SIEMENS 6XV1830-0EU10 - Standard PROFIBUS DP cable for permanent installation

SIEMENS 6XV1830-0EU10 - Standard PROFIBUS DP cable for permanent installation


SIEMENS

SIEMENS 6XV1830-0EU10 - standard PROFIBUS DP cable for fixed installation, 2-core, PVC, double-shielded, FastConnect, 8 mm diameter. Sold by the metre, minimum order 10 m. More

Code: 6XV1830-0EU10

2 EUR excl. VAT (2,42 EUR Incl. VAT)
In stock
m
(971 m In stock)

Rezervace termínu

Get a quote
SIEMENS

SIEMENS 6XV1830-0EU10 - standard PROFIBUS DP cable for fixed installation, 2-core, PVC, double-shielded, FastConnect, 8 mm diameter. Sold by the metre, minimum order 10 m. More

Code: 6XV1830-0EU10

SIEMENS6XV1830-0EU10
SIEMENS 6XV1830-0EU10 - PROFIBUS DP cable

PROFIBUS FC Standard Cable GP

Installation of PROFIBUS DP networks

Standard PROFIBUS DP cable for permanent installation

FastConnect · PVC · fixed cabling

The SIEMENS 6XV1830-0EU10 PROFIBUS FC Standard Cable GP is a shielded two-core cable for permanent installation in PROFIBUS DP networks. The FastConnect design simplifies the preparation of cable ends for connector fitting. The purple PVC sheath and the red and green conductors correspond to standard PROFIBUS cabling.

6XV1830-0EU10PVC · FastConnect

Send the required length and installation method. We will check the suitable cable version and connectors.

Permanent installationPROFIBUS FastConnect
8 mmOuter diameter of the cable
PVC sheathDouble shielding
From 10 mSold by the metre
Practical application

Use during the installation and maintenance of the network

The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.

Ordering a cable

Sold by the metre, in lengths of 10 metres or more

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

The Siemens order number refers to a version with a length of 1,000 m. FOXON dispenses this cable by the metre; the quantity ordered via the online shop is expressed in metres.

Materials

Cable construction and double shielding

The cable has 2 conductors with an inner conductor diameter of 0.65 mm. Shielding consists of overlapping aluminium-coated foil and a tinned copper braid. Both the inner and outer sheaths are PVC. The cable is not halogen-free.

SIEMENS 6XV1830-0EU10 - PROFIBUS DP cable - detail 2
SIEMENS 6XV1830-0EU10 - product details
Installation proposal

Bend radius and operating conditions

The minimum permissible bending radius is 37.5 mm for a single bend and 75 mm for repeated bending. The maximum tensile force is 100 N. The operating temperature range is -40 to +75 °C. When laying the cable, do not crush it, break it or damage the screening.

Oil resistance is defined by the IEC 60811-2-1 test: 4 hours at 70 °C. Resistance to water and fats is subject to conditions; please verify suitability for continuous exposure to a specific medium.

FastConnect and connectivity

Cable end preparation and connector assembly

This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.

When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.

PROFIBUS topology

Cable length and segment termination

The length of each segment is determined by the transmission speed, cable specifications, connectors and topology. A 1,000-metre reel does not mean that this length can be used at any speed. To extend the network and divide it into further electrical segments, select a suitable repeater or ProfiHub.

A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.

SIEMENS / PROFIBUS FC Standard Cable GP

Technical specifications for 6XV1830-0EU10

ManufacturerSIEMENS
Order number6XV1830-0EU10
Model designationPROFIBUS FC Standard Cable GP
UsesFixed PROFIBUS DP installation
Number of cores / pairs2 wires / 1 pair
WiresCopper, inner conductor diameter 0.65 mm
Wire coloursRed / green
Outer diameter8 mm ±0.4 mm
Outer sheathPVC, purple
ShieldingAluminium foil and tinned copper braiding
Halogen-freeNo
FastConnectYes
Nominal impedance150 Ω in the 3-20 MHz band
Capacitance28.5 pF/m at 1 kHz
Loop resistance, maximum110 mΩ/m
Attenuation at 4 MHz, maximum2.2 dB per 100 metres
Attenuation at 16 MHz, maximum4.2 dB / 100 m
Minimum bend radius37.5 mm for a single bend; 75 mm for repeated bending
Operating temperature-40 to +75 °C
Maximum tensile force100 N
Mass per unit length78 kg/km
Flame resistanceIEC 60332-3-24, Category C
Sales unitMetre
FOXON minimum order quantity10 m
Practical questions

Selection and correct use

Is this cable intended for use in a power chain?

The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.

How do I order the required length?

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

Is the cable halogen-free?

The cable has 2 conductors with an inner conductor diameter of 0.65 mm. Shielding consists of overlapping aluminium-coated foil and a tinned copper braid. Both the inner and outer sheaths are PVC. The cable is not halogen-free.

What bending radius should be used?

The minimum permissible bending radius is 37.5 mm for a single bend and 75 mm for repeated bending. The maximum tensile force is 100 N. The operating temperature range is -40 to +75 °C. When laying the cable, do not crush it, break it or damage the screening.

Can the FastConnect stripping tool be used?

This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.

PROFIBUS Technical Support

Why order from FOXON

We can help you select the cabling and accessories to suit your specific PROFIBUS installation. Please send us a layout diagram, a list of device designations and a description of the environment.

Selection for a specific route

We will review the cable routing, movement, temperature and requirements of the installation.

Cable and connectors

We will check the compatibility of the conductors, the shielding, the dimensions and the method of installation.

Preparing the cabling

We’ll help you choose the right tool and procedure for your specific connector.

PROFIBUS Diagnostics

We can help with signal measurement, termination and identifying the causes of communication failures.

Czech technical support

We will discuss the topology, environment and cable replacement procedure with regard to the machine operating conditions.

Delivery Confirmation

Before placing an order, we will confirm the specifications, quantity and delivery date.

Correct cablingCable routing, movement and construction
Fitting connectorsPreparation, shielding and termination
Network measurementSignal and communication quality
Documentation

Technical data sheets and installation documentation

In the ‘Downloads’ tab, you will find the current technical data sheet for the exact order number 6XV1830-0EU10. Technical data sheets are available in EN, DE and ES, along with the PROFIBUS connector handbook and the Siemens cabling selection guide.

Open downloads
SIEMENS

Technical specifications 6XV1830-0EU10

PROFIBUS FC Standard Cable GP

Identification and design

ManufacturerSIEMENS
Order number6XV1830-0EU10
Model designationPROFIBUS FC Standard Cable GP
UsesFixed PROFIBUS DP installation
Number of cores / pairs2 wires / 1 pair
WiresCopper, inner conductor diameter 0.65 mm
Wire coloursRed / green
Outer diameter8 mm ±0.4 mm
Outer sheathPVC, purple
ShieldingAluminium foil and tinned copper braiding
Halogen-freeNo
FastConnectYes

Electrical specifications

Nominal impedance150 Ω in the 3-20 MHz band
Capacitance28.5 pF/m at 1 kHz
Loop resistance, maximum110 mΩ/m
Attenuation at 4 MHz, maximum2.2 dB per 100 metres
Attenuation at 16 MHz, maximum4.2 dB / 100 m

Mechanical and operational data

Minimum bend radius37.5 mm for a single bend; 75 mm for repeated bending
Operating temperature-40 to +75 °C
Maximum tensile force100 N
Mass per unit length78 kg/km
Flame resistanceIEC 60332-3-24, Category C
Sales unitMetre
FOXON minimum order quantity10 m
Installation

Compatibility and preparation

This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.

When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.

Installation proposal

Use and delivery

The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

FAQ - 6XV1830-0EU10

Choosing the right model

Is this cable intended for use in a power chain?

The cable is designed for stationary PROFIBUS DP distribution systems in industrial installations. For regular movement within a power chain, select a suitable trailing cable. The specified permissible bending radius for repeated bending does not, in itself, guarantee service life under continuous cyclic movement.

How do I order the required length?

We sell the cable by the metre and cut it to length. The minimum order is 10 metres. Enter the required length in metres in the ‘Quantity’ field, for example 25 for a length of 25 metres. We will confirm the availability and delivery method for the specific length before you place your order.

Is the cable halogen-free?

The cable has 2 conductors with an inner conductor diameter of 0.65 mm. Shielding consists of overlapping aluminium-coated foil and a tinned copper braid. Both the inner and outer sheaths are PVC. The cable is not halogen-free.

Installation

Installation and use

What bending radius should be used?

The minimum permissible bending radius is 37.5 mm for a single bend and 75 mm for repeated bending. The maximum tensile force is 100 N. The operating temperature range is -40 to +75 °C. When laying the cable, do not crush it, break it or damage the screening.

Can the FastConnect stripping tool be used?

This cable features a FastConnect design. To prepare it, use the Siemens tool 6GK1905-6AA00 and follow the procedure for the relevant connector. Do not automatically apply the same stripping length or settings to different connectors.

How long can a single segment be?

The length of each segment is determined by the transmission speed, cable specifications, connectors and topology. A 1,000-metre reel does not mean that this length can be used at any speed. To extend the network and divide it into further electrical segments, select a suitable repeater or ProfiHub.

How do you connect the red and green wires?

When connecting, ensure that the stripped lengths and connection method comply with the specifications for the selected connector. In a standard PROFIBUS DP connection, A is the green wire and B is the red wire. The shield must make proper contact with the connector or the designated shielding element. After installation, check the wiring and network communication.

Maintenance

Operations and technical consultancy

How do you terminate a PROFIBUS segment?

A segment is a section of the network in which the electrical signal is the same. Every PROFIBUS DP metallic segment must be properly terminated at both ends with a terminating resistor that is switched on and powered. It is the physical ends of the cable run that are decisive, not the lowest and highest device addresses.

Is 150 Ω the value of the terminating resistor?

No. 150 Ω is the nominal characteristic impedance of the cable within the specified frequency band. The PROFIBUS terminator is a powered resistor network as specified in the interface design. Do not replace it with a single 150 Ω resistor.

Will a new cable sort out all the network outages?

A new cable will help if the existing cable is damaged or unsuitable. However, reliable communication requires the correct connectors, powered terminations, shielding and topology. Check the cause of any outages by measuring the entire route.