INS-8405EM - VOLKTEK unmanaged marine switch, 5× RJ45
- Switches and Wi-Fi
- DNV / LR Marine Switches
- INS-8405EM - VOLKTEK unmanaged marine switch, 5× RJ45
INS-8405EM - VOLKTEK unmanaged marine switch, 5× RJ45
Ethernet for marine and offshore networks
Unmanaged marine switch. 5× RJ45 / 10/100/1000 Mbit/s. Connects PLCs, HMIs and other Ethernet devices in marine automation. Metal DIN-rail design with documented marine approval and separate conditions for installation under DNV.
DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval.
The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions.

We’ll select a switch for your industrial network
We can help you choose the right model and power supply. We will confirm the price, current stock availability and delivery date.
Marine approval and operating conditions
DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval.
LR: environmental categories ENV1, ENV2 and ENV3.
The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions.
Assess the approval scope for the exact order code and installation. We will check the required documentation and requirements for environment, power and cabinet placement.
Technical specifications
| Order code | VOLKTEK INS-8405EM |
|---|---|
| Design | Unmanaged marine switch |
| Copper ports | 5× RJ45 / 10/100/1000 Mbit/s |
| SFP slots | No optical ports |
| Switching capacity | 10 Gbit/s |
| MAC address table | 2K |
| Maximum frame length | 9216 Bytes |
| Power inputs | 1 input / 12-48 V DC |
| Power consumption | 4 W |
| Housing | IP40 |
| Marine approval | DNV; LR ENV1 / ENV2 / ENV3 |
| DNV Class D conditions | -25…+70 °C / 24 V DC |
| Protection under DNV Type Approval | IP20 |
| General device operating temperature | -40…+75 °C |
| Dimensions (W × H × D) | 23.6 × 109.2 × 73.8 mm |
| Weight | 183.4 g |
| Mounting | DIN rail |
| Traffic priority | Port 1, IEEE 802.1p QoS, iQoS |
Unmanaged Premium: traffic priority
The device operates without web management or a switch IP address setting. Once power and Ethernet cables are connected, it interconnects the end devices. Set PLC, HMI and other device addresses on those devices.
Supports Flow Control, Storm Control, VLAN Passthrough and port 1 priority. IEEE 802.1p QoS and iQoS prioritise EtherNet/IP, PROFINET and GOOSE traffic. Passing VLAN tags does not replace VLAN configuration on a managed switch.
Power supply and alarm
1× 12-48 V DC. One power input. For DNV marine installation, use nominal 24 V DC. Check wiring and polarity against the installation guide and device label.
Interfaces and mounting




Install in a suitable cabinet or protective enclosure. Provide grounding, free airflow and access to connectors. Neither IP30 nor IP40 provides protection against water. Wire with power disconnected and follow the installation guide.
Package contents
- 1× VOLKTEK INS-8405EM
- 1× DIN-rail mounting kit
- 1× Quick installation guide
Select the power supply separately. For SFP versions, select optical modules according to fibre, speed, distance and temperature conditions.
Downloads
Original VOLKTEK documentation in English. Files are also available in the Downloads tab.
VOLKTEK videos
Official introduction to marine switches and their applications. Videos are in English.
Frequently asked questions
Which conditions apply to marine approval?
DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval. The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions. LR: environmental categories ENV1, ENV2 and ENV3.
Does the switch require configuration?
The device operates without web management or a switch IP address setting. Once power and Ethernet cables are connected, it interconnects the end devices. Set PLC, HMI and other device addresses on those devices.
Which power supply should I use?
1× 12-48 V DC. One power input. For DNV marine installation, use nominal 24 V DC. Check wiring and polarity against the installation guide and device label.
How should I mount the switch?
Install in a suitable cabinet or protective enclosure. Provide grounding, free airflow and access to connectors. Neither IP30 nor IP40 provides protection against water. Wire with power disconnected and follow the installation guide.
Does this model have optical ports?
This model has copper RJ45 ports only. If you need fibre between remote cabinets, we will help select a suitable model with SFP slots.
Can you help with selection and availability?
We supply new original VOLKTEK products with warranty. We will discuss port count and speed, power supply and marine requirements, then confirm the price, current availability and delivery time before ordering.
Why buy from FOXON?
We are a VOLKTEK distributor. We supply new, genuine products and assist with their selection and use in industrial networks.
New products with a warranty
We supply the INS-8405EM as a new, genuine VOLKTEK switch with a warranty and manufacturer documentation.
Technical support
We can advise you on selecting a switch, power supply and accessories. We will discuss the wiring and requirements of your application.
Stock availability and delivery
We will check current stock availability and confirm the price and estimated delivery date before you place your order.
Pre-purchase consultation
We help select a model based on device count, transfer speed, power supply and operating conditions. We will discuss network management, VLAN and traffic monitoring requirements.
Enquiry and technical consultation
New original product with warranty. Availability and delivery time confirmed on enquiry.
Assess the approval scope for the exact order code and installation. We will check the required documentation and requirements for environment, power and cabinet placement.
We’ll select a switch for your industrial network
We can help you choose the right model and power supply. We will confirm the price, current stock availability and delivery date.
Technical specifications
| Order code | VOLKTEK INS-8405EM |
|---|---|
| Design | Unmanaged marine switch |
| Copper ports | 5× RJ45 / 10/100/1000 Mbit/s |
| SFP slots | No optical ports |
| Switching capacity | 10 Gbit/s |
| MAC address table | 2K |
| Maximum frame length | 9216 Bytes |
| Power inputs | 1 input / 12-48 V DC |
| Power consumption | 4 W |
| Housing | IP40 |
| Marine approval | DNV; LR ENV1 / ENV2 / ENV3 |
| DNV Class D conditions | -25…+70 °C / 24 V DC |
| Protection under DNV Type Approval | IP20 |
| General device operating temperature | -40…+75 °C |
| Dimensions (W × H × D) | 23.6 × 109.2 × 73.8 mm |
| Weight | 183.4 g |
| Mounting | DIN rail |
| Traffic priority | Port 1, IEEE 802.1p QoS, iQoS |
Marine approval and operating conditions
DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval.
The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions.
Frequently asked questions
Which conditions apply to marine approval?
DNV Class D: -25 to +70 °C at nominal 24 V DC. The general operating range of -40 to +75 °C does not extend the scope of marine approval. The device has an IP40 housing. DNV Type Approval for this model specifies IP20; design the marine installation according to the approval conditions. LR: environmental categories ENV1, ENV2 and ENV3.
Does the switch require configuration?
The device operates without web management or a switch IP address setting. Once power and Ethernet cables are connected, it interconnects the end devices. Set PLC, HMI and other device addresses on those devices.
Which power supply should I use?
1× 12-48 V DC. One power input. For DNV marine installation, use nominal 24 V DC. Check wiring and polarity against the installation guide and device label.
How should I mount the switch?
Install in a suitable cabinet or protective enclosure. Provide grounding, free airflow and access to connectors. Neither IP30 nor IP40 provides protection against water. Wire with power disconnected and follow the installation guide.
Does this model have optical ports?
This model has copper RJ45 ports only. If you need fibre between remote cabinets, we will help select a suitable model with SFP slots.
Can you help with selection and availability?
We supply new original VOLKTEK products with warranty. We will discuss port count and speed, power supply and marine requirements, then confirm the price, current availability and delivery time before ordering.