Ethernet IO remote digital inputs outputs 24V: 12xDI, 8xDO relay, Modbus TCP, REST, MQTT, OPC UA

Ethernet IO remote digital inputs outputs 24V: 12xDI, 8xDO relay, Modbus TCP, REST, MQTT, OPC UA


W&T

Industrial module for remote control, monitoring and collection of digital signals 12x DI and 8x DO via Ethernet, OPC UA, Modbus TCP, MQTT, REST or Web server. Alarm system with email notification, automatic control of outputs according to input, power supply 12-24 VDC, DIN mounting. More

Code: 57738

448 EUR excl. VAT (542,08 EUR Incl. VAT)
Recycling fee 0,04 EUR included in the price.
Quantity discount
Units
Discount
Price without VAT

0 - 4
0%
448,00

5 - 9
2%
439,04

10 - 19
5%
425,60

20 and more
9%
407,68

In stock
pcs
(2 pcs In stock)

Rezervace termínu

Get a quote
W&T

Industrial module for remote control, monitoring and collection of digital signals 12x DI and 8x DO via Ethernet, OPC UA, Modbus TCP, MQTT, REST or Web server. Alarm system with email notification, automatic control of outputs according to input, power supply 12-24 VDC, DIN mounting. More

Code: 57738

W&T 57738

12 inputs and 8 relay outputs via Ethernet

The W&T 57738 connects 12 digital inputs (DI) and 8 relays to a 10/100BaseT Ethernet network. It enables monitoring and control via a web interface and integration into higher-level systems using OPC UA, MQTT, REST or Modbus TCP.

Do you need to select or order W&T 57738?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.

Enquire about purchasing or repairing a part
12× DI + 8× relaysDigital signals over Ethernet
24 V AC/DC, 2 ATake into account the type and load of the output
PoE or 12–24 V DCPower supply according to the specific model

Usage

The module is used for collecting status signals, fault reporting and remote control within industrial or technical infrastructure. Statuses can be displayed in a browser, transferred to a visualisation system or used in pre-defined actions.

Technical specifications for W&T 57738

Digital outputs8× potential-free contacts, max. 24 V DC / 2 A or 24 V AC / 2 A
With suitable isolating relays, voltages of up to
230 V.
Digital inputs12× digital inputs
Maximum input voltage ±30 V
Reverse polarity protection within this range
Switching threshold 4 V ± 0.5 V
Current when switched on = 2.2 mA
Integrated 32-bit pulse counter
Network interfaceAutomatic 10/100BaseT detection
Power supply12–24 V DC, current consumption approximately 100 mA at 24 V
PoE – Power over Ethernet
Galvanic isolationOutputs relative to the network interface: min. 1000 V
Inputs relative to the network interface: min. 2000 V
Inputs versus outputs: min. 1000 V
Connectors and terminal blocks3 x 12x, 1 x 11x plug-in screw terminal blocks for inputs and outputs – plug-in
1 x 4x, plug-in screw terminal for power supply – plug-in
1 x RJ45 for network connection
SignallingStatus LEDs for the network
24 LEDs for displaying digital states
Protocols and servicesHTTP and HTTPS
TCP and UDP sockets, client and server
MQTT – Publishing and Subscribing
REST
SNMP V1, V2, V3, including traps
Sending emails via the SMTP protocol
OPC server
Modbus TCP
Inventory and device group management
Response timesData and switching operation: typically 20 ms
Housing and mountingPlastic housing for DIN rail mounting
90 × 116 × 56 mm (L × W × H)
Degree of protectionIP20
Weightapprox. 250 g
Storage temperature-25 to +70 °C
Operating temperature0 to +60 °C
Permissible relative humidity5 to 95 per cent RH, non-condensing
Contents of the delivery1 x Web-IO 4.0 Digital, 12 inputs, 8 relay outputs
1× quick start guide
The power supply and other accessories must be ordered separately

Signals, communication and events

  • The relay outputs consist of seven changeover contacts and one make contact. The contacts are rated for a maximum of 24 V AC/DC and 2 A; a suitable isolating relay is required for higher voltages. The outputs are not intended for direct switching of 230 V.
  • The web interface supports HTTP/HTTPS. OPC UA, MQTT Publish/Subscribe, REST and Modbus TCP are available for integration; individual services and the necessary permissions are configured on the device.
  • Up to 30 actions can be configured, such as an email, an SNMP trap, an output switch or an HTTP request. SNMP supports versions V1, V2 and V3.
  • Box-to-Box mode transfers switching states between suitably configured Web-IO devices over the network. Correct mapping of inputs and outputs is part of the configuration.
  • The inputs support 32-bit event counters. The parameters for input voltage, switching threshold and current consumption are governed by the table for this model.

Commissioning and accessories

Check the module’s power supply, common conductors, polarity and output loads. Once connected to the network, configure the IP address, access rights, required protocols and event responses. Before connecting the load, check the wiring in accordance with the manual for the specific model.

Contents of the delivery

  • 1 x Web-IO 4.0 Digital, 12 inputs, 8 relay outputs
  • 1× quick start guide
  • The power supply and other accessories must be ordered separately

Frequently Asked Questions

How many physical channels does this model have?

The relay outputs consist of seven changeover contacts and one make contact. The contacts are rated for a maximum of 24 V AC/DC and 2 A; a suitable isolating relay is required for higher voltages. The outputs are not intended for direct switching of 230 V.

Do I need a special programme to operate it?

A web interface is available for basic monitoring and control. A supported protocol and its access rights are configured for the host system.

Does ‘Box-to-Box’ refer to a fixed response time?

No. The typical response times shown in the table do not guarantee the overall response of the entire network. The result also depends on network communication and the configuration of both devices.

Why order from FOXON?

Before placing an order, we will check the current availability of the part and confirm the estimated delivery date. We will assist you in selecting the equipment and necessary accessories based on the wiring configuration and required communication. We will confirm the warranty terms and the scope of any diagnostics or repairs for the specific quotation.

More than 3,500customers
We supply tomore than 100 countries worldwide
Express delivery?We will look into this; please contact us immediately.

Documentation and technical consultancy

Technical data and documentation W&T 57738

Manuals, firmware and tools for this model can also be found in the Downloads tab. For service enquiries, please use sale and repair of FOXON industrial parts.

Do you need to select or order W&T 57738?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.

Enquire about purchasing or repairing a part

Diagrams and illustrations

W&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the productW&T 57738 – diagram or illustration of the product

Further related links

Technical specifications for W&T 57738

Digital outputs8× potential-free contacts, max. 24 V DC / 2 A or 24 V AC / 2 A
With suitable isolating relays, voltages of up to
230 V.
Digital inputs12× digital inputs
Maximum input voltage ±30 V
Reverse polarity protection within this range
Switching threshold 4 V ± 0.5 V
Current when switched on = 2.2 mA
Integrated 32-bit pulse counter
Network interfaceAutomatic 10/100BaseT detection
Power supply12–24 V DC, current consumption approximately 100 mA at 24 V
PoE – Power over Ethernet
Galvanic isolationOutputs relative to the network interface: min. 1000 V
Inputs relative to the network interface: min. 2000 V
Inputs versus outputs: min. 1000 V
Connectors and terminal blocks3 x 12x, 1 x 11x plug-in screw terminal blocks for inputs and outputs – plug-in
1 x 4x, plug-in screw terminal for power supply – plug-in
1 x RJ45 for network connection
SignallingStatus LEDs for the network
24 LEDs for displaying digital states
Protocols and servicesHTTP and HTTPS
TCP and UDP sockets, client and server
MQTT – Publishing and Subscribing
REST
SNMP V1, V2, V3, including traps
Sending emails via the SMTP protocol
OPC server
Modbus TCP
Inventory and device group management
Response timesData and switching operation: typically 20 ms
Housing and mountingPlastic housing for DIN rail mounting
90 × 116 × 56 mm (L × W × H)
Degree of protectionIP20
Weightapprox. 250 g
Storage temperature-25 to +70 °C
Operating temperature0 to +60 °C
Permissible relative humidity5 to 95 per cent RH, non-condensing
Contents of the delivery1 x Web-IO 4.0 Digital, 12 inputs, 8 relay outputs
1× quick start guide
The power supply and other accessories must be ordered separately