IEN-9648-SS - VOLKTEK Industrial managed switch

IEN-9648-SS - VOLKTEK Industrial managed switch


VOLKTEK

VOLKTEK IEN-9648-SS: 8× RJ45 / 10/100/1000 Mbit/s; 4× SFP / 1G. Managed. 12-48 V DC; IP30; -40…+75 °C. More

Code: IEN-9648-SS

Rezervace termínu

Get a quote
VOLKTEK

VOLKTEK IEN-9648-SS: 8× RJ45 / 10/100/1000 Mbit/s; 4× SFP / 1G. Managed. 12-48 V DC; IP30; -40…+75 °C. More

Code: IEN-9648-SS

VOLKTEK IEN-9648-SS

Industrial managed switch

Connects Ethernet devices in an industrial network. Copper ports connect endpoints; fibre slots allow links between cabinets or to an upstream network.

8× RJ45 / 10/100/1000 Mbit/s4× SFP / 1GManaged12-48 V DC

DIP switch configuration: PWR / RPS

VOLKTEK IEN-9648-SS - Overall device view
Overall device view. Click to enlarge the image.

We will select a switch for your network
We will review endpoints, ports and power, then confirm price, current availability and delivery time for a new product.

Enquire about a VOLKTEK solution
IEC 61850-3 / IEEE 1613Applications and approval conditions
Managed12-48 V DC
-40…+75 °CIP30 / DIN rail

Applications and device connections

For connecting PLCs, HMIs, industrial PCs and other Ethernet devices. Design topology, speeds and fibre modules around distances, communication availability requirements and installation conditions.

Management and Monitoring

Configure network functions and monitoring through switch management. During commissioning, set addressing and access credentials, configure ports and save the configuration.

CLI / SNMP / IEEE 802.1Q VLAN / QoS / IGMP Snooping / RSTP / MSTP / LACP / LLDP / Xpress Ring / SSH / Syslog / ERPS / IEEE 1588v2 PTP

Power supply and alarm

12-48 V DC. Two power inputs allow connection of primary and redundant supplies. A separate backed-up supply is needed to bridge simultaneous failure of both sources. Follow input voltage, polarity and specified wiring. Select the supply for switch consumption, endpoint power and operating reserve.

DIP switch configuration

Enable or disable PWR / RPS input monitoring.

Set switch positions according to device labels and the supplied installation guide.

Applications and approval conditions

IEC 61850-3 / IEEE 1613

For industrial communication in substations and power facilities requiring IEC 61850-3 and IEEE 1613. Approval concerns switch operating conditions; verify endpoint protocols and functions separately.

UL-approved temperature range: -40…70 °C

Technical specifications

Order codeVOLKTEK IEN-9648-SS
ManagementManaged
Data interface8× RJ45 / 10/100/1000 Mbit/s
Optical interface4× SFP / 1G
Power supply12-48 V DC
Power consumption18 W
Network functionsCLI / SNMP / IEEE 802.1Q VLAN / QoS / IGMP Snooping / RSTP / MSTP / LACP / LLDP / Xpress Ring / SSH / Syslog / ERPS / IEEE 1588v2 PTP
Console / USB1× RS-232 (RJ45) / 1× USB
Relay alarm1 A / 24 V DC
DIPEnable or disable PWR / RPS input monitoring.
Protection ratingIP30
MountingDIN rail
Operating temperature-40…+75 °C
UL-approved temperature range-40…70 °C
Approvals and application standardsIEC 61850-3 / IEEE 1613
Dimensions (W × H × D)50 × 161.5 × 119.9 mm
Weight955 g

Interfaces and mounting

Select the SFP module separately. It must match the slot speed, fibre type, connector, wavelength and remote device. Reach depends on the selected optics and link attenuation.

VOLKTEK IEN-9648-SS - Interface diagram
Interface diagram. Original manufacturer diagram with English labels. Click to enlarge the image.
VOLKTEK IEN-9648-SS - Dimensional drawing
Dimensional drawing. Click to enlarge the image.

Install in a suitable cabinet or protective enclosure. Provide grounding, free airflow and access to connectors. Neither IP30 nor IP40 provides protection against water. Wire with power disconnected and follow the installation guide.

Package contents

The standard set contains the switch and mounting accessories for the selected version. Power supply, fibre modules and data cabling are selected separately. We will confirm the complete delivery contents in the quotation.

Downloads

Original VOLKTEK documentation in English. Files are also available in the Downloads tab.

VOLKTEK IEN-9648-SS - Datasheet (EN)VOLKTEK / ENOpen PDF
VOLKTEK IEN-9648-SS - Quick installation guide (EN)VOLKTEK / ENOpen PDF
VOLKTEK IEN-9648-SS - User manual (EN)VOLKTEK / ENOpen PDF

VOLKTEK videos

Official VOLKTEK video about the technology or product range. The video is in English; see the table and documents above for exact model specifications.

VOLKTEK technology and solutions

Frequently asked questions

Does this switch support management?

Managed. Configure network functions and monitoring through switch management. During commissioning, set addressing and access credentials, configure ports and save the configuration.

Which power supply do I need?

12-48 V DC. Two power inputs allow connection of primary and redundant supplies. A separate backed-up supply is needed to bridge simultaneous failure of both sources. Follow input voltage, polarity and specified wiring. Select the supply for switch consumption, endpoint power and operating reserve.

What do the DIP switches configure?

Enable or disable PWR / RPS input monitoring. Set switch positions according to device labels and the supplied installation guide.

How do I select the right optics?

4× SFP / 1G. Select the SFP module separately. It must match the slot speed, fibre type, connector, wavelength and remote device. Reach depends on the selected optics and link attenuation.

Applications and approval conditions

For industrial communication in substations and power facilities requiring IEC 61850-3 and IEEE 1613. Approval concerns switch operating conditions; verify endpoint protocols and functions separately.

Will you check model suitability and availability?

We supply new original VOLKTEK products with warranty. We help select the switch, supply, optics and accessories. Before ordering, we check price, current stock availability and delivery time.

Why buy from FOXON

We are a VOLKTEK distributor. We supply new original products with warranty and technical support.

New products with warranty

New original product with warranty. Availability and delivery time confirmed on enquiry.

Technical support

We advise on interfaces, optics, power and accessories for your application.

Availability and delivery

We will check current availability, price and possible delivery time before ordering.

Pre-purchase consultation

We will review endpoints, ports and power, then confirm price, current availability and delivery time for a new product.

More than 3,500customers
We supply tomore than 100 countries worldwide
Express delivery?We’ll look into it; please contact us immediately.

Enquiry and technical consultation

Send the quantity, connected devices, power supply, cable type and link distance. We will help select a suitable version and prepare a quotation.

We will select a switch for your network
We will review endpoints, ports and power, then confirm price, current availability and delivery time for a new product.

Enquire about a VOLKTEK solution

Technical specifications

Order codeVOLKTEK IEN-9648-SS
ManagementManaged
Data interface8× RJ45 / 10/100/1000 Mbit/s
Optical interface4× SFP / 1G
Power supply12-48 V DC
Power consumption18 W
Network functionsCLI / SNMP / IEEE 802.1Q VLAN / QoS / IGMP Snooping / RSTP / MSTP / LACP / LLDP / Xpress Ring / SSH / Syslog / ERPS / IEEE 1588v2 PTP
Console / USB1× RS-232 (RJ45) / 1× USB
Relay alarm1 A / 24 V DC
DIPEnable or disable PWR / RPS input monitoring.
Protection ratingIP30
MountingDIN rail
Operating temperature-40…+75 °C
UL-approved temperature range-40…70 °C
Approvals and application standardsIEC 61850-3 / IEEE 1613
Dimensions (W × H × D)50 × 161.5 × 119.9 mm
Weight955 g

DIP switch configuration

Enable or disable PWR / RPS input monitoring.

Set switch positions according to device labels and the supplied installation guide.

Applications and approval conditions

IEC 61850-3 / IEEE 1613

For industrial communication in substations and power facilities requiring IEC 61850-3 and IEEE 1613. Approval concerns switch operating conditions; verify endpoint protocols and functions separately.

UL-approved temperature range: -40…70 °C

Frequently asked questions

Does this switch support management?

Managed. Configure network functions and monitoring through switch management. During commissioning, set addressing and access credentials, configure ports and save the configuration.

Which power supply do I need?

12-48 V DC. Two power inputs allow connection of primary and redundant supplies. A separate backed-up supply is needed to bridge simultaneous failure of both sources. Follow input voltage, polarity and specified wiring. Select the supply for switch consumption, endpoint power and operating reserve.

What do the DIP switches configure?

Enable or disable PWR / RPS input monitoring. Set switch positions according to device labels and the supplied installation guide.

How do I select the right optics?

4× SFP / 1G. Select the SFP module separately. It must match the slot speed, fibre type, connector, wavelength and remote device. Reach depends on the selected optics and link attenuation.

Applications and approval conditions

For industrial communication in substations and power facilities requiring IEC 61850-3 and IEEE 1613. Approval concerns switch operating conditions; verify endpoint protocols and functions separately.

Will you check model suitability and availability?

We supply new original VOLKTEK products with warranty. We help select the switch, supply, optics and accessories. Before ordering, we check price, current stock availability and delivery time.