RailBox

RailBox


ACKSYS

ACKSYS RailBox V2 is a range of rugged industrial routers for railway applications. Depending on the order code, it offers Wi-Fi 5/6/6E, LTE or 5G, 2× 2.5 Gigabit Ethernet M12 and IP66 protection. The radio configuration, power supply, GNSS and any Ethernet bypass must be selected for the specific application. More

Code: RailBox

Recycling fee 0,04 EUR included in the price.
0 pcs In stock

Rezervace termínu

Get a quote
ACKSYS

ACKSYS RailBox V2 is a range of rugged industrial routers for railway applications. Depending on the order code, it offers Wi-Fi 5/6/6E, LTE or 5G, 2× 2.5 Gigabit Ethernet M12 and IP66 protection. The radio configuration, power supply, GNSS and any Ethernet bypass must be selected for the specific application. More

Code: RailBox

ACKSYS | RailBox v2 - overview of variants

ACKSYS RailBox V2 - industrial communications for the railway

RailBox V2 is a range of robust routers for on-board networks and vehicle-to-infrastructure communication. Depending on the order code, it combines Wi-Fi, LTE or 5G with two M12 Ethernet ports offering speeds of up to 2.5 Gbit/s per port. The specific radio interface, power supply and optional features are selected according to the application.

ACKSYS RailBox V2 - overview of variants

Selecting devices and accessories
Please send us a description of the application, the number of devices and your communication requirements. We will recommend suitable models and accessories.

Enquire about equipment and a consultation
Wi-Fi / LTE / 5GRadio by order code
2 × 2.5 Gigabit EthernetRobust M12 X-coded connectors
IP66Railway version EN50155

Usage

RailBox V2 is used for on-board Wi-Fi, CCTV and information systems, data transmission between the train and the infrastructure, and the interconnection of carriages. Its IP66 rating and railway-grade design enable deployment in environments subject to vibration and harsh climatic conditions.

Radio variants

The range includes WiFi 5, WiFi 6 and WiFi 6E variants, as well as models with LTE Cat. 12 or 5G. WiFi 6E is currently intended for Access Point mode; support for other functions must be verified for the specific model and firmware. The maximum radio speed does not represent the throughput of the entire application.

Power supply and Ethernet bypass selection

The 24-110 VDC power supply version with isolated redundant inputs and the PoE-powered version are different variants. The PoE version cannot be powered automatically via an external DC cable. The Ethernet bypass is optional, and we will verify its combination with the power supply based on the full order code.

GNSS and mobile network

LTE and 5G interfaces are not included in every RailBox. The /xS variant uses LTE Cat. 12 and an active GNSS antenna. 5G variants /xU and /xV also differ in their requirement for a passive or active GNSS antenna. When designing the system, it is necessary to specify the mobile bands, antennas and the full device code.

Replacement of an older RailBox

When requesting a replacement, please provide the full order code, a photograph of the label, the power supply and the required radio functions. The product lifecycle is assessed on a variant-by-variant basis. Older generations and certain V2 variants have already had their end-of-life or end-of-support dates announced; the name RailBox alone is not sufficient to select a replacement.

Contents of the package

RailBox V2 is ordered in a specific radio and power supply configuration. A mounting plate is included; antennas and connection cables must be selected according to the specific variant. The term RailBox on this page refers to a range of devices, not a single universal configuration.

WaveOS and centralised management

Configuration and diagnostics are carried out via the interface supported by the specific model. WaveManager is available as an on-premises or cloud solution; the licence, number of managed devices and required features are selected according to the installation. Before updating the firmware, save the configuration and verify compatibility. The EN 18031 security updates remove weak encryption and authentication methods; it is therefore necessary to check the network settings in advance.

Design guidelines

For a fixed link, provide the distance, obstacles, required throughput and antenna locations. For AGVs and mobile machinery, include the route, existing access points and required response time. For a mobile router, please specify the network operator, the bands used, the power supply and any GNSS requirements.

Selection and technical consultation at FOXON

We can help you select the model, power supply, antennas and cabling to suit your specific equipment and environment. When designing a Wi-Fi connection, we need to know the distance, any obstacles, the movement of devices and the application requirements. We will confirm current availability and the delivery date in our quotation.

Frequently Asked Questions

Actual data transfer rate

The radio speed specified for Wi-Fi does not represent the actual application throughput. The result is affected by interference, channel width, antennas, distance, obstacles and traffic from other devices. Please provide the required throughput and a description of the environment for a proposal.

Transmission of industrial protocols

WiFi devices transmit Ethernet communication. They do not replace a PLC or a protocol converter. For PROFINET, EtherNet/IP and other time-sensitive applications, it is necessary to verify the topology, cycle time and behaviour during roaming.

Antennas and cables

Connector types and the number of antennas vary by model. Before ordering, please check the full router model number, Ethernet ports, power supply and installation requirements. The contents of the package are listed separately.

Documentation and related materials

Technical documents are in the language specified. A Czech or other translated file name does not imply that the PDF itself has been translated.

Further documentation and current manufacturer’s materials from ACKSYS

Archived documentation

Older documentation is intended for the corresponding generation of devices and firmware. Do not use it to determine the specifications of the current version.

RailBox historical ordering scheme

The historical diagram relates to an older RailBox range; do not use it to generate V2 order codes.

RailBox historical ordering scheme

Quotation for a specific installation
Please send us a description of the application, the number of devices and your communication requirements. We will recommend suitable models and accessories.

Enquire about equipment and a consultation

Technical specifications

SecurityFirewall, DoS, HTTPS, MAC address filtering, WPA/WPA2/WPA3-Personal & Enterprise (IEEE 802.1X/RADIUS), L2 tunnels (GRE), VPN (OpenVPN, IPsec), SNMP v3, unauthorised access point detector, file system integrity monitor, strong password policies, management of open ports and services
Wi-FiWi-Fi 5, Wi-Fi 6 or Wi-Fi 6E, depending on the radio configuration ordered. The maximum radio data rates must be specified for each variant.
Network functionsFrame filtering, bridging, repeater, STP/RSTP, VLAN, DHCP (server and client), DNS relay, IPv6 compatible, LLDP
RoutingMulticast (PIM), IP redundancy (VRRP), static routes, NAT router, router, vehicle coupling system (SRCC)
AdministrationMQTT, http, https, SNMP agent (V1, V2C, V3), WaveManager administration software, saving/restoring the configuration key (C-Key)
Digital I/O3-pin waterproof M8 connector with: - one output for warning via a solid-state relay (with configurable action), 1 form A, max. 60 V DC, 80 mA - one input for controlling an external device, max. 24 V DC
Dimensions and weightCompact, shock-resistant and durable aluminium housing (L: 80 x W: 175 x H: 57 mm), 900 g Removable mounting plate: 4-point mounting plate with earthing lug (L: 80 x W: 225 x H: 4 mm), 200 g
EnvironmentOperating: -25 °C to +70 °C (relative humidity 0-99%) Extended range: -40 °C to +70 °C / +85 °C for 10 minutes, TX class in accordance with EN 50155 Storage: -40 °C to +80 °C IP66 protection rating, GORE® protective valve (dehumidifying membrane)
Ethernet2 x 100/1000/2500 Mbit/s, M12 s with X encoding; optional Ethernet bypass depending on the variant ordered
Antenna connectorsQMA; the number and layout depend on the Wi-Fi, LTE or 5G configuration. Antennas are not included.
Operating modesAccess point, client, router, Mesh; available functions depend on the configuration of the radio module and firmware. Wi-Fi 6E is currently only supported in AP mode.
Power supplyDepending on the version: isolated redundant input 24 to 110 VDC or a special version powered via PoE. Please check the full order code before selecting a power supply.
Power consumptionDepends on the radio module configuration; the RailBox V2 series data sheet specifies a typical power consumption of 26 W and a maximum power consumption of 30 W for a configuration with two radio modules.

The table describes the RailBox V2 series. The parameters of the selected complete order code are decisive; not all functions are included in every variant.

Accessories3