- Backup Batteries
- for SIEMENS
- SIMATIC S7-300
- Battery 6ES7971-1AA00-0AA0 for SIMATIC S7-300, (CPU 313, 314, 315)
Battery 6ES7971-1AA00-0AA0 for SIMATIC S7-300, (CPU 313, 314, 315)
Lithium backup battery for older SIEMENS SIMATIC S7-300 PLCs (CPU 313, 314, 315) with battery backup and SIMATIC S5-90U. Voltage 3.6 V; capacity 1,200 mAh; dimensions 14.5 × 24.8 mm. More
Code: 6ES7971-1AA00-0AA0
Lithium backup battery for older SIEMENS SIMATIC S7-300 PLCs (CPU 313, 314, 315) with battery backup and SIMATIC S5-90U. Voltage 3.6 V; capacity 1,200 mAh; dimensions 14.5 × 24.8 mm. More
Code: 6ES7971-1AA00-0AA0
6ES7971-1AA00-0AA0 – backup battery for SIMATIC S7-300
The compatible lithium backup battery designated 6ES7971-1AA00-0AA0 is intended for selected older SIMATIC devices. The version offered has a connector and a capacity of 1,200 mAh.
Need to confirm the correct battery configuration?
Send a photo of the battery, connector and device nameplate. We will confirm availability and the delivery date.
Battery application
Used in the corresponding older SIMATIC S7-300 and S5-90U CPUs with battery backup. Newer S7-300 CPUs with an MMC memory card often do not require a battery; the exact CPU model is decisive.
Technical specifications
| Replacement designation | 6ES7971-1AA00-0AA0 |
|---|---|
| Alternative designation | W79084-L1003-B1 |
| Voltage | 3.6 V |
| Capacity of the battery assembly offered | 1,200 mAh |
| Dimensions of the battery assembly offered | 14.5 × 24.8 mm |
| Chemistry | Li-SOCl₂; non-rechargeable |
| Cells used | Sonnenschein SL750 (SL-750) or SAFT LS14250 |
Configuration and replacement selection
Compare the connector, polarity and space available for the battery. The specifications of the compatible assembly are not the specifications of the original Siemens part; the original order number identifies the replacement required.
Scope of delivery
One compatible battery with leads and a connector.
Frequently asked questions about PLC backup batteries
What does a backup battery do in a PLC?
In battery-backed PLCs, it retains the contents of selected RAM areas when the main power supply is off. Depending on the CPU design, this covers the program, current data values or operation of the real-time clock. The particular CPU and its configuration determine what is backed up. The battery does not power normal PLC operation or its inputs and outputs.
Does every PLC need a backup battery?
No. Some CPUs retain the program and selected data without a replaceable battery. The memory architecture and exact CPU order number are decisive, rather than the series name alone. Check the documentation and battery compartment of the particular device before ordering.
How often should the battery be replaced?
For the applicable older battery-backed SIMATIC S7-300 CPUs, preventive replacement of the backup battery is recommended once a year. For other PLCs, follow the interval specified for the particular CPU. Service life depends on the current drawn by the backed-up circuits, time without main power, temperature and battery age. Record the installation date and include replacement in the maintenance plan; do not rely solely on a battery fault warning.
How do I recognise a low or faulty battery?
On the applicable older SIMATIC S7-300 CPUs, the BATF indicator signals a problem with the backup battery. A missing battery or a connection problem can also cause this indication. Assess the condition using the indicators and diagnostics of the particular CPU. BATF does not indicate the remaining backup time. First ensure that the data is backed up and resolve the fault before a planned power shutdown.
What happens if I do not replace a depleted battery?
If main power is also lost, the contents of battery-dependent memory areas may be lost or the real-time clock may stop. Depending on the CPU and memory used, the program, current data values or some of them may be lost. Battery depletion alone does not erase non-volatile memory. However, losing current data makes restarting the machine more difficult.
How do winter conditions and low temperatures affect the battery?
As temperature falls, the internal resistance of lithium cells increases and their voltage under load and usable capacity decrease. The actual battery temperature inside the device is decisive. Cold conditions therefore reduce the backup margin, especially for an older battery. Observe the temperature limits of the cell, complete battery assembly and PLC together; a wide temperature range for the cell alone does not mean that the entire device has the same tolerance.
Does high temperature shorten battery life?
Yes. In lithium backup cells, high temperature accelerates self-discharge and affects their ability to supply the required current. When planning maintenance, take account of the temperature inside the control cabinet and the storage conditions for spare batteries. Nominal capacity measured at room temperature does not guarantee the same service life in a hot control cabinet.
Should the battery be changed with the PLC powered on or off?
For the applicable older battery-backed SIMATIC S7-300 CPUs, CPU power must remain on during replacement; otherwise, data in internal memory may be lost. Power being on is not the same as RUN mode. The service procedure determines the CPU mode and machine state during the work. For other PLCs, check their own replacement procedure; this rule does not apply to every device.
What should be checked before and after replacement?
Before replacement, check that a usable backup of the program and required data is available, and check the new battery designation, connector and polarity. Record the diagnostic status and prepare the work according to the device service procedure. After replacement, check the battery indication, diagnostics and required CPU state. If the clock or operating values are backed up, check them too. Record the date and type of battery installed in the maintenance log.
Is the same voltage enough when selecting a replacement?
No. Also compare the chemistry, dimensions, capacity required by the device, connector, wire connections and polarity. The same connector with different wiring is not a suitable replacement. Do not replace a battery with connecting leads with a bare cell without checking the complete configuration.
Can I determine the remaining service life by measuring voltage?
Open-circuit voltage alone does not determine remaining capacity. In Li-SOCl₂ cells, voltage changes very little through much of the discharge; temperature and load also affect the result. Use device diagnostics and the battery manufacturer’s procedure to assess its condition. An open-circuit measurement does not replace preventive replacement.
How should a spare primary lithium battery be stored?
Keep it in its packaging, in a cool, dry place under the manufacturer’s specified conditions. Protect the connector and terminals from short circuits, and keep track of the battery designation and age. A primary lithium battery is not rechargeable: do not connect it to a charger, short-circuit it or solder directly onto the cell body. Use a suitable ready-made version with the required terminals.
Why buy a backup battery from FOXON?
Batteries for industrial equipment in one place
In one e-shop, we offer backup batteries for well-known PLCs, HMI panels, robots and other industrial equipment. Order batteries for different machines from one supplier, without searching several e-shops.
Standard batteries and custom assemblies
We supply standard batteries and custom assemblies. If you cannot find the battery in our e-shop, send a photo of the original battery or its order number. We will clarify the required specifications and arrange production of the appropriate configuration.
Help with selecting a replacement
We compare the battery designation, electrical specifications, dimensions, connector and polarity. Using a photo of the battery and device nameplate, we help identify the configuration required.
Availability and delivery date
We check current battery availability and confirm the expected delivery date before you place an order.
Battery versions available for purchase
Request a new battery in the appropriate configuration. We distinguish a compatible assembly from the device manufacturer’s original part; we will confirm the exact configuration in the quotation.
Automation spare parts and repairs
Do you also need a PLC, HMI panel or drive component for the same machine? FOXON supplies spare parts and arranges repairs of industrial electronics. Sales and repairs of automation parts.
Send us the battery designation
Include the quantity, a photo of the connector and the device nameplate. We will confirm the configuration, price and availability.