W&T 57120 Ethernet temperature and humidity sensor, OPC UA, MQTT
- Machine data collection
- OPC UA / MQTT Sensors
- W&T 57120 Ethernet temperature and humidity sensor, OPC UA, MQTT
W&T 57120 Ethernet temperature and humidity sensor, OPC UA, MQTT
The W&T 57120 is a networked measurement system with a separate probe for temperature and relative humidity. It offers web-based visualisation, internal data logging and connectivity via OPC UA, MQTT, REST and Modbus TCP. More
Code: 57120
The W&T 57120 is a networked measurement system with a separate probe for temperature and relative humidity. It offers web-based visualisation, internal data logging and connectivity via OPC UA, MQTT, REST and Modbus TCP. More
Code: 57120
Temperature and relative humidity via Ethernet
Price on request
The W&T 57120 is a networked measurement system with a separate probe for temperature and relative humidity. It offers web-based visualisation, internal data logging and connectivity via OPC UA, MQTT, REST and Modbus TCP.
Do you need to select or order the W&T 57120?
Please send us the required quantity and a description of the wiring configuration. We will confirm the price and availability in our quotation.
Usage
The combined probe measures temperature and relative humidity. In addition to direct readings, derived parameters are available, such as dew point, absolute humidity, mixing ratio and enthalpy.
Technical specifications for the W&T 57120
| Combined sensor | Temperature and relative humidity measurement DB9 socket Cable length: 2 m, can be extended to a maximum of 20 m |
|---|---|
| Network interface | 10/100BaseT, auto-detection / Auto-MDIX RJ45 IPv6 on request |
| Galvanic isolation | Network interface section: min. 1500 V |
| Supply voltage | Power-over-Ethernet (PoE) or 12–48 V DC (±10 %) |
| Power connection | Removable screw terminal block, pitch 5.08 mm Marked ‘L+’ and ‘M’ |
| Current consumption | PoE Class 1 (0.44–3.84 W) typ. 69 mA at 24 V DC max. 80 mA at 24 V DC |
| Signalling | 1 Power LED 2× network status LEDs 4 LEDs for status and faults |
| Measuring range | -40 °C to 85 °C, 0 to 100 per cent relative humidity |
| Resolution | 1/10 °C, 1/10 % rH |
| Quantities displayed | Temperature: °C, °F, K; relative humidity: % RH; absolute humidity: g/m³; dew point: °C; mixing ratio: g/kg; enthalpy: kJ/kg |
| Measurement error | Temperature: typ. at 25 °C ±0.3 °C max. @ -40 to 85 °C ±1.5 °C Relative humidity: typ. @ -20 to 60 °C (normal range) ±1.8 % rH (10–90 % rH) max. at -20 to 60 °C (normal range) ±4 % rH (0–100 % rH) Temporary humidity deviation: +3 % RH after 60 hours of operation outside the normal temperature range, between -40 and +85 °C Long-term stability: typically <0.5 % rH/year |
| Measurement period | 4s |
| Save interval | 15 s, 30 s, 1 min, 5 min, 15 min, 60 min |
| History capacity (4 MB memory) | min. 12 weeks, max. 20 years |
| Housing and mounting | Compact plastic housing for DIN rail mounting 105 × 22 × 75 mm (length × width × height) |
| Degree of protection | IP20 |
| Weight | approx. 200 g |
| Ambient temperature | Storage: -40 to +70 °C Operating temperature with spacing between devices: 0 to +60 °C Operating temperature when installed side by side without spacing: 0 to +50 °C |
| Permissible relative humidity | 0 to 95 per cent RH, non-condensing |
| Mean Time Between Failures (MTBF) | 931,372 hours at 25 °C in accordance with MIL-HDBK-217 |
| Contents of the delivery | 1x web-based thermo-hygrometer 1× W&T sensor, 2 m (temperature, relative humidity) 1× quick start guide |
Measured quantities and conditions of use
- The combined probe measures temperature and relative humidity. In addition to direct readings, derived parameters are available, such as dew point, absolute humidity, mixing ratio and enthalpy.
- The scope of supply includes a combined probe with a 2 m cable. W&T permits the probe connection to be extended to a maximum of 20 m for this model.
- Values are updated every 4 seconds. The history is stored at separate intervals: 15 or 30 seconds, or 1, 5, 15 or 60 minutes.
- Up to 12 configurable alerts enable notifications via email or SNMP. The network module and probe have their own operating conditions; the probe’s measurement range is not the same as the module’s operating temperature.
- A humidity measurement range of 0–100 % RH does not imply that condensation on the electronics is permitted. Permissible operating conditions are specified separately in the technical table.
Commissioning and accessories
Position the probe so that it measures the required area and is not affected by heat from surrounding equipment. Set the IP address, the displayed parameters, the logging interval and the alarm limits. If extending the cable, use suitable cabling and do not exceed a length of 20 m.
Contents of the delivery
- 1x web-based thermo-hygrometer
- 1× W&T sensor, 2 m (temperature, relative humidity)
- 1× quick start guide
Frequently Asked Questions
Can I extend the probe cable?
Yes. This model comes with a 2-metre cable, which can be extended to a maximum of 20 metres. Use cabling that complies with the manufacturer’s wiring specifications.
Does the temperature measurement range also apply to the network module?
No. The measurement range applies to the probe. The module itself has its own specified operating temperature and installation conditions.
What does the stated typical accuracy mean?
Applies under the conditions specified for the particular quantity and range in the table. When assessing these, it is necessary to distinguish between temperature, relative humidity and, where applicable, pressure, as well as long-term stability.
Why order from FOXON?
Before placing an order, we will check the current availability of the part and confirm the estimated delivery date. We will assist you in selecting the equipment and necessary accessories based on the wiring configuration and required communication. We will confirm the warranty terms and the scope of any diagnostics or repairs for the specific quotation.
Documentation and technical consultancy
Technical data and documentation for W&T 57120
Manuals, firmware and tools for this model can also be found in the Downloads tab. For service enquiries, please use sale and repair of FOXON industrial parts.
Do you need to select or order the W&T 57120?
Please send us the required quantity and a description of the wiring configuration. We will confirm the price and availability in our quotation.
Technical specifications of the W&T 57120
| Combined sensor | Temperature and relative humidity measurement DB9 socket Cable length: 2 m, can be extended to a maximum of 20 m |
|---|---|
| Network interface | 10/100BaseT, auto-detection / Auto-MDIX RJ45 IPv6 on request |
| Galvanic isolation | Network interface section: min. 1500 V |
| Supply voltage | Power-over-Ethernet (PoE) or 12–48 V DC (±10 %) |
| Power connection | Removable screw terminal block, pitch 5.08 mm Marked ‘L+’ and ‘M’ |
| Current consumption | PoE Class 1 (0.44–3.84 W) typ. 69 mA at 24 V DC max. 80 mA at 24 V DC |
| Signalling | 1 Power LED 2× network status LEDs 4 LEDs for status and faults |
| Measuring range | -40 °C to 85 °C, 0 to 100 per cent relative humidity |
| Resolution | 1/10 °C, 1/10 % rH |
| Quantities displayed | Temperature: °C, °F, K; relative humidity: % RH; absolute humidity: g/m³; dew point: °C; mixing ratio: g/kg; enthalpy: kJ/kg |
| Measurement error | Temperature: typ. at 25 °C ±0.3 °C max. @ -40 to 85 °C ±1.5 °C Relative humidity: typ. @ -20 to 60 °C (normal range) ±1.8 % rH (10–90 % rH) max. at -20 to 60 °C (normal range) ±4 % rH (0–100 % rH) Temporary humidity deviation: +3 % RH after 60 hours of operation outside the normal temperature range, between -40 and +85 °C Long-term stability: typically <0.5 % rH/year |
| Measurement period | 4s |
| Save interval | 15 s, 30 s, 1 min, 5 min, 15 min, 60 min |
| History capacity (4 MB memory) | min. 12 weeks, max. 20 years |
| Housing and mounting | Compact plastic housing for DIN rail mounting 105 × 22 × 75 mm (length × width × height) |
| Degree of protection | IP20 |
| Weight | approx. 200 g |
| Ambient temperature | Storage: -40 to +70 °C Operating temperature with spacing between devices: 0 to +60 °C Operating temperature when installed side by side without spacing: 0 to +50 °C |
| Permissible relative humidity | 0 to 95 per cent RH, non-condensing |
| Mean Time Between Failures (MTBF) | 931,372 hours at 25 °C in accordance with MIL-HDBK-217 |
| Contents of the delivery | 1x web-based thermo-hygrometer 1× W&T sensor, 2 m (temperature, relative humidity) 1× quick start guide |