-B2-80.

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This model provides a Modbus TCP Server. An external Modbus TCP Client is required to read its registers. Prepare the meter list and their telegrams to check the available values.

How is this converter configured?

In SW67044, configure M-Bus communication, meter addresses and the variables to read. Define Modbus register mapping and data formats. For Modbus TCP, configure the Ethernet network parameters.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This model provides a Modbus TCP Server. An external Modbus TCP Client is required to read its registers. Prepare the meter list and their telegrams to check the available values.

Converter enquiry HD67044-B2-80

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67044-B2-80

Order codeHD67044-B2-80
Protocol connectionModbus TCP Server / M-Bus Master
Converter rolesModbus TCP Server; M-Bus Master
Interfaces and portsM-Bus; Ethernet RJ45
M-Bus line capacityup to 80 standard M-Bus devices
Power supply15-21 V AC / 18-35 V DC
Consumption at 24 V DC, no load / full load3.5 W / 8 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the housing shown (D × W × H)60 × 71 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67044

For an older device, check the hardware version and connections against its label.