Converter EtherCAT Slave / Modbus TCP Server - HD67E04-A1

Converter EtherCAT Slave / Modbus TCP Server - HD67E04-A1


ADFweb

The ADFweb HD67E04-A1 connects an EtherCAT control system to a Modbus TCP Client. It operates as an EtherCAT Slave and provides data as a Server on the Modbus TCP side. More

Code: HD67E04-A1

249 EUR excl. VAT (301,29 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67E04-A1 connects an EtherCAT control system to a Modbus TCP Client. It operates as an EtherCAT Slave and provides data as a Server on the Modbus TCP side. More

Code: HD67E04-A1

ADFweb HD67E04-A1

EtherCAT Slave / Modbus TCP Server

The ADFweb HD67E04-A1 connects an EtherCAT control system to a Modbus TCP Client. It operates as an EtherCAT Slave and provides data as a Server on the Modbus TCP side.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
EtherCAT Slave / Modbus TCP ServerProtocol connection
35 mm DIN railHardware version
SW67E04Configuration tool

Converter applications

Use it to exchange process values between an EtherCAT Master and a Modbus TCP Client, such as a second control system. Both sides need matching data areas and the same interpretation of registers and variables.

Technical specifications HD67E04-A1

Order codeHD67E04-A1
Protocol connectionEtherCAT Slave / Modbus TCP Server
Converter rolesEtherCAT Slave; Modbus TCP Slave/Server
Interfaces and ports2× EtherCAT RJ45 (IN/OUT); 2× Ethernet RJ45 for Modbus TCP and configuration
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)120 × 23 × 107 mm
Device weightapproximately 200 g
Configuration softwareSW67E04

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67E04, configure the Modbus TCP Server and EtherCAT read/write variables. The software exports an ESI file for the EtherCAT Master; align its data areas with Modbus TCP register mapping.

This model does not independently poll other Modbus TCP Servers. It requires a connected Modbus TCP Client and EtherCAT Master. EtherCAT and Ethernet port pairs are not interchangeable.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67E04-A1
Dimensional drawing of the version shown - HD67E04-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This model does not independently poll other Modbus TCP Servers. It requires a connected Modbus TCP Client and EtherCAT Master. EtherCAT and Ethernet port pairs are not interchangeable.

How is this converter configured?

In SW67E04, configure the Modbus TCP Server and EtherCAT read/write variables. The software exports an ESI file for the EtherCAT Master; align its data areas with Modbus TCP register mapping.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This model does not independently poll other Modbus TCP Servers. It requires a connected Modbus TCP Client and EtherCAT Master. EtherCAT and Ethernet port pairs are not interchangeable.

Converter enquiry HD67E04-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67E04-A1

Order codeHD67E04-A1
Protocol connectionEtherCAT Slave / Modbus TCP Server
Converter rolesEtherCAT Slave; Modbus TCP Slave/Server
Interfaces and ports2× EtherCAT RJ45 (IN/OUT); 2× Ethernet RJ45 for Modbus TCP and configuration
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)120 × 23 × 107 mm
Device weightapproximately 200 g
Configuration softwareSW67E04

For an older device, check the hardware version and connections against its label.