Converter Modbus RTU Slave / DALI - HD67843-B2

Converter Modbus RTU Slave / DALI - HD67843-B2


ADFweb

The ADFweb HD67843-B2 exposes DALI lighting to a Modbus RTU Master system. It operates as a Modbus RTU Slave and responds to requests from the supervisory device. More

Code: HD67843-B2

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67843-B2 exposes DALI lighting to a Modbus RTU Master system. It operates as a Modbus RTU Slave and responds to requests from the supervisory device. More

Code: HD67843-B2

ADFweb HD67843-B2

Modbus RTU Slave / DALI

The ADFweb HD67843-B2 exposes DALI lighting to a Modbus RTU Master system. It operates as a Modbus RTU Slave and responds to requests from the supervisory device.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
Modbus RTU Slave / DALIProtocol connection
DALI; RS485Hardware version
SW67843Configuration tool

Converter applications

Use it to control and monitor DALI lighting from a PLC or supervisory Modbus application. According to its configured mapping, it transfers luminaire states and commands for light levels, groups and scenes.

Technical specifications HD67843-B2

Order codeHD67843-B2
Protocol connectionModbus RTU Slave / DALI
Roles and versionModbus RTU Slave; DALI
Interfaces and portsDALI; RS485; Ethernet RJ45 for configuration
DALI capacityup to 64 devices
DALI data rate1 200 bit/s
Modbus RTU data rateup to 115,200 bit/s
DALI bus powerVersion -Y with bus power; -N without bus power. Select before ordering.
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67843; DALI Console

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67843, configure RS485 baud rate, parity and addresses, connected DALI nodes and register mapping. Use DALI Console to prepare addresses, groups and scenes and test communication with luminaires. Ethernet is used for configuration and updates.

An external Modbus RTU Master must initiate reads and writes. Independent polling of other Modbus Slave/Server devices requires a model with the opposite communication role. The base code HD67843-B2 does not specify DALI bus power. Before ordering, we will select HD67843-B2-Y with DALI bus power or HD67843-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67843-B2
Dimensional drawing of the version shown - HD67843-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. An external Modbus RTU Master must initiate reads and writes. Independent polling of other Modbus Slave/Server devices requires a model with the opposite communication role. The base code HD67843-B2 does not specify DALI bus power. Before ordering, we will select HD67843-B2-Y with DALI bus power or HD67843-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.

How is this converter configured?

In SW67843, configure RS485 baud rate, parity and addresses, connected DALI nodes and register mapping. Use DALI Console to prepare addresses, groups and scenes and test communication with luminaires. Ethernet is used for configuration and updates.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

An external Modbus RTU Master must initiate reads and writes. Independent polling of other Modbus Slave/Server devices requires a model with the opposite communication role. The base code HD67843-B2 does not specify DALI bus power. Before ordering, we will select HD67843-B2-Y with DALI bus power or HD67843-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.

Converter enquiry HD67843-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67843-B2

Order codeHD67843-B2
Protocol connectionModbus RTU Slave / DALI
Roles and versionModbus RTU Slave; DALI
Interfaces and portsDALI; RS485; Ethernet RJ45 for configuration
DALI capacityup to 64 devices
DALI data rate1 200 bit/s
Modbus RTU data rateup to 115,200 bit/s
DALI bus powerVersion -Y with bus power; -N without bus power. Select before ordering.
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67843; DALI Console

For an older device, check the hardware version and connections against its label.