- SIEMENS 6XV1830-0EU10 - Standard PROFIBUS DP cable for permanent installation
SIEMENS 6XV1830-0EU10 - Standard PROFIBUS DP cable for permanent installation
SIEMENS 6XV1830-0EU10 - standard PROFIBUS DP cable for fixed installation, 2-core, PVC, double-shielded, FastConnect, 8 mm diameter. Sold by the metre, minimum order 10 m. More
Code: 6XV1830-0EU10
SIEMENS 6XV1830-0EU10 - standard PROFIBUS DP cable for fixed installation, 2-core, PVC, double-shielded, FastConnect, 8 mm diameter. Sold by the metre, minimum order 10 m. More
Code: 6XV1830-0EU10
Standard PROFIBUS DP cable for permanent installation
FastConnect · PVC · fixed cabling
The SIEMENS 6XV1830-0EU10 PROFIBUS FC Standard Cable GP is a shielded two-core cable for permanent installation in PROFIBUS DP networks. The FastConnect design simplifies the preparation of cable ends for connector fitting. The purple PVC sheath and the red and green conductors correspond to standard PROFIBUS cabling.
Send the required length and installation method. We will check the suitable cable version and connectors.
Use during the installation and maintenance of the network
The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.
Sold by the metre, in lengths of 10 metres or more
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
The Siemens order number refers to a version with a length of 1,000 m. FOXON dispenses this cable by the metre; the quantity ordered via the online shop is expressed in metres.
Cable construction and double shielding
The cable has 2 conductors with an inner conductor diameter of 0.65 mm. Shielding consists of overlapping aluminium-coated foil and a tinned copper braid. Both the inner and outer sheaths are PVC. The cable is not halogen-free.

Bend radius and operating conditions
The minimum permissible bending radius is 37.5 mm for a single bend and 75 mm for repeated bending. The maximum tensile force is 100 N. The operating temperature range is -40 to +75 °C. When laying the cable, do not crush it, break it or damage the screening.
Oil resistance is defined by the IEC 60811-2-1 test: 4 hours at 70 °C. Resistance to water and fats is subject to conditions; please verify suitability for continuous exposure to a specific medium.
Cable end preparation and connector assembly
This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.
When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.
Cable length and segment termination
The length of each segment is determined by the transmission speed, cable specifications, connectors and topology. A 1,000-metre reel does not mean that this length can be used at any speed. To extend the network and divide it into further electrical segments, select a suitable repeater or ProfiHub.
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.
Technical specifications for 6XV1830-0EU10
| Manufacturer | SIEMENS |
|---|---|
| Order number | 6XV1830-0EU10 |
| Model designation | PROFIBUS FC Standard Cable GP |
| Uses | Fixed PROFIBUS DP installation |
| Number of cores / pairs | 2 wires / 1 pair |
| Wires | Copper, inner conductor diameter 0.65 mm |
| Wire colours | Red / green |
| Outer diameter | 8 mm ±0.4 mm |
| Outer sheath | PVC, purple |
| Shielding | Aluminium foil and tinned copper braiding |
| Halogen-free | No |
| FastConnect | Yes |
| Nominal impedance | 150 Ω in the 3-20 MHz band |
| Capacitance | 28.5 pF/m at 1 kHz |
| Loop resistance, maximum | 110 mΩ/m |
| Attenuation at 4 MHz, maximum | 2.2 dB per 100 metres |
| Attenuation at 16 MHz, maximum | 4.2 dB / 100 m |
| Minimum bend radius | 37.5 mm for a single bend; 75 mm for repeated bending |
| Operating temperature | -40 to +75 °C |
| Maximum tensile force | 100 N |
| Mass per unit length | 78 kg/km |
| Flame resistance | IEC 60332-3-24, Category C |
| Sales unit | Metre |
| FOXON minimum order quantity | 10 m |
Selection and correct use
Is this cable intended for use in a power chain?
The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.
How do I order the required length?
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
Is the cable halogen-free?
The cable has 2 conductors with an inner conductor diameter of 0.65 mm. Shielding consists of overlapping aluminium-coated foil and a tinned copper braid. Both the inner and outer sheaths are PVC. The cable is not halogen-free.
What bending radius should be used?
The minimum permissible bending radius is 37.5 mm for a single bend and 75 mm for repeated bending. The maximum tensile force is 100 N. The operating temperature range is -40 to +75 °C. When laying the cable, do not crush it, break it or damage the screening.
Can the FastConnect stripping tool be used?
This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.
Why order from FOXON
We can help you select the cabling and accessories to suit your specific PROFIBUS installation. Please send us a layout diagram, a list of device designations and a description of the environment.
Selection for a specific route
We will review the cable routing, movement, temperature and requirements of the installation.
Cable and connectors
We will check the compatibility of the conductors, the shielding, the dimensions and the method of installation.
Preparing the cabling
We’ll help you choose the right tool and procedure for your specific connector.
PROFIBUS Diagnostics
We can help with signal measurement, termination and identifying the causes of communication failures.
Czech technical support
We will discuss the topology, environment and cable replacement procedure with regard to the machine operating conditions.
Delivery Confirmation
Before placing an order, we will confirm the specifications, quantity and delivery date.
Technical data sheets and installation documentation
In the ‘Downloads’ tab, you will find the current technical data sheet for the exact order number 6XV1830-0EU10. Technical data sheets are available in EN, DE and ES, along with the PROFIBUS connector handbook and the Siemens cabling selection guide.
Open downloadsTechnical specifications 6XV1830-0EU10
PROFIBUS FC Standard Cable GP
Identification and design
| Manufacturer | SIEMENS |
|---|---|
| Order number | 6XV1830-0EU10 |
| Model designation | PROFIBUS FC Standard Cable GP |
| Uses | Fixed PROFIBUS DP installation |
| Number of cores / pairs | 2 wires / 1 pair |
| Wires | Copper, inner conductor diameter 0.65 mm |
| Wire colours | Red / green |
| Outer diameter | 8 mm ±0.4 mm |
| Outer sheath | PVC, purple |
| Shielding | Aluminium foil and tinned copper braiding |
| Halogen-free | No |
| FastConnect | Yes |
Electrical specifications
| Nominal impedance | 150 Ω in the 3-20 MHz band |
|---|---|
| Capacitance | 28.5 pF/m at 1 kHz |
| Loop resistance, maximum | 110 mΩ/m |
| Attenuation at 4 MHz, maximum | 2.2 dB per 100 metres |
| Attenuation at 16 MHz, maximum | 4.2 dB / 100 m |
Mechanical and operational data
| Minimum bend radius | 37.5 mm for a single bend; 75 mm for repeated bending |
|---|---|
| Operating temperature | -40 to +75 °C |
| Maximum tensile force | 100 N |
| Mass per unit length | 78 kg/km |
| Flame resistance | IEC 60332-3-24, Category C |
| Sales unit | Metre |
| FOXON minimum order quantity | 10 m |
Compatibility and preparation
This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.
When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.
Use and delivery
The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
Choosing the right model
Is this cable intended for use in a power chain?
The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.
How do I order the required length?
We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.
Is the cable halogen-free?
The cable has 2 conductors with an inner conductor diameter of 0.65 mm. Shielding consists of overlapping aluminium-coated foil and a tinned copper braid. Both the inner and outer sheaths are PVC. The cable is not halogen-free.
Installation and use
What bending radius should be used?
The minimum permissible bending radius is 37.5 mm for a single bend and 75 mm for repeated bending. The maximum tensile force is 100 N. The operating temperature range is -40 to +75 °C. When laying the cable, do not crush it, break it or damage the screening.
Can the FastConnect stripping tool be used?
This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.
How long can a single segment be?
The length of each segment is determined by the transmission speed, cable specifications, connectors and topology. A 1,000-metre reel does not mean that this length can be used at any speed. To extend the network and divide it into further electrical segments, select a suitable repeater or ProfiHub.
How do you connect the red and green wires?
When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.
Operations and technical consultancy
How do you terminate a PROFIBUS segment?
A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.
Is 150 Ω the value of the terminating resistor?
No. 150 Ω is the nominal characteristic impedance of the cable within the specified frequency band. The PROFIBUS terminator is a powered resistor network as specified in the interface design. Do not replace it with a single 150 Ω resistor.
Will a new cable sort out all the network outages?
A new cable will help if the existing cable is damaged or unsuitable. However, reliable communication requires the correct connectors, powered terminations, shielding and topology. Check the cause of any outages by measuring the entire route.

PROFIBUS: 3 Sins and 10 Tips
The PROFIBUS industrial bus is highly tolerant and will forgive many faults. But if a critical fault occurs—or several small ones accumulate—you will definitely notice. That’s why this aging industrial network deserves attention. Even if faults on your network are still rare, they will gradually accumulate. What do our technicians recommend? What are their 10 tips for maintaining PROFIBUS?
Highlighted items are mandatory.