SIMODRIVE 611U error codes, fault codes and warnings: causes and remedies
List of errors and possible solutions for SIMODRIVE 611 modules
281 fault and warning entries with the original English causes, remedies, acknowledgement requirements and stop responses.
This reference reproduces section 7.3.2 of the Siemens SIMODRIVE 611 universal Function Manual (FBU), edition 04/2006, list version 09.02.04, pages 7-642 to 7-726. It is a reference for this documented system and software scope; it does not establish applicability to every SIMODRIVE 611 module or control variant.
Use the code index below, or press Ctrl+F (Command+F on Mac) to search the complete page. Each code has a direct link.
Read the original Siemens notes about this list
In some instances, the space retainers (e.g. \%u) are specified for the texts of the individual faults and warnings. In online operation with SimoCom U instead of a space retainer, an appropriate value is displayed. The complete list is updated corresponding to the Edition of this documentation (refer to the Edition in the header lines) and corresponds to the software release of ”SIMODRIVE 611 universal” documented here. The individual faults/warnings are not coded dependent on the software release.
Fault and warning code index
Choose a range, then select a code to jump to its cause and remedy.
000–09930 entries
- 000Alarm diagnostics not possible
- 001The drive does not have firmware
- 002Computation time overflow. Suppl. info: \%X
- 003NMI due to watchdog. Suppl. info: \%X
- 004Stack overflow. Suppl. info: \%X
- 005Illegal Opcode, Trace, SWI, NMI (DSP). Suppl. info: \%X
- 006Checksum test error. Suppl. info: \%X
- 007Error when initializing. Supplementary info: \%X
- 020NMI due to cycle failure
- 025SSI interrupt
- 026SCI interrupt
- 027HOST interrupt
- 028Actual current sensing during power-up
- 029Incorrect measuring circuit evaluation. Suppl. info: \%X
- 030S7 communication error. Supplementary info: \%X
- 031Internal data error. Suppl. info: \%X
- 032Incorrect number of current setpoint filters
- 033Incorrect number of speed setpoint filters
- 034Axis count function has failed
- 035Error when saving the user data. Supplementary info: \%X
- 036Error when downloading the firmware. Suppl. info: \%X
- 037Error when initializing the user data. Supplementary info: \%X
- 039Error during power section identification. Supplementary info: \%X
- 040Expected option module is not available.
- 041The firmware does not support the option module. Suppl. info: \%u
- 042Internal software error. Supplementary info \%u
- 043Firmware, option module
- 044Connection to the option module failed. Supplementary info \%X
- 045Expected option module is axially unequal
- 048Illegal status PROFIBUS hardware
100–19987 entries
- 101Target position block \%n < plus software limit switch
- 102Target position block \%n < minus software limit switch
- 103Block number \%n: Direct output function not possible
- 104Block \%n: There is no jump target
- 105Illegal mode specified in block \%n
- 106Block \%n: ABS_POS mode not possible for linear axis
- 107Block \%n: ABS_NEG mode not possible for a linear axis
- 108Block number \%n available twice
- 109External block change not requested in block \%n
- 110Selected block number \%n does not exist
- 111GOTO in block number \n not permissible
- 112Activate traversing task and start referencing, handwheel simultaneously
- 113Activate traversing task and jog, handwheel simultaneously
- 114Block change enable END in block number \%n expected
- 115Traversing range start reached
- 116Traversing range end reached
- 117Target position block \%n < start of the traversing range
- 118Target position block \%n < end of the traversing range
- 119PLUS software limit switch actuated
- 120MINUS software limit switch actuated
- 121Jog 1, jog 2 or handwheel simultaneously active
- 122Parameter \%u: value range limits violated
- 123Linear encoder for the selected dimension system illegal
- 124Referencing and jog simultaneously started
- 125Falling edge of the reference cam not identified
- 126Block \%n: ABS_POS for rotary axis, is not possible without modulo conversion
- 127Block \%n: ABS_NEG for rotary axis is not possible without modulo conversion
- 128Block \%n: Target position lies outside the modulo range
- 129Maximum velocity for a rotary axis with modulo conversion too high
- 130Controller or pulse enable withdrawn in motion
- 131Following error too high
- 132Drive located after the minus software limit switch
- 133Drive located after the plus software limit switch
- 134Positioning monitoring has responded
- 135Standstill monitoring has responded
- 136Conv.factor,feedforward contr.speed,parameter set \%d,cannot be represented
- 137Conv.factor,pos.contr.output,parameter set \%d,cannot be represented
- 138Conversion factor between the motor and load too high
- 139Modulo range and ratio do not match
- 140Minus hardware limit switch
- 141Plus hardware limit switch
- 142Input I0.x not parameterized as equivalent zero mark
- 143Endless traversing and external block change in block \%n
- 144Switching-in/switching-out MDI erroneous
- 145Fixed endstop not reached
- 146Fixed endstop, axis outside the monitoring window
- 147Enable signals withdrawn at the fixed endstop
- 148Velocity in block \%n outside the range
- 149Incorrect data for modulo axis with absolute encoder. Supplementary info \%u
- 150External position reference value < max. traversing range suppl. info \%u
- 151External position reference value < min. traversing range suppl. info \%u
- 152Pos.ref.val. and act.val. output via the bus interf. limited. Suppl. info \%X
- 160Reference cam not reached
- 161Reference cams too short
- 162No zero reference pulse present
- 163Encoderless operation and operating mode do not match
- 164Coupling released during the traversing job.
- 165Absolute positioning block not possible
- 166Coupling not possible
- 167Activate coupling signal present
- 168Overflow, buffer memory
- 169Coupling trigger missed
- 170Coupling switched-out during the traversing program
- 171Coupling not possible
- 172External block change for coupling not possible
- 173Coupling and traverse to endstop simultaneously
- 174Passive referencing not possible
- 175Passive referencing not realized. Supplementary info: \%u
- 176Absolute encoder must be adjusted
- 177Start-up passive referencing P179 not possible
- 180Teach-in without reference point
- 181Teach-in block invalid
- 182Teach-in standard block invalid
- 183Teach-in block not found
- 184Teach-in standard block not found
- 185Positioning mode invalid
- 186Spindle cannot be referenced, supplementary info \%d
- 187Conversion factor spindle pos. cannot be represented, supplementary info \%d
- 188Spindle positioning: P\%d illegal
- 189Jogging, incremental invalid
- 190Actual firmware does not support spindle positioning
- 191Zero mark setting unsuccessful
- 192Max. search velocity too high
- 193Zero mark not found
- 194Spindle positioning is only possible with motor 1
- 195Speed pre-control not permissible
- 196Illegal combination of input signals (warning \%u)
500–59918 entries
- 501Measuring circuit error, absolute current
- 504Measuring circuit error, motor measuring system
- 505Meas.circ.error motor meas.syst.abs.track
- 507Synchronization error rotor position
- 508Zero mark monitoring, motor measuring system
- 509Drive converter limiting frequency exceeded
- 512Measuring circuit error, direct measuring system
- 513Measuring circuit error, direct measuring system absolute track
- 514Zero mark monitoring, direct measuring system
- 515Power module temperature, exceeded
- 591Pos.contr.clock cycle not equal to DP clock cycle/master applic. clock cycle
- 592Spindle positioning: Pos. contr. not equal to master application clock cycle
- 593Fieldbus: Drive is not in synchronism. Supplementary info: \%X
- 595Fieldbus: Cyclic data transfer was interrupted
- 596PROFIBUS: Connection to the publisher \%u interrupted
- 597PROFIBUS: Drive not in synchronism. Supplementary information: \%X
- 598PROFIBUS: Synchronization error. Supplementary info: \%X
- 599PROFIBUS: Cyclic data transfer was interrupted
600–69921 entries
- 601Error in AD conversion, terminal 56/14 or 24/20
- 602Open-loop torque controlled oper. w/o encoder is not perm.
- 603Changeover to non-parameterized motor data set
- 604Motor encoder is not adjusted
- 605Position controller output limited
- 606Flux controller output limited
- 607Current controller output limited
- 608Speed controller output limited
- 609Encoder limit frequency exceeded
- 610Rotor position identification has failed
- 611Illegal motion during rotor position identification
- 612Illegal current during rotor position identification
- 613Shutdown limit, motor overtemperature (P1607) exceeded
- 614Delayed shutdown for motor overtemperature (P1602/P1603)
- 615DM encoder limiting frequency exceeded
- 616DC link undervoltage
- 617DC link overvoltage
- 680Illegal motor code number
- 681Illegal power section code number
- 682Illegal encoder code number in P\%u
- 683Calculate controller data was unsuccessful at first start-up (\%d)
700–79971 entries
- 703Invalid current controller cycle
- 704Invalid speed controller cycle
- 705Invalid position controller cycle
- 706Invalid interpolation cycle
- 708Axial deviations in current controller cycle
- 709Axial deviations in speed controller cycle
- 710Axial deviations in position controller or interpolation cycle
- 716Invalid torque constant
- 719Motor not parameterized for delta operation
- 720Invalid maximum motor speed
- 721Spindle speed too high
- 722Changeover speed/velocity too low
- 723Axial deviations in STS configuration
- 724Invalid motor pole pair number
- 725Invalid encoder pulse number
- 726Invalid voltage constant
- 727Invalid combination of power section and synchronous motor
- 728Torque/current adaptation factor too high
- 729Invalid motor stall current
- 731Invalid rated output
- 732Invalid rated speed
- 738Incorrect mode, analog input for the equalization controller
- 739Incorrect axis number, equalization controller
- 742V/f operation: Drive frequency, motor \%d not permissible
- 743Function is not possible using this control board
- 744Motor changeover only permissible for the closed-loop speed controlled mode
- 749Speed measuring range is not sufficient
- 751Speed controller gain too high
- 753Current, rotor position identification less than the min. value
- 756Invalid speed hysteresis of the current setpoint smoothing
- 757PZD config.: illegal frame no. in P0922
- 758Setpoint source incorrectly parameterized. Supplementary info \%u
- 759Encoder/motor types do not match
- 760Pole pair width/scale graduations cannot be represented internally
- 761P0892 cannot be used with this measuring system
- 762P0893 cannot be used with this measuring system
- 764Multiple assignment of terminal A or B (P0890)
- 765P0890 and P0891 configure both setpoint inputs
- 766Blocking frequency > Shannon frequency
- 767Natural frequency > Shannon frequency
- 768Numerator bandwidth > twice the blocking frequency
- 769Denominator bandwidth > twice the natural frequency
- 770Format error
- 771Induction motor oper.: drive converter frequency motor \%d not permissible
- 772Induction motor oper.: speed controller gain, motor \%d too high
- 773Not permissible to active analog input
- 774Induction motor oper.: changeover speed motor \%d not permissible
- 775SSI encoder incorrectly parameterized. Supplementary info \%u
- 776TTL encoder not possible for older basic module
- 777Current for the rotor position identification too high
- 778Impermissible converter frequency for rotor position ID
- 779Motor moment of inertia, motor \%d invalid
- 780No-load current, motor > rated motor current (motor \%d)
- 781No-load current, motor \%d > rated power section current
- 782Reactance motor \%d invalid
- 783Rotor resistance, motor \%d invalid
- 784No-load voltage, motor \%d invalid
- 785No-load current, motor \%d invalid
- 786Field-weakening speed, motor \%d invalid
- 787Induction motor oper.: feedforward control gain motor \%d cannot be displayed
- 788P0891 for drive B only
- 789Setpoint transfer SimoCom U ==> drive interrupted
- 790Illegal operating mode. Supplementary info: \%u
- 791TTL encoder interface incorrectly parameterized
- 792Direct measuring system incorrectly parameterized. Supplementary info: \%u
- 793Angular encoder signal waveform different for drive A and B
- 794P0890 = 3 not permitted for drive B
- 795Ang. encoder, pos. ref. value normalization factor too large. Suppl. info: \%u
- 797Error in center frequency measurement
- 798Measured value memory active
- 799FEPROM backup and HW Reset required
800–89954 entries
- 800Minus hardware limit switch
- 801Plus hardware limit switch
- 802Drive rotates in response to angular encoder output parameters
- 804Controller enable or on/off 1(edge) or on/off 2/3 missing
- 805Pulse enable missing
- 806OC/reject traversing task missing
- 807OC/intermediate stop missing
- 808Reference point not set
- 809Parking axis selected
- 814Motor temperature, pre-alarm
- 815Power module temperature, pre-alarm
- 816Resolver sensing at its limit
- 820Power module in i2t limiting
- 827Fieldbus is not in the data exchange state
- 828Fieldbus is not in clock-cycle synchronism to the master
- 829PROFIBUS: Illegal parameterization received. Reason: \%u
- 830PROFIBUS: Illegal configuration received. Reason: \%u
- 831PROFIBUS is not in the data transfer condition
- 832PROFIBUS not clock-synchronous with the master
- 833PROFIBUS: No connection to the publisher \%u
- 840Teach-in for running traversing program
- 841Teach-in for relative block
- 842Teach-in for a relative standard block
- 843Search velocity too high
- 845Jogging not effective for active coupling
- 849PLUS software limit switch actuated
- 850MINUS software limit switch actuated
- 864Parameterization error in speed controller adaptation
- 865Invalid signal number
- 866Parameterizing error, current controller adaption
- 867Generator mode: Response voltage > shutdown threshold
- 868Generator mode: Response voltage > monitoring threshold
- 869Reference point coordinate limited to modulo range
- 870Jerk: jerk time is limited
- 871Induction motor operation: drive converter frequency motor not permissible
- 872PARAMETERIZING ERROR: P gain, equalization controller too high
- 875Axial deviations in fixed voltage
- 876Terminal function \%u in the actual mode illegal
- 877Output function \%u not permissible in the actual operating mode
- 878Input I0.x not parameterized as equivalent zero mark
- 879Time constant deadtime, speed feedforward control (P0205:\%u) too high
- 881PZD configuring: Signal number in P0915:\%u invalid
- 882PZD configuring: Double word signal number in P0915:\%u invalid
- 883PZD configuring: Signal number in P0916:\%u invalid
- 884PZD configuring: Double word signal number in P0916:\%u ivalid
- 885P1261 greater than 100.0 % not permissible
- 886Pre-tensioning torque greater than 16x rated torque
- 889Fixed endstop, axis has not reached the clamping torque
- 890Acceleration – deceleration override incorrect
- 891PLUS software limit switch actuated coupled
- 892MINUS software limit switch actuated coupled
- 893Function 73 only effective at terminal I0.x
- 894Inputs, optional TERMINAL module assigned twice
- 895Outputs, optional TERMINAL module assigned twice
000Alarm diagnostics not possible
#000Cause
- Communications to the drive have been interrupted.
- Different versions of the ”SimoCom U” start-up and parameterizing tool and the drive.
Remedy
- Check the communications to the drive (cable, interfaces, ...)
- The V_611U<Version>.acc file on the hard disk of the PG/PC should be adapted to the drive as follows:
- Exit ”SimoCom U”
- Delete the V_611U<Version>.acc file (search and delete the file)
- Restart ”SimoCom U” and go online The V_611U<Version>.acc file is now re-generated and is harmonized to the drive version. Never delete the file V000000.acc!
001The drive does not have firmware
#001Cause
No drive firmware on the memory module.
Remedy
- Load the drive firmware via SimoCom U
- Insert the memory module with firmware
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
002Computation time overflow. Suppl. info: \%X
#002Cause
The computation time of the drive processor is no longer sufficient for the selected functions in the specified cycle times.
Supplementary information: only for siemens-internal error diagnostics
Remedy
Disable functions which take up a lot of computation time, e.g.:
- Variable signaling function (P1620)
- Trace function
- Start-up with FFT or analyzing the step response
- Speed feedforward control (P0203)
- Min/Max memory (P1650.0)
- DAC output (max. 1 channel) Increase cycle times:
- Current controller cycle (P1000)
- Speed controller cycle (P1001)
- Position controller cycle (P1009)
- Interpolation cycle (P1010)
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
003NMI due to watchdog. Suppl. info: \%X
#003Cause
The watchdog timer on the control module has expired. The cause is a hardware fault in the time basis on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
004Stack overflow. Suppl. info: \%X
#004Cause
The limits of the internal processor hardware stack or the software stack in the data memory have been violated. The cause is probably a hardware fault on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Power down/power up drive module
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
005Illegal Opcode, Trace, SWI, NMI (DSP). Suppl. info: \%X
#005Cause
The processor has detected an illegal command in the program memory.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
006Checksum test error. Suppl. info: \%X
#006Cause
During the continuous check of the checksum in the program/data memory, a difference was identified between the reference and actual checksum. The cause is probably a hardware fault on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
007Error when initializing. Supplementary info: \%X
#007Cause
An error occurred when loading the firmware from the memory module. Cause: Data transfer error, FEPROM memory cell defective
Supplementary information: only for siemens-internal error diagnostics
Remedy
Carry-out RESET or POWER-ON. If a download is still unsuccessful after several attempts, the memory module must be replaced. If this is unsuccessful the control module is defective and must be replaced.
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
020NMI due to cycle failure
#020Cause
Basic cycle has failed.
Possible causes: EMC faults, hardware fault, control module
Remedy
- Check the plug-in connections
- Implement noise suppression measures (screening, check ground connections)
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
025SSI interrupt
#025Cause
An illegal processor interrupt has occurred. An EMC fault or a hardware fault on the control module could be the reason.
Remedy
- Check the plug-in connections
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
026SCI interrupt
#026Cause
An illegal processor interrupt has occurred. An EMC fault or a hardware fault on the control module could be the reason.
Remedy
- Check the plug-in connections
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
027HOST interrupt
#027Cause
An illegal processor interrupt has occurred. An EMC fault or a hardware fault on the control module could be the reason.
Remedy
- Check the plug-in connections
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP VIII
028Actual current sensing during power-up
#028Cause
When the current actual value sensing runs up, or in cyclic operation at pulse inhibit, a 0 current is expected. The drive system then identifies that no currents are flowing (excessive deviation to the theoretical center frequency). It is possible that the hardware for the current actual value sensing is defective.
Remedy
- Check the plug-in connections
- Check whether the control module is correctly inserted
- Replace control module
- Replace the power section
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
029Incorrect measuring circuit evaluation. Suppl. info: \%X
#029Cause
The motor measuring system has a motor encoder with voltage output which requires a measured circuit evaluation with voltage input, or a resolver with appropriate evaluation. Another measuring circuit evaluation was identified.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Check the plug-in connections
- Implement noise suppression measures (screening, check ground connections, ...)
- Control module and encoder must be the same type (sin/cos or resolver)
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
030S7 communication error. Supplementary info: \%X
#030Cause
A fatal communication error was identified, or the drive software is no longer consistent. The cause is erroneous communications or a hardware fault on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Implement noise suppression measures (screening, check ground connections, ...)
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
031Internal data error. Suppl. info: \%X
#031Cause
Error in the internal data, e.g. errors in the element/block lists (incorrect formats, ...). The drive software is no longer consistant. The cause is propably a hardware fault on the control module.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Re-load drive software
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
032Incorrect number of current setpoint filters
#032Cause
An illegal number of current setpoint filters was entered (> 4) (maximum number = 4).
Remedy
Correct number of current setpoint filters (P1200).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
033Incorrect number of speed setpoint filters
#033Cause
An inadmissible number of speed setpoint filters (> 2) was entered (max. number = 2).
Remedy
Correct number of speed setpoint filters (P1500)
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
034Axis count function has failed
#034Cause
The function for determining the number of axes that physically exist on the power section has calculated an illegal value.
Remedy
Check that the control module is correctly inserted in the power section or whether the power section is defective.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
035Error when saving the user data. Supplementary info: \%X
#035Cause
An error occurred when saving the user data in the FEPROM on the memory module. Cause: Data transfer error, FEPROM memory cell defective
Note: The user data which was last saved, is still available as long as a new data backup was unsuccessful.
Supplementary information: only for siemens-internal error diagnostics
Remedy
Initiate another data backup. If data backup is still unsuccessful after several attempts, then the memory module must be replaced. If the user data, valid up to the error, is to be used in the new memory module, then it must be read out via SimoCom U before the memory module is replaced, and loaded again after it has been replaced.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
036Error when downloading the firmware. Suppl. info: \%X
#036Cause
An error occurred when loading a new firmware release. Cause: Data transfer error, FEPROM memory cell defective
Note: As the previously used firmware was erased when downloading, the drive expects a new firmware download after RESET or POWER ON.
Supplementary information: only for siemens-internal error diagnostics
Remedy
Execute RESET or POWER ON. If a download is still unsuccessful after several attempts, the memory module must be replaced. If this is unsuccessful the control module is defective and must be replaced.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
037Error when initializing the user data. Supplementary info: \%X
#037Cause
An error occurred when loading the user data from the memory module. Cause: Data transfer error, FEPROM memory cell defective
Supplementary information: only for siemens-internal error diagnostics
Remedy
Execute POWER ON. If a download is still unsuccessful after several attempts, the memory module must be replaced. If this is unsuccessful the control module is defective and must be replaced.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
039Error during power section identification. Supplementary info: \%X
#039Cause
Supplementary information
0x100000: More than 1 power section type was identified.
0x200000: No power section type was identified, although it would have been possible.
0x30xxxx: The identified power module differs from the entered PM (P1106). To xxxx: the code of the identified PM is entered here.
0x400000: Different power section codes (P1106) are entered for this 2-axis module.
Remedy
- Execute RESET or POWER ON
- Check whether the control module is correctly inserted in the power module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
040Expected option module is not available.
#040Cause
The parameterization (P0875) expects an option module which is not available on this control module.
Remedy
Compare the type of the expected option module (P0875) with the type of the inserted option module (P0872) and check/replace the inserted option module or cancel the option module with P0875 = 0.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
041The firmware does not support the option module. Suppl. info: \%u
#041Cause
Supplementary info = 1: An option module is inserted (P0872) or parameterized (P0875), which is not supported by the firmware release of the control module.
Remedy
Supplementary info = 1:
- Upgrade the firmware
- Use a legal option module
- Cancel the option module with P0875 = 0
Supplementary info = 2:
- Use a permissible option module (DP3)
- Cancel the option module with P0875 = 0
Supplementary info = 3:
- Replace the option module hardware DP1 by option module DP2 or DP3, without changing the drive parameters and the master configuring. The parameter for the expected option module remains at P0875 = 2.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
042Internal software error. Supplementary info \%u
#042Cause
There is an internal software error.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Execute POWER ON-RESET (press button R)
- Re-load the software into the memory module (execute software update)
- Contact the Hotline
- Replace control module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
043Firmware, option module
#043Cause
The option module does not contain the currently required firmware.
Remedy
Use a module with suitable firmware or upgrade the firmware
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
044Connection to the option module failed. Supplementary info \%X
#044Cause
The BUS coupling has failed.
Remedy
- Execute POWER ON-RESET (press button R)
- Replace option module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
045Expected option module is axially unequal
#045Cause
The option module type, expected from the parameterization, is different for the two axes of a two-axis module.
Remedy
Set the expected option module type in P0875 the same for both axes, or cancel for axis B by setting P0875 to 0.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
048Illegal status PROFIBUS hardware
#048Cause
An illegal status of the PROFIBUS controller was recognized.
Remedy
- Execute POWER-ON RESET
- Check the PROFIBUS unit screw connection
- Replace drive module
- Acknowledgement
- POWER ON
- Stop response
- STOP II
101Target position block \%n < plus software limit switch
#101Cause
The target position specified in this block lies outside the range limited by P0316 (plus software limit switch).
Remedy
- Change the target position in the block
- Set the software limit switches differently
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
102Target position block \%n < minus software limit switch
#102Cause
The target position specified in this block lies outside the range limited by P0315 (minus software limit switch).
Remedy
- Change the target position in the block
- Set the software limit switches differently
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
103Block number \%n: Direct output function not possible
#103Cause
For the SET_O or RESET_O command, an illegal value was entered in P0086:64 (command parameter).
Remedy
Enter value 1, 2 or 3 in P0086:64 (command parameter).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
104Block \%n: There is no jump target
#104Cause
A jump is programmed to a non-existent block number in this traversing block.
Remedy
Program the existing block number.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
105Illegal mode specified in block \%n
#105Cause
Illegal data is in P0087:64/P0097 (mode). A data position in P0087:64/P0097 has an inadmissible value.
For the commands SET_O and RESET_O, the CONTINUE EXTERNAL block change enable is not permissible.
For MDI: The configuration of the external block change P0110 is incorrect. The external block change is only permissible with P0110 = 2 or 3. Block change enable only with ”END” or ”CONTINUE EXTERNAL”.
For axis couplings: For COUPLING_IN/COUPLING_OUT via a traversing block (P0410 = 3, 4 or 8), a block change enable with CONTINUE FLYING is not possible.
Remedy
Check and correct P0087:64/P0097.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
106Block \%n: ABS_POS mode not possible for linear axis
#106Cause
For a linear axes, the positioning mode ABS_POS was programmed (only for rotary axes).
Remedy
Change P00987:64/P0097 (mode).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
107Block \%n: ABS_NEG mode not possible for a linear axis
#107Cause
For a linear axes, the positioning mode ABS_NEG was programmed (only for rotary axes).
Remedy
Change P00987:64/P0097 (mode).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
108Block number \%n available twice
#108Cause
There are several traversing blocks with the same block number in the program memory. The block numbers must be unique over all traversing blocks.
Remedy
Assign unique block numbers.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
109External block change not requested in block \%n
#109Cause
External block change was not requested for a traversing block with block step enable CONTINUE EXTERNAL and P0110 (configuration of external block change) = 0.
Remedy
Remove the cause that the signal edge is missing at the input terminal or for a PROFIBUS control signal STW1.13 or for the appropriate fieldbus signal.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
110Selected block number \%n does not exist
#110Cause
A block number was selected which is not available in the program memory or has been suppressed.
Remedy
Select the existing block number. Program the traversing block with the selected block number.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
111GOTO in block number \n not permissible
#111Cause
The step command GOTO may not be programmed for this block number.
Remedy
Program another command.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
112Activate traversing task and start referencing, handwheel simultaneously
#112Cause
A positive signal edge was simultaneously detected for the input signals ”Activate traversing task” and ”Start referencing” and ”Activate handwheel”. At power-on or POWER-ON RESET, if both input signals have a ”1” signal, then for both signals a 0/1 edge (positive edge) is simultaneously identified.
Remedy
Reset both input signals, and re-start the required function after the fault has been acknowledged.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
113Activate traversing task and jog, handwheel simultaneously
#113Cause
A positive signal edge was simultaneously detected for the input signals ”Activate traversing task” and ”Jog 1”, ”Jog 2” and ”Activate handwheel”. At power-on or POWER-ON RESET, if both input signals have a ”1” signal, then for both signals a 0/1 edge (positive edge) is simultaneously identified.
Remedy
Reset both input signals, and re-start the required function after the fault has been acknowledged.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
114Block change enable END in block number \%n expected
#114Cause
The traversing block with the highest block number does not have END as block step enable.
Remedy
- Program this traversing block with block step enable END.
- Program the GOTO command for this traversing block.
- Program additional traversing blocks with higher block number and program the block step enable END (highest block number) in the last block.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
115Traversing range start reached
#115Cause
The axis has moved to the traversing range limit in a block with the command ENDLOS_NEG (–200 000 000 MSR).
Remedy
- Acknowledge fault
- Move away in the positive direction (e.g. jog)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
116Traversing range end reached
#116Cause
The axis has moved to the traversing range limit in a block with the command ENDLOS_POS (200 000 000 MSR).
Remedy
- Acknowledge fault
- Move away in the negative direction (e.g. jog)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
117Target position block \%n < start of the traversing range
#117Cause
The target position specified in this block lies outside the absolute traversing range (–200 000 000 MSR).
Remedy
Change the target position in the block
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
118Target position block \%n < end of the traversing range
#118Cause
The target position specified in this block lies outside the absolute traversing range (200 000 000 MSR).
Remedy
Change the target position in the block
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
119PLUS software limit switch actuated
#119Cause
For a block with the ENDLOS_POS command, the axis has actuated the plus software limit switch (P0316) for absolute or relative positioning. The behavior for software limit switch reached, can be set using P0118.0.
Remedy
- Acknowledge fault
- Move away in the negative direction, jog mode
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
120MINUS software limit switch actuated
#120Cause
For a block with the ENDLOS_NEG command, the axis has actuated the minus software limit switch (P0315) for absolute or relative positioning. The behavior for software limit switch reached, can be set using P0118.0.
Remedy
- Acknowledge fault
- Move away in the positive direction, jog mode
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
121Jog 1, jog 2 or handwheel simultaneously active
#121Cause
The input signals ”jog 1”, ”jog 2” or ”activate handwheel” were simultaneously activated.
Remedy
- Reset both input signals
- Acknowledge the fault
- Activate the required input signal
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
122Parameter \%u: value range limits violated
#122Cause
The value range limit of the parameter was violated when the dimension system was changed over from inches to millimeters.
Remedy
Place the parameter value within the value range.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
123Linear encoder for the selected dimension system illegal
#123Cause
For a linear encoder, the dimension system was set to degrees.
Remedy
Change the dimension system setting (P0100).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
124Referencing and jog simultaneously started
#124Cause
For the ”start referencing” and ”Jog 1” and ”Jog 2” input signals, a positive edge was simultaneously identified.
Remedy
Reset both input signals, and re-start the required function after the fault has been acknowledged.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
125Falling edge of the reference cam not identified
#125Cause
When moving away from the reference cams, the traversing range limit was reached, as the 1/0 edge of the reference cam was not identified.
Remedy
Check the ”reference cam” input signal and repeat the reference point approach.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
126Block \%n: ABS_POS for rotary axis, is not possible without modulo conversion
#126Cause
The ABS_POS positioning mode is only permitted for a rotary axis with activated module conversion (P0241 = 1).
Remedy
Use the valid positioning mode for this axis type.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
127Block \%n: ABS_NEG for rotary axis is not possible without modulo conversion
#127Cause
The ABS_NEG positioning mode is only permitted for a rotary axis with activated modulo conversion (P0241 = 1).
Remedy
Use the valid positioning mode for this axis type.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
128Block \%n: Target position lies outside the modulo range
#128Cause
The programmed target position (P0081:64/P0091) is outside the selected modulo range (P0242).
Remedy
Program valid target position.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
129Maximum velocity for a rotary axis with modulo conversion too high
#129Cause
The programmed maximum velocity (P0102) is too high to correctly calculate the modulo offset. The maximum velocity may only be so high, that 90% of the modulo range (P0242) can be traveled through within one interpolation cycle (P1010).
Remedy
Reduce maximum velocity (P0102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
130Controller or pulse enable withdrawn in motion
#130Cause
Possible causes are:
- One of the following enable signals was withdrawn while moving: Terminals 48, 63, 64, 663, 65.x, PROFIBUS or bus enable signals, PC enable from SimoCom U
- Another fault has occurred, which causes the controller or pulse enable to be withdrawn
- The drive is in the power-on inhibit state
Remedy
- Set the enable signals or check the cause of the first fault which occurred and remove
- Remove the power-on inhibit with the edge (0 ––> 1) at control word STW1.0 or terminal 65.
- Withdraw the power-on inhibit from the fieldbus signal.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
131Following error too high
#131Cause
Possible causes are:
- The torque or acceleration capability of the drive is exceeded
- Position measuring system fault
- The position control sense is not correct (P0231)
- Mechanical system blocked
- Excessive traversing velocity or excessive position setpoint differences
Remedy
Check the above causes and remove.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
132Drive located after the minus software limit switch
#132Cause
The axis was moved to the minus software limit switch (P0315), jog mode. The fault can also occur if the software limit switches are inactive if the position actual value falls below the limit value of –200 000 000 MSR, that corresponds to 555 revolutions for a rotary axis.
Remedy
Return the drive into the traversing range using jog button 1 or 2. Then acknowledge the fault.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP III
133Drive located after the plus software limit switch
#133Cause
The axis was moved to the plus software limit switch (P0316), jog mode. The fault can also occur if the software limit switches are inactive if the position actual value exceeds the limit value of 200 000 000 MSR, that corresponds to 555 revolutions for a rotary axis.
Remedy
Return the drive into the traversing range using jog button 1 or 2. Then acknowledge the fault.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP III
134Positioning monitoring has responded
#134Cause
The drive has not yet reached the positioning window (P0321) after the positioning monitoring time (P0320) has expired.
Possible causes:
- Positioning monitoring time (P0320) parameters too low
- Positioning window (P0321) parameters too low
- Position loop gain (P0200) too low
- Position loop gain (P0200) too high (instability/tendency to oscillate)
- Mechanical block
Remedy
Check above parameters and correct.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
135Standstill monitoring has responded
#135Cause
The drive has left the standstill window (P0326) after the standstill monitoring time (P0325) has expired. Possible causes are:
- Position actual value inversion (P0231) incorrectly set
- Standstill monitoring time (P0325) parameters too low
- Standstill window (P0326) parameters too low
- Position loop gain (P0200) too low
- Position loop gain (P0200) too high (instability/tendency to oscillate)
- Mechanical overload
- Check connecting cable motor/converter (phase missing, exchanged)
Remedy
Check above parameters and correct.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
136Conv.factor,feedforward contr.speed,parameter set \%d,cannot be represented
#136Cause
The conversion factor in the position controller between velocity and speed cannot be displayed. This factor depends on the following parameters:
- Spindle pitch (P0236), for linear axes
- Gearbox ratio (P0238:8/P0237:8).
Remedy
Check the above mentioned parameters and correct.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
137Conv.factor,pos.contr.output,parameter set \%d,cannot be represented
#137Cause
The conversion factor in the position controller between the following error and the speed setpoint cannot be displayed. This factor depends on the following parameters:
- Spindle pitch (P0236) (for linear axes)
- Gearbox ratio P0238:8/P0237:8
- Position control loop gain P0200:8
Remedy
Check the above mentioned parameters and correct.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
138Conversion factor between the motor and load too high
#138Cause
The conversion factor between the motor and load is greater than 2 to the power of 24 or less than 2 to the power of –24.
Remedy
Check the following parameters and correct: P0236, P0237, P0238, P1005, P1024
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
139Modulo range and ratio do not match
#139Cause
For multi-turn absolute value encoders, the ratio between the encoder and load must be selected so that the complete encoder range is an integer multiple of the modulo range. The following condition must be fulfilled: P1021 * P0238:8 / P0237:8 * 360 / P0242 must be integer numbers.
Remedy
- Check and correctP1021, P0238:8, P0237:8
- Adapt the modulo range (P0242)
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
140Minus hardware limit switch
#140Cause
A 1/0 edge was identified at the ”Minus hardware limit switch” input signal.
Remedy
Return the drive into the traversing range using jog button 1 or 2. Then acknowledge the fault.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP III
141Plus hardware limit switch
#141Cause
A 1/0 edge was identified at the ”Plus hardware limit switch” input signal.
Remedy
Return the drive into the traversing range using jog button 1 or 2. Then acknowledge the fault.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP III
142Input I0.x not parameterized as equivalent zero mark
#142Cause
When entering an external signal as equivalent zero mark (P0174 = 2), input I0.x must be assigned ”equivalent zero mark” function (Fct. No.:79). if a direct measuring system is used, input I0.B must be assigned the ”equivalent zero mark” function (Fct. No.: 79).
Remedy
- Motor measuring system: P0660 = 79
- Direct measuring system: P0672 = 79
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
143Endless traversing and external block change in block \%n
#143Cause
The block change enable CONTINUE_EXTERNAL for the ENDLESS_POS or ENDLESS_NEG command is only permitted with P0110 = 0 or 1.
Remedy
Block change enable or change P0110.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
144Switching-in/switching-out MDI erroneous
#144Cause
In the active traversing program, MDI was switched-in or, in the active MDI block, MDI was switched-out.
Remedy
Acknowledge fault Change P0110
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
145Fixed endstop not reached
#145Cause
In a traversing block with the FIXED ENDSTOP command, the fixed endstop was not reached. The fixed endstop lies outside the position programmed in this block. After interrupting the traverse to fixed endstop function, the drive was forced out of the position (support position).
Remedy
Check programming Increase kP0326 if the drive was forced out of the position.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
146Fixed endstop, axis outside the monitoring window
#146Cause
In the ”Fixed endstop reached” status, the axis has moved outside the defined monitoring window.
Remedy
- Check P0116:8 (fixed endstop, monitoring window)
- Check mechanical system
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
147Enable signals withdrawn at the fixed endstop
#147Cause
Possible causes are:
- One of the following enable signals was withdrawn while traversing to the fixed endstop: Terminals 48, 63, 64, 663, 65.x, PROFIBUS and bus enable signals, PC enable from SimoCom U
- Another fault has occurred, which causes the controller or pulse enable to be withdrawn
Remedy
Set the enable signals and check the cause of the first fault and remove.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
148Velocity in block \%n outside the range
#148Cause
The velocity, specified in this block lies outside the range (1 000 to 2 000 000 000 c*MSR/min).
Remedy
Change the velocity in the block
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
149Incorrect data for modulo axis with absolute encoder. Supplementary info \%u
#149Cause
Data error for modulo drive with absolute encoder and any gear factor.
- Data was not able to be saved after power-on.
- Absolute position was not able to be read-out of the encoder.
Supplementary information: only for siemens-internal error diagnostics
Remedy
- Adjust the drive by setting the absolute value.
- Check the switching threshold in P1162 (minimum DC link voltage).
- Check the hysteresis of the DC link voltage monitoring in P1164.
- Acknowledgement
- POWER ON
- Stop response
- STOP V
150External position reference value < max. traversing range suppl. info \%u
#150Cause
The external position reference value has exceeded the upper traversing range limit.
Supplementary info = 0: Limit exceeded after the coupling factors P0401/P0402 identified, i.e.
P0032 > 200 000 000 MSR.
Supplementary info = 1: Limit exceeded after the coupling factors P0401/P0402 identified, i.e. P0032 * P0402 / P0401 > 200 000 000 MSR.
Remedy
Return the external position reference value to the value range. Then acknowledge the fault.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
151External position reference value < min. traversing range suppl. info \%u
#151Cause
The external position reference value has fallen below the lower traversing range limit.
Supplementary info = 0: Limit fallen below after the coupling factors P0401/P0402 identified, i.e.
P0032 < – 200 000 000 MSR.
Supplementary info = 1: Limit fallen below after the coupling factors P0401/P0402 identified, i.e. P0032 * P0402 / P0401 < – 200 000 000 MSR.
Remedy
Return the external position reference value to the value range. Then acknowledge the fault.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
152Pos.ref.val. and act.val. output via the bus interf. limited. Suppl. info \%X
#152Cause
The output of the position reference value, position actual value or position correction value is parameterized via PROFIBUS or the bus interface. However, the value to be output can no longer be represented in 32 bits and was therefore limited to the maximum values 0x7fffffff or 0x80000000. The traversing range which can be displayed is given by Lower limit: – 2147483648 * P896 / P884 Upper limit: + 2147483647 * P896 / P884 The supplementary information explains which process data has violated the lower or upper limit:
Supplementary info process data Violation xx1 Position reference value Xset (No. 50208) Upper limit exceeded xx1 Position reference value Xset (No. 50208) Lower limit fallen below x1x Position actual value Xact (No. 50206) Upper limit exceeded x2x Position actual value Xact (No. 50206) Lower limit fallen below 1xx Position correction value dxKorr (No. 50210) Upper limit exceeded 2xx Position correction value dxKorr (No. 50210) Lower limit fallen below
Remedy
- Move drive back e.g. by jogging in the representable traversing range.
- Adapt the lower and upper limit to the required traversing range using P884 and P896.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP III
160Reference cam not reached
#160Cause
After starting the reference point approach, the axis moves through the distance in P0170 (max. distance to the reference cam) without finding the reference cam.
Remedy
- Check the ”reference cam” signal
- Check P0170
- If it is an axis without reference cam, then set P0173 to 1
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
161Reference cams too short
#161Cause
When the axis moves to the reference cam, and does not come to a standstill at the cam, then this error is signaled, i.e. the reference cam is too short.
Remedy
- Set P0163 (reference point approach velocity) to a lower value
- Increase P0104 (maximum deceleration)
- Use larger reference cam
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
162No zero reference pulse present
#162Cause
- After the reference cam has been left, the axis has moved through the distance in P0171 (max. distance between the reference cam/zero pulse), without finding a zero pulse.
- For distance-coded measuring system (from SW 8.3 onwards): The maximum permissible distance (clearance) between two reference marks was exceeded.
Remedy
- Check the encoder with reference to the zero mark
- Set P0171 to a higher value
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
163Encoderless operation and operating mode do not match
#163Cause
Encoderless operation was parameterized (P1006) and the ”Positioning” mode selected.
Remedy
Set operating mode ”speed/torque setpoint” (P0700 = 1)
- Acknowledgement
- POWER ON
- Stop response
- STOP V
164Coupling released during the traversing job.
#164Cause
The coupling was disconnected while a traversing task was running
Remedy
First exist the traversing task and then disconnect the coupling.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP III
165Absolute positioning block not possible
#165Cause
Traversing blocks with absolute position data are not permitted while the axis coupling is activated.
Remedy
Correct traversing block
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
166Coupling not possible
#166Cause
- No coupling can be established in the actual operating status.
- For P0891=2 or 3, it is not possible to couple using the input signal ”Activate coupling through I0.x” (fast input).
Remedy
- Check the coupling configuration (P0410)
- Set angular encoder interface (P0890, P0891)
- Check the source of the external position reference value and input signal source.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
167Activate coupling signal present
#167Cause
- The input signal ”Activate coupling” is present. An edge of the input signal is necessary to activate the coupling.
- In the jog mode, while traversing, the input signal ”coupling on” was entered.
- The ”coupling in” input signal was entered in handwheel operation.
Remedy
Reset ”Activate coupling” input signal Acknowledge fault Set the input signal again to switch-in the coupling
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
168Overflow, buffer memory
#168Cause
Occurs for couplings with queue functionality. A maximum of 16 positions can be saved in P0425:16.
Remedy
Ensure that maximum 16 positions are saved.
- Acknowledgement
- POWER ON
- Stop response
- STOP IV
169Coupling trigger missed
#169Cause
Occurs for couplings with queue functionality. Synchronizatin is requested using the KOPPLUNG_ON command and it is identified that the position at which the coupling is switched-in, has already bee passed.
Remedy
Ensure that the slave drive was stationary for at least 1 IPO clock cycle (P1010), before the coupling for the next element in the position memory must be switched-in.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
170Coupling switched-out during the traversing program
#170Cause
While the drive was executing a traversing program, the ”Activate coupling” input signal was reset.
Remedy
Only switch-out the coupling if the traversing program has been completed.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
171Coupling not possible
#171Cause
While the drive was executing a traversing program, the ”Active coupling” input signal was set.
Remedy
Only switch-in the coupling if the traversing program has been completed.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
172External block change for coupling not possible
#172Cause
If there is an existing coupling, traversing blocks with external block enable are only permitted if P0110 = 2.
Remedy
Correct traversing program Change P0110 (configuration, external block change)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
173Coupling and traverse to endstop simultaneously
#173Cause
Not possible to simultaneously couple and traverse to the endstop.
Remedy
Correct traversing program
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP V
174Passive referencing not possible
#174Cause
For the passive referencing, the encoder interface must be switched as input and the ”Positioning” mode must be set.
Remedy
- Set the ”Positioning” mode (P0700)
- Set angular encoder interface (P0890, P0891)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
175Passive referencing not realized. Supplementary info: \%u
#175Cause
While the master drive corrects the zero mark offset, the slave drive must pass over a zero mark.
Supplementary information 0 = Reference cam not found 1 = Reference cam not left 2 = Zero reference pulse not found
Remedy
Ensure that the cam of the slave drive is located between the cam and the reference point of the master drive. Appropriately shift the cam and/or increase the reference point offset (P0162) at the master drive. If the zero pulse is not found, the reference point offset (P0162) must also be increased at the master drive.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
176Absolute encoder must be adjusted
#176Cause
Passive referencing with absolute encoders (e.g. EnDat encoders) is only possible after the encoder has been adjusted.
Remedy
Adjust the drive by setting the absolute value.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
177Start-up passive referencing P179 not possible
#177Cause
The start-up help for passive referencing determines the reference point offset in P0162 in the slave drive. The following prerequisites must be available:
- (permanent) position coupling exists to the master drive
- Master drive must be precisely at its reference point
- Slave drive has passed the zero mark.
Remedy
- Establish a coupling at the slave drive: PosStw.4 or input terminal function 72/73
- Reference the master drive: STW1.11 or input terminal function 65 at the master drive
- ”Wiring” check: The requirement for passive referencing must be transferred from the master to the slave drive: Masterdrive: Output via ZSW1.15, QZsw.1 or output terminal function 69 Slave drive: read-in via STW1.15, QStw.1 or input terminal function 69
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
180Teach-in without reference point
#180Cause
Teach-in only possible for a referenced axis.
Remedy
Request reference axis and teach in
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
181Teach-in block invalid
#181Cause
The specified teach-in block is invalid.
Remedy
Specify the valid and existing traversing block.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
182Teach-in standard block invalid
#182Cause
The specified teach-in standard block is invalid.
Remedy
Specify the valid and existing traversing block.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
183Teach-in block not found
#183Cause
The specified teach-in block is not found.
Remedy
Select the valid and existing traversing block. Activate ”Automatically search for block numer” function.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
184Teach-in standard block not found
#184Cause
The specified teach-in standard block is not found.
Remedy
Generate the required standard block for the specified block number Enter the correct block number.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP IV
185Positioning mode invalid
#185Cause
For the ”Spindle positioning” function, the positioning mode (P0087) is not valid.
Remedy
Program traversing block positioning as absolute, absolute positive or absolute negative.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
186Spindle cannot be referenced, supplementary info \%d
#186Cause
For the ”Spindle positioning” function, an error has occurred while positioning. Suppl. info Significance 0 The distance between the last two zero marks was not correct. 1 For two revolutions a zero mark was no longer detected, which was in a tolerance bandwidth of P0126.
Remedy
Check cable and connections.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
187Conversion factor spindle pos. cannot be represented, supplementary info \%d
#187Cause
Conversion factors for spindle positioning was not able to be intialized
Supplementary info, ones and tens position:
00: Conversion factor, velocity to speed too small
01: Conversion factor, velocity to speed too high
02: Conversion factor, adaptation filter too low (–> increase P0210)
03: Conversion factor, adaptation filter too high (–> reduce P0210)
04: Conversion factor, pre-control balancing filter too low (–> increase P0206)
05: Conversion factor, pre-control balancing filter too high (–> reduce P0206)
06: Conversion factor, sum delay too small
07: Conversion factor, sum delay too large
08: Conversion factor, following error model too small
09: Conversion factor, following error model too large The hundreds position of the supplementary info contains the parmeter set involved.
Remedy
Check and correct specified parameters.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
188Spindle positioning: P\%d illegal
#188Cause
Spindle positioning requires the following parameteriation:
P0241 = 1
P0100 = 3
Remedy
Correct the specified parameter or cancel spindle positioning by setting P0125 to 0.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
189Jogging, incremental invalid
#189Cause
1. Jogging incremental is not valid in this mode.
2. An attempt was made to move an axis away from a software limit switch using incremental jogging – however the axis is not at the software limit switch, but behind it.
3. An attempt was made while executing one or several traversing blocks (also via an axis coupling) to activate incremental jogging.
Remedy
1. Commission the drive in the positioning mode.
2. Move back with jog key 1 or 2 with velocity.
3. Interrupt traversing blocks with the operating condition, reject traversing task.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP VI
190Actual firmware does not support spindle positioning
#190Cause
This firmware does not support the spindle positioning function.
Remedy
Set parameter P0125 to 0
- Acknowledgement
- POWER ON
- Stop response
- STOP II
191Zero mark setting unsuccessful
#191Cause
It is not possible to set the internal zero mark, if
1. Input signal ”Spindle positioning on” is set, or
2. Still no zero mark found.
Remedy
Maintain the following sequence:
1. Execute spindle positioning ––> zero mark found
2. Withdraw input signal ”spindle positioning on”
3. Set the internal zero mark (P0127=1).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
192Max. search velocity too high
#192Cause
The maximum search velocity for spindle positioning is greater than the maximum motor speed.
Remedy
Reduce parameter P0133 or reduce the velocity in the traversing block.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
193Zero mark not found
#193Cause
The zero mark (encoder or equivalent zero mark, e.g. BERO) was not found. Gearbox ratio (mechanical system) was not correctly parameterized using parameter P0237/P0238.
Remedy
- Check the equivalent zero mark (BERO) function, if required, replace the BERO
- Readjust the clearance when using BERO
- Check the cabling
- Correctly parameterize the gearbox ratio (mechanical system) using parameter P0237/P0238
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
194Spindle positioning is only possible with motor 1
#194Cause
Spindle positioning is only possible with motor 1.
Remedy
Activate motor data set 1 before the spindle positioning command.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
195Speed pre-control not permissible
#195Cause
Speed pre-control is not permissible with spindle positioning.
Remedy
Cancel the speed pre-control (P0203)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
196Illegal combination of input signals (warning \%u)
#196Cause
An illegal combination of signals is present at the inputs, at the Profibus control words or at the appropriate bus signals. The detailed cause of the error can be taken from the help text associated with the warning that is entered as supplementary information. This fault can be activated or suppressed using Parameter P338.
Supplementary information: Warning number
Remedy
Change the input signals or suppress the fault using P338.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
501Measuring circuit error, absolute current
#501Cause
1. The smoothed absolute current (P1254, current monitoring time constant) is greater than 120 % of the permissible power section current (P1107).
2. For an active rotor position identification, the permissible current threshold was exceeded.
3. The P gain of the controller (P1120) has been set too high.
Remedy
- Motor/controller data not correct
- For active rotor position identification P1019 (current, rotor position identification) check and if required reduce
- Reduce the P gain of current controller (P1120), check the current controller adaptation (P1180, P1181, P1182)
- Replace control module
- Replace the power section
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
504Measuring circuit error, motor measuring system
#504Cause
The encoder signal level is too low, faulted (incorrect shielding), or the cable breakage monitoring function has responded. After separately shutting down the supply voltage at the drive, for SIMODRIVE 611 universal HRS with 1Vpp encoder or SIMODRIVE universalE HRS with 1Vpp encoder, this fault message can be output during the shutdown procedure without any significance for the control.
Remedy
- Use the original Siemens pre-assembled encoder cables (better screening)
- Check for sporadic interruptions (loose contact, e.g. when the drag cable is being moved)
- For toothed-wheel encoders, check the clearance between the toothed wheel and sensor
- Check the encoder, encoder cables and connectors between the motor and control module
- Check the screen connection at the front panel of the control module (top screw)
- Replace the encoder cables or the control module
- Exchange the encoder or motor
- If this fault was signaled without any significance, then it should either be acknowledged in the control or the drive and control should be powered-down together.
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
505Meas.circ.error motor meas.syst.abs.track
#505Cause
1. The motor absolute track (CD track) is monitored for an interrupted conductor. For optical encoders, the absolute track supports the evaluation of the mechanical position within one motor revolution.
2. For absolute encoders with EnDat interface, this fault displays an initialization error.
Note: Additional information on the reason for the fault is included in P1023 (IM diagnostics).
Remedy
- Incorrect encoder cable type
- Check for sporadic interruptions (loose contact, e.g. when the drag cable is being moved)
- Remove noise which is coupled in due to inadequate screening of the cable by replacing the encoder cable
- Incorrect encoder type configured (e.g. ERN instead of EQN)
- Check the encoder, encoder cables and connectors between the motor and control module
- Replace control module
- Replace encoder
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
507Synchronization error rotor position
#507Cause
The difference between the actual rotor position and the new rotor position, which was determined by fine synchronization is greater than 45 degrees electrical. When commissioning a linear motor with rotor position identification (e.g. linear motor, 1FE1 motor), the fine synchronization was not adjusted.
Remedy
- Adjust the fine synchronization using P1017 (commissioning help function)
- Check encoder cable, encoder cable connection and grounding (possibly EMC problems)
- Check the shield contact, front panel, control module (upper screw)
- Replace control module
- Exchange the encoder or motor
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
508Zero mark monitoring, motor measuring system
#508Cause
The measured rotor position fluctuates between 2 encoder zero marks (encoder lines may have been lost).
Note: The encoder monitoring function can be disabled using P1600.8.
Remedy
- Use the original Siemens pre-assembled encoder cables (better screening)
- Check for sporadic interruptions (loose contact, e.g. due to cable drag movements)
- For toothed-wheel encoders, check the clearance between the toothed wheel and sensor
- Check the encoder, encoder cables and connectors between the motor and control module
- Check the shield contact, front panel, control module (upper screw)
- Replace the encoder cables or the control module
- Replace control module
- Exchange the encoder or motor
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
509Drive converter limiting frequency exceeded
#509Cause
The speed actual value has exceeded the maximum permissible value.
Remedy
- Encoder pulse number is too low, enter the actual encoder pulse number in P1005
- Stop the belt slipping in open-loop torque controlled mode (the belt slips)
- Check P1400 (rated motor speed)
- Check P1146 (maximum motor speed)
- Check P1147 (speed limiting)
- Check P1112 (motor pole pair number)
- Check P1134 (rated motor frequency)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
512Measuring circuit error, direct measuring system
#512Cause
The encoder signal level is too low, faulted (incorrect shielding), or the cable breakage monitoring function has responded.
Remedy
- Use the original Siemens pre-assembled encoder cables (better screening)
- Check for sporadic interruptions (loose contact, e.g. due to cable drag movements)
- For toothed-wheel encoders, check the clearance between the toothed wheel and sensor
- Check the encoder, encoder cables and connectors between the encoder and control module
- Check the shield contact, front panel, control module (upper screw)
- Replace the encoder cables or the control module
- Replace encoder
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
513Measuring circuit error, direct measuring system absolute track
#513Cause
For absolute encoders with EnDat interface, this fault indicates an initialization error.
Note: Additional information on the reason for the fault is included in P1033 (DM diagnostics).
Remedy
- Incorrect encoder cable type
- Check for sporadic interruptions (loose contact, e.g. when the drag cable is being moved)
- Remove noise which is coupled in due to inadequate screening of the cable by replacing the encoder cable
- Incorrect encoder type configured (e.g. ERN instead of EQN)
- Check the encoder, encoder cables and connectors between the encoder and control module
- Replace control module
- Replace encoder
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
514Zero mark monitoring, direct measuring system
#514Cause
A fluctuation in the measured values has occurred between 2 encoder zero marks (encoder pulses may have been lost).
Note: The encoder monitoring can be disabled using P1600.14.
Remedy
- Use the original Siemens pre-assembled encoder cables (better screening)
- Check for sporadic interruptions (loose contact, e.g. due to cable drag movements)
- For toothed-wheel encoders, check the clearance between the toothed wheel and sensor
- Check the encoder, encoder cables and connectors between the motor and control module
- Check the shield contact, front panel, control module (upper screw)
- Replace the encoder cables or the control module
- Replace encoder
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
515Power module temperature, exceeded
#515Cause
The power section temperature is sensed using a temperature sensor on the heatsink. The drive is immediately shut down 20 seconds after the heatsink temperature alarm in order to prevent the power section being thermally destroyed (regenerative stop).
Remedy
Improve the drive module cooling, e.g. using:
- Higher airflow in the switching cabinet, possibly cool the ambient air of the drive modules
- Avoid many acceleration and braking operations which follow quickly one after the other
- Check that the power section for the axis/spindle is adequate, otherwise use a higher-rating module
- Ambient temperature too high (refer to the Planning Guide)
- Permissible installation altitude exceeded (refer to the Planning Guide)
- Pulse frequency too high (refer to the Planning Guide)
- Check fan, if required, replace
- Maintain the minimum clearance above and below the power section (refer to the Planning Guide)
- Acknowledgement
- POWER ON
- Stop response
- parameterizable
591Pos.contr.clock cycle not equal to DP clock cycle/master applic. clock cycle
#591Cause
For a 2-axis module, one axis is in the n-set mode and one axis in the positioning mode. For the axis in the n-set mode, a position controller clock cycle (of the master) is entered via the clock-cycle synchronous Profibus or the bus interface. This position controller clock cycle differs from the parameterized position controller clock cycle (P1009) of the axis in the positioning mode. The position controller clock cycle of the master is obtained, in the n-set mode, from the DP clock cycle (Tdp) or the clock cycle of the bus interface multiplied by the time grid Tmapc.
Remedy
For a clock cycle synchronous PROFIBUS (isochronous) or the bus interface, the clock cycles configured for the bus (parameterization) are aligned with the position controller clock cycle P1009 from the positioning axis and n-set axis.
- Acknowledgement
- POWER ON
- Stop response
- STOP II
592Spindle positioning: Pos. contr. not equal to master application clock cycle
#592Cause
The function ”spindle positioning” requires, for a clock-cycle synchronous PROFIBUS or the bus interface, that the position controller clock cycle of the master matches the parameterized position controller clock cycle (P1009). The position controller clock cycle of the master is obtained from the DP clock cycle (Tdp) multiplied by the time grid Tmapc.
Remedy
For the clock-cycle synchronous PROFIBUS or the bus interface, the clock cycles configured for the bus (parameterization) are aligned with the position controller clock cycle P1009.
- Acknowledgement
- POWER ON
- Stop response
- STOP II
593Fieldbus: Drive is not in synchronism. Supplementary info: \%X
#593Cause
Supplementary information
0x01: The master sign-of-life has more consecutive failures than permitted. The permissible sign-of-life errors are specified using P0879 bits 2–0 (configuration).
0x02: The Global Control telegram to synchronize the clock cycles has failed in operation for several consecutive DP clock cycles or in several DP clock cycles has violated the time grid specified using the parameterizing telegram (refer to times Tdp and Tpllw). If the complete DP communications permanently fails, at the latest after the response monitoring times specified when configuring the bus, fault 595 is also output.
Remedy
- Check whether communications is briefly or continuously interrupted.
- Check whether the BUS master can operate in clock cycle synchronism and outputs the global control telegrams, necessary for clock cycle synchronous operation, in the equidistant DP clock cycle.
- Check whether clock synchronism has been activated in the bus configuration, although it is not controlled by the master used.
- Check whether the master sign-of-life is received and incremented in the parameterized clock cycle.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
595Fieldbus: Cyclic data transfer was interrupted
#595Cause
The cyclic data transfer between the master and slave was interrupted due to the fact that cyclic frames were missing, or due to the reception of a parameterizing or configuring frame.
Examples:
- Bus connection interrupted
- Master runs up again
- Master has changed into the ’Clear’ state
For a passive axis, fault cannot be acknowledged using ”RESET FAULT MEMORY”.
Remedy
Check the master and bus connection to the master. As soon as cyclic data transfer runs again, the fault can be acknowledged. Set P0875 to 0 in the passive axis.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
596PROFIBUS: Connection to the publisher \%u interrupted
#596Cause
Cyclic data transfer between this slave and a slave-to-slave communications publisher was interrupted as cyclic telegrams were missing.
Examples:
- Bus connection interrupted
- Publisher failure
- Master runs up again
- The response monitoring (Watchdog) for this slave was de-activated via the parameterizing telegram (SetPrm) (Diagnostics: P1783:1 bit 3 = 0).
Supplementary info: PROFIBUS address of the publisher
Remedy
Check the publisher and bus connections to the publisher, to the master and between the master and publisher. If the watchdog is deactivated, activate the response monitoring for this slave via Drive ES. As soon as cyclic data transfer runs again, the fault can be acknowledged.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
597PROFIBUS: Drive not in synchronism. Supplementary information: \%X
#597Cause
Supplementary information
0x01: The master sign-of-life (STW2, bits 12–15) has more consecutive failures than permitted. The permissible sign-of-life error is specified using P0879 bit 2–0 (PROFIBUS configuration).
0x02: The Global Control Telegram to synchronize the clock cycles in operation has consecutively failed over several consecutive DP clock cycles, or has violated the time grid, specified by the parameterizing telegram (refer to times Tdp and Tpllw) over several consecutive DP clock cycles. If the complete DP communications continuously fails, in addition, fault 599 is output, at the latest after the watchdog monitoring time specified when the bus was configured.
Remedy
- Check whether communications is briefly or continuously interrupted.
- Check whether the PROFIBUS master can operate in clock cycle synchronism and the Global Control Telegrams, required for clock cycle synchronous operation, are output in the equidistant DP clock cycle.
- Check whether clock synchronism has been activated in the bus configuration, although it is not controlled by the master used.
- Check whether the master sign-of-life (STW2, bits 12–15) is received and is incremented in the parameterized clock cycle.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
598PROFIBUS: Synchronization error. Supplementary info: \%X
#598Cause
Supplementary information
0x01: The expected 1st global control clock cycle display did not occur within the waiting time.
0x02: PLL synchronization unsuccessful
0x03: When synchronizing to the clock cycle, the global control clock cycle had more consecutive failures than are permitted.
0x06: The data frames w. the process data (setpoint direction) were only received after the time (To–125us) in the slave has expired.
Remedy
- Check whether the PROFIBUS master can operate in synchronism with the clock cycle, and that the necessary global-control frames are output for operation in synchronism with the clock cycle.
- Check whether clock synchronism has been activated in the bus configuration, although it is not controlled by the master used.
- Check whether the equidistant DP clock cycle, transferred with the parameterizing telegram, was actually set and activated at the master.
- Check whether the time Tdx, defined in the master software, corresponds to the actual data transfer time to all of the slaves and is less than the configured time (To–125us).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
599PROFIBUS: Cyclic data transfer was interrupted
#599Cause
The cyclic data transfer between the master and slave was interrupted due to the fact that cyclic frames were missing, or due to the reception of a parameterizing or configuring frame.
Examples:
- Bus connection interrupted
- Master runs up again
- Master has changed into the ’Clear’ state
For a passive axis, fault cannot be acknowledged using ”RESET FAULT MEMORY”.
Remedy
Check the master and bus connection to the master. As soon as cyclic data transfer runs again, the fault can be acknowledged. Set P0875 to 0 in the passive axis.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II
601Error in AD conversion, terminal 56/14 or 24/20
#601Cause
A timing error was identified when reading-out the A/D converter for terminal 56.x/14.x or 24.x/20.x. The read values are probably incorrect/faulty.
Remedy
Replace closed-loop control module
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
602Open-loop torque controlled oper. w/o encoder is not perm.
#602Cause
In the IM mode, open-loop torque controlled operation was selected via an input terminal or via PROFIBUS-DP or the bus interface.
Remedy
Deselect the torque-controlled operation or leave the IM mode (changeover speed P1465).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
603Changeover to non-parameterized motor data set
#603Cause
An attempt was made to change over to a motor data set which was not parameterized.
Remedy
Parameterizing motor data set
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
604Motor encoder is not adjusted
#604Cause
For an EnDat motor measuring system, it was identified that the serial number does not match that saved, i.e. the encoder has still not run with this drive.
Remedy
1FN3 linear motors (if P1075=1): Measure the rotor position offset to the EMF of the U_R phase and add to P1016 as the commutation angle offset. Then set P1017 to –1 in order to save the serial number of the EnDat encoder. otherwise: To determine commutation angle offset in P1016, initiate the rotor position identification routine via P1017=1. The rotor position identification routine is executed by acknowledging the fault and setting the enable signals.
Note: also refer to description of P1017
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
605Position controller output limited
#605Cause
The speed setpoint requested from the position controller lies above the max. motor speed.
Possible causes:
- Programmed velocity (P0082:64) too high
- Max. acceleration (P0103) or deceleration (P0104) too high
- Axis is overloaded or blocked
Remedy
- Check and correct the above parameter
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
606Flux controller output limited
#606Cause
The specified flux setpoint cannot be realized, although maximum current is input.
- Motor data are incorrect
- Motor data and motor connection type (star/delta) do not match
- Motor has stalled because motor data are extremely inaccurate
- Current limit is too low for the motor (0.9 * P1238 * P1103 < P1136)
- Power section is too small
Remedy
- Correct the motor data
- If required use a larger power section
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
607Current controller output limited
#607Cause
The entered setpoint cannot be impressed in the motor, although the maximum voltage has been entered. The cause could be that the motor is not connected, or a phase is missing.
Remedy
- Check the connecting cable, motor/drive converter (phase missing)
- Check the motor contactor
- DC link voltage present?
- Check the DC link busbar (check that the screws are tight)
- Uce monitoring function in the power section has responded (RESET by powering off/powering on)
- Replace the power section or control module
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
608Speed controller output limited
#608Cause
The speed controller is at its limit for an inadmissibly long time (torque or current limit). The permissible time is defined in P1605, the upper speed limit when the monitoring responds, in P1606.
Synchronous motor: In correct operation, the correctly optimized axis drive should never reach its current limit, not even with large speed changes (changing from rapid traverse in the positive direction to rapid traverse in the negative direction).
P1605 = 200 ms
P1606 = 8000 rev/min
Induction motor: Acceleration and braking with the maximum torque/current are usual in operation, only a stalled drive (0 speed) is monitored.
P1605 = 200 ms
P1606 = 30 rev/min
1. At the first commissioning, after the software has been replaced or the software has been upgraded, after the parameters have been entered the ”calculate motor data” or ”calculate controller data” function was not executed. The drive then keeps the default values (for the values to be calculated this is zero) which can, under certain circumstances, result in this fault (P1605 and P1606 should be adapted to the mechanical and dynamic capabilities of the axis).
2. An undesirable input of a high torque reduction via the analog inputs or via PROFIBUS and the bus interface. For PROFIBUS and the bus interface, this effect especially occurs when changing from the positioning mode to the speed setpoint input mode (check as to whether a torque reduction is entered. Diagnostics using P1717, 0%: No torque, 100%: Full torque).
Remedy
- Check connecting cable motor/converter (phase missing, exchanged)
- Check the motor contactor
- Check the torque reduction (P1717)
- DC link voltage present?
- Check the DC link voltage (check that the screws are tight)
- Unblock the motor
- Is the motor encoder connected?
- Check the motor encoder cable screen
- Is the motor grounded (PE connection)?
- Check the encoder pulse number (P1005)
- Does the encoder cable fit to the encoder type?
- Check the direction of rotation of the encoder tracks (e.g. toothed-wheel encoder, P1011) Adapt parameters P1605 and P1606 to the mechanical and dynamic capabilities of the axis. Check whether a torque reduction has been entered (diagnostics via P1717, 0%: no torque, 100%: full torque).
For linear motors:
- Check actual value inversion
- Check the reduction in the maximum motor current (P1105) and if required increase the value
- Check the power cable connection
- For the parallel circuit configuration, are the motors correctly assigned and electrically connected?
- Uce monitoring function in the power section has responded (RESET by powering off/powering on)
- Replace the power section or control module
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
609Encoder limit frequency exceeded
#609Cause
The speed actual value exceeds the encoder frequency.
- Incorrect encoder
- P1005 does not correspond to the no. of encoder pulses
- Encoder defective
- Motor cable defective or not properly attached
- Shield on motor encoder cable is not connected
- Defective control module
Remedy
- Enter correct encoder data/replace encoder
- Check the encoder pulse number (P1005)
- Attach motor cable correctly or replace
- Connect the motor encoder cable screen
- Reduce the speed setpoint input (P1401)
- Replace control module
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
610Rotor position identification has failed
#610Cause
if P1075=1 (technique based on saturation) A rotor position could not be determined from the measurement signals (motor current), as no significant saturation effects occurred. Also refer to parameter P1734 for detailed diagnostics. if P1075=3 (motion-based technique)
1. Current increase too low.
2. Maximum permissible duration exceeded.
3. No clear rotor position found.
Remedy
if P1075=1
- Increase current via P1019
- Check armature inductance (P1116) and if required, increase
- Check the connecting cable, motor/drive converter (phase missing)
- Check the motor contactor
- DC link voltage present?
- Check the DC link busbar (check that the screws are tight)
- Uce monitoring function in the power section has responded (RESET by powering off/powering on)
- Replace the power section or control module if P1075=3 To 1.
- The motor is not correctly connected
- The motor power connection must be checked To 2.
- Remove disturbing external forces (e.g. axis couplings which are not released)
- Identification technique must remain stable (P1076 must be reduced)
- Use an encoder with higher resolution
- Improve the encoder mounting (it is not stiff enough) To 3.
- Remove disturbing external forces (e.g. axis couplings which are not released)
- The axis must be able to freely move (e.g. the motor rotor may not be locked)
- Reduce the high axis friction (increase P1019)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
611Illegal motion during rotor position identification
#611Cause
During the rotor position identification (motor current measurement), the motor rotated more than the value entered in P1020. The rotation could be caused by having powered on with the motor already rotating, or caused by the identification routine itself.
Remedy
if P1075=1
- If the interchange was caused by the identification itself and if the error occurs again, then reduce P1019 or increase P1020.
- Lock the motor rotor during the identification routine. if P1075=3
- Increase the parameterized load mass (P1076)
- Check the maximum permissible motion (P1020) and if required, increase
- Reduce the current, rotor position identification (P1019) If the current and speed controller clock cycle have low values (62.5 microseconds), then it maybe necessary to increase P1019.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
612Illegal current during rotor position identification
#612Cause
1. Current was >= 1.2 * 1.05 * P1107 while rotor position identification was active
2. Current was >= P1104 while rotor position identification was active
Remedy
With the rotor position identification (P1011.12 and P1011.13) activated, if required, check and reduce P1019 (current, rotor position identification)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
613Shutdown limit, motor overtemperature (P1607) exceeded
#613Cause
The motor temperature (sensed via the temperature sensor KTY 84 and fed to the module via the motor encoder cable) has exceeded the temperature limit in P1607.
Remedy
- Avoid many acceleration and braking operations which follow one another quickly.
- Motor overload?
- Check whether the motor output is sufficient for the drive, otherwise use a more powerful motor, possibly together with a higher-rating power section.
- Check the motor data. The current could be too high due to incorrect motor data.
- Check the temperature sensor.
- Check the motor fan.
- Check the motor encoder cable.
- Motor encoder defective?
- Check and possibly reduce P1230 or P1235. The motor temperature monitoring can be disabled with P1601 bit 13 = 1.
For linear motors:
- Check the parameters for the motor temperature monitoring P1602 (alarm threshold, motor overtemperature) = 120 degrees C P1603 (timer, motor temperature alarm) = 240 s P1607 (shutdown limit, motor temperature) = 155 degrees C P1608 (fixed temperature) = 0 degrees C
P1608 = 0 ––> Temperature sensing active
P1608 > 0 ––> Fixed temperature active
- If the temperature monitoring is exclusively realized using an external PLC, a fixed temperature must be entered into P1608 (e. g. 80 degrees C). This disables the drive temperature monitoring.
- Check the power connector at the motor
- Check the connection of the temperature sensor coupling cable at the end of the power cable; approximately 580 ohm must be measured at 20 degrees C
- With the measuring system connector withdrawn (X411 for 611U or MOT ENCODR for POSMO), is approx. 580 Ohm at 20 Degrees C measured between PIN 13 (611U) or 20 (POSMO) and PIN 25 (611U) or 21 (POSMO) of the encoder cable?
- Check the measuring system connector at the drive (X411 or MOT ENCODR) to ensure that it is correctly inserted
- Only KTY may be connected for drives connected in parallel
- If the temperature switch and temperature sensor are connected in series, the temperature sensor (NC contact) may have responded, or the temperature switch is defective
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
614Delayed shutdown for motor overtemperature (P1602/P1603)
#614Cause
The motor temperature (sensed via the temperature sensor KTY 84 and fed to the module via the motor encoder cable) has exceeded the temperature in P1602 for a time longer than in P1603.
Remedy
- Avoid many acceleration and braking operations which follow one another quickly.
- Motor overload?
- Check whether the motor output is sufficient for the drive, otherwise use a more powerful motor, possibly together with a higher-rating power section.
- Check the motor data. The current could be too high due to incorrect motor data.
- Check the temperature sensor.
- Check the motor fan.
- Check the motor encoder cable.
- Motor encoder defective?
- Check and possibly reduce P1230 or P1235. The motor temperature monitoring can be disabled with P1601 bit 14 = 1.
For linear motors:
- Check the parameters for the motor temperature monitoring P1602 (alarm threshold, motor overtemperature) = 120 degrees C P1603 (timer, motor temperature alarm) = 240 s P1607 (shutdown limit, motor temperature) = 155 degrees C P1608 (fixed temperature) = 0 degrees C
P1608 = 0 temperature sensing active
P1608 > 0 fixed temperature active
- If the temperature monitoring is exclusively realized using an external PLC, a fixed temperature must be entered into P1608 (e. g. 80 degrees C). This disables the drive temperature monitoring.
- Check the power connector at the motor
- Check the connection of the temperature sensor coupling cable at the end of the power cable; approximately 580 ohm must be measured at 20 degrees C
- With the measuring system connector withdrawn (X411 for 611U or MOT ENCODR for POSMO), is approx. 580 Ohm at 20 Degrees C measured between PIN 13 (611U) or 20 (POSMO) and PIN 25 (611U) or 21 (POSMO) of the encoder cable?
- Check the measuring system connector at the drive (X411 or MOT ENCODR) to ensure that it is correctly inserted
- Only KTY may be connected for drives connected in parallel
- If the temperature switch and temperature sensor are connected in series, the temperature sensor (NC contact) may have responded, or the temperature switch is defective
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
615DM encoder limiting frequency exceeded
#615Cause
The speed actual value of the direct measuring system exceeds the permissible encoder limiting frequency.
- Incorrect encoder
- P1007 does not coincide with the encoder pulse number
- Encoder defective
- Defective encoder cable or not correctly retained
- Encoder cable shield is not connected
- Defective control module
Remedy
- Enter correct encoder data/replace encoder
- Check encoder pulse number (P1007)
- Correctly retain encoder cable/replace
- Connect encoder cable shield
- Reduce speed setpoint input
- Replace control module
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
616DC link undervoltage
#616Cause
The DC link voltage has exceeded the permissible lower limit P1162.
Remedy
- Check whether the line supply voltage is available
- Check whether the pulsed resistor is overloaded
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
617DC link overvoltage
#617Cause
The DC link voltage has exceeded the permissible upper limit P1163.
Remedy
- Check whether the line supply voltage is available
- Reduce load duty cycle
- Check P1163
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- parameterizable
680Illegal motor code number
#680Cause
A motor code was entered in P1102 for which no data is available.
Remedy
- Commission the system again and enter the correct motor code number (P1102).
- The ”SimoCom U” parameterizing and start-up tool includes motors that are still not known in this particular drive version. Either upgrade the drive version or enter the motor as non-listed motor.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
681Illegal power section code number
#681Cause
A power section code was entered in P1106, for which no data is available.
Remedy
- Enter the correct power module code into P1106.
- For power modules with automatic identification, upgrade firmware.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
682Illegal encoder code number in P\%u
#682Cause
An encoder code was entered in P1006 or P1036, for which there is no data. The direct measuring system (P0250/P0879.12) is activated, although an encoder was not specified in P1036.
Remedy
Enter the correct encoder code or the code for third-party encoders (99) in P1006 or P1036. De-activate direct measuring system (P0250/P0879.12).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
683Calculate controller data was unsuccessful at first start-up (\%d)
#683Cause
An error occurred at the first start-up with ”calculate controller data”. Under fault conditions, the parameters for the current controller, flux controller and speed controller could not be optimally assigned.
Remedy
Read out the detailed error cause from P1080 and remove the cause. Then initiate ”calculate controller data” again with P1080 = 1. Repeat this operation, until no error is displayed in P1080. Then save in the FEPROM and execute a POWER ON-RESET. Error coding in the supplementary info and P1080: –15 magnetizing reactance (P1141) = 0 –16 leakage reactance (P1139/P1140) = 0 –17 rated motor frequency (P1134) = 0 –18 rotor resistance (P1138) = 0 –19 motor moment of inertia (P1117) = 0 –21 threshold speed for field weakening (P1142) = 0 –22 motor standstill current (P1118) = 0 –23 The ratio between the maximum motor current (P1104) and the motor stall current (P1118) is greater than the maximum value for the torque limit (P1230) and the power limit (P1235). –24 The ratio between the rated motor frequency (P1134) and the rated motor speed (P1400) is inadmissible (pole pair number).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
703Invalid current controller cycle
#703Cause
An illegal value was entered in P1000.
Remedy
Enter a valid value in P1000. Permissible values for P1000 are: 2 (62.5 µs) for single-axis positioning or for speed setpoint input 4 (125 µs) in each operating mode
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
704Invalid speed controller cycle
#704Cause
An illegal value was entered in P1001.
Remedy
Enter a valid value in P1001. Permissible values for P1001 are 2 (62.5 µs), 4 (125 µs), 8 (250 µs), 16 (500 µs). Setting 2 (62.5 µs) is only permissible for single-axis operation. Further, P1001 must be >= P1000.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
705Invalid position controller cycle
#705Cause
The monitoring function identified a position controller cycle (P1009) outside the permissible limits.
Remedy
Enter a valid value in P1009. Permissible values for P1009 lie between 32 (1 ms) and 128 (4 ms). Further, the position control cycle must be a integral multiple of the speed control cycle.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
706Invalid interpolation cycle
#706Cause
The monitoring has identified an interpolation cycle (P1010) outside the permissible limits, or an illegal ratio between the interpolation cycle and the position controller cycle (P1009).
Remedy
Enter a valid value in P1010 or correct P1009. Permissible values for P1010 lie between 128 (4ms) and 640 (20 ms) or, only for the 1-axis version, also 64 (2ms) if P1009 is also 64 (2 ms). Further, the interpolation cycle must be an integral multiple of the position controller cycle.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
708Axial deviations in current controller cycle
#708Cause
On a 2-axis module, the current controller cycle is different for both axes.
Remedy
Check P1000 and set the input values the same for both drives.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
709Axial deviations in speed controller cycle
#709Cause
On a 2-axis module, the speed controller cycle is different for both axes.
Remedy
Check P1001 and set the input values the same for both drives.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
710Axial deviations in position controller or interpolation cycle
#710Cause
For a 2-axis module, the position controller clock cycle (P1009) or the interpolation clock cycle (P1010) is different for the two axes.
Remedy
Check P1009/P1010 and set the input values for both drives the same.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
716Invalid torque constant
#716Cause
The ratio between the rated torque and rated current (torque constant [Nm/A]) in P1113 is incorrect (less than/equal to zero) or the ratio P1113/P1112 is greater than 70.
Remedy
Enter the valid torque/current ratio for the motor used in P1113 or enter a permissible ratio of P1113/P1112. Third-party motor: The torque constant should be determined from the motor data sheet. Siemens motor: The torque constant is defined by the motor code (P1102).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
719Motor not parameterized for delta operation
#719Cause
When the star-delta changeover is activated using P1013, the motor is not parameterized for delta operation (motor 2).
Remedy
Check and enter the parameters for delta operation (motor 2).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
720Invalid maximum motor speed
#720Cause
Due to the high maximum motor speed in P1401 and the speed controller cycle in P1001, high partial speeds can occur which can result in a format overflow.
Remedy
Check and correct P1401 and P1001. The drive software is designed for large reserve margins, so that the displayed alarm can only occur as a result of a parameterizing error. Example:
For a speed controller cycle time of 125 microseconds, a motor speed of 480 000 RPM can still be processed correctly!
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
721Spindle speed too high
#721Cause
As a result of the high spindle speed and the interpolation clock cycle (P1010), the modulo value can no longer be correctly taken into account. The alarm is initiated, if jerky equalization motion occurs – e.g. due to incorrect parameter values.
Remedy
Shorten the interpolation clock cycle. If possible, increase the modulo range of the rotary axis (P0242). Calculating the spindle speed limit [RPM] = 7 / IPO clock cycle[ms] x 60 x 1000 (for the modulo range, 360 degrees = 1 spindle revolution) Example: IPO clock cycle = 4 ms, for max. 7 revolutions (up to 7 x modulo range)
- a maximum spindle speed of 105000 RPM is obtained per IPO clock cycle.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
722Changeover speed/velocity too low
#722Cause
For the selected setting of P1466, the induced voltage is too low in the lower speed range in order to be able to reliably guarantee sensorless operation. The induced voltage must be at least 40 Volt (phase-to-phase, RMS) at the particular speed.
Remedy
The following should be ensured: Induction motor : P1466 >= 150 U/min Rotary synchronous motor: P1466 > 40000 / P1114 Linear motor: P1466 > 1386 / P1114
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
723Axial deviations in STS configuration
#723Cause
On a 2-axis module, the gating unit configuration (P1003) is different for the two gating units.
Remedy
Check P1003 and set the bits for the two module axes the same (do not change the standard setting, this represents the optimum configuration).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
724Invalid motor pole pair number
#724Cause
Synchronous motors:
- The pole pair number in P1112 is zero or negative.
- Encoder with CD track (P1027.6 = 0): The pole pair number in P1112 is greater than 6.
- Encoder without CD track or with Hall sensors (P1027.6 = 1): The motor pole pair number is dependent on the encoder pulse number (max. 4096 for P1005 >= 32768). Induction motors:
- An invalid pole pair number was determined from P1134 and P1400. Motor with resolver:
- The maximum motor pole pair number for the modules 6SN1118–*NK01–0AA0 or 6SN1118–*NJ01–0AA0 is 64, otherwise 4 or 6.
Remedy
Synchronous motors:
- Check P1112, P1027 and P1014. Induction motors:
- Determine and correctly enter rated speed and/or rated frequency.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
725Invalid encoder pulse number
#725Cause
The encoder pulse number of the motor measuring system (P1005) is set to zero.
Remedy
Harmonize the encoder pulse number of the motor measuring system in P1005 to the encoder used. The indirect motor measuring system must always be configured for synchronous and induction motors (exception: Induction motor operation). Standard setting: 2 048 increments/revolution
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
726Invalid voltage constant
#726Cause
The voltage constant of the motor in P1114 is set to zero.
Remedy
Determine the voltage constant of the motor used, and enter in P1114. The voltage constant is measured as induced voltage (EMF) under no-load conditions at n = 1 000 RPM as RMS valued at the motor terminals (phase to phase). Third-party motor: The voltage constant should be determined from a motor data sheet. Siemens motor: The voltage constant is determined from the motor code (P1102).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
727Invalid combination of power section and synchronous motor
#727Cause
The power module has not been released for synchronous motors.
Remedy
- Check configuring
- Use a valid power section
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
728Torque/current adaptation factor too high
#728Cause
The adaptation factor between the setpoint torque and the torque generating current (Iq) in the speed controller is too high.
Remedy
Check P1103, P1107 and P1113 and if required, enter correct values. Third-party motor: The values should be determined from a motor data sheet. Siemens motor: The values are determined from the motor code (P1102).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
729Invalid motor stall current
#729Cause
The motor stall current (P1118) is less than or equal to zero.
Remedy
Determine the stall current of the motor used and enter in P1118. Third-party motor: The stall current should be determined from a motor data sheet. Siemens motor: The stall current is determined from the motor code (P1102).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
731Invalid rated output
#731Cause
The rated motor output (P1130) of the motor is less than or equal to zero.
Remedy
Determine the rated motor output of the motor used and enter in P1130. Third-party motor: The rated motor output should be determined from a motor data sheet. Siemens motor: The rated motor output is determined from the motor code (P1102).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
732Invalid rated speed
#732Cause
The rated motor speed (P1400) of the motor is less than or equal to zero.
Remedy
Determine the rated motor speed of the motor used and enter in P1400. Third-party motor: The rated motor speed should be determined from a motor data sheet. Siemens motor: The rated motor speed is determined from the motor code (P1102).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
738Incorrect mode, analog input for the equalization controller
#738Cause
If the equalization controller is parameterized with P1490 = 1 –> then P0612 must be parameterized with the value 3
Remedy
- P0612=3 or
- P1490 not equal to 1
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
739Incorrect axis number, equalization controller
#739Cause
If the equalization controller is parameterized with P1490 = 2 –> two active axes must be available on the module.
Remedy
- P1490 equal to 1 (coupling via analog terminals) or
- Activate the 2nd axis or
- Use a 2-axis module
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
742V/f operation: Drive frequency, motor \%d not permissible
#742Cause
In V/f operation, only drive converter frequencies of 4 or 8 kHz are permissible.
Remedy
Change P100 or cancel V/f operation (P1014). When operating with several motors/motor data sets, also set P2100/P3100/P4100 to 4 or 8 kHz.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
743Function is not possible using this control board
#743Cause
”
Remedy
”
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
744Motor changeover only permissible for the closed-loop speed controlled mode
#744Cause
Motor changeover (P1013) may only be activated in the closed-loop speed controlled mode (P0700 = 1).
Remedy
- Inhibit motor changeover (P1013 = 0)
- Change over into the closed-loop speed controlled mode (P0700 = 1)
- Acknowledgement
- POWER ON
- Stop response
- STOP I
749Speed measuring range is not sufficient
#749Cause
The maximum speed which can be achieved with speed feedback cannot be measured using the module.
Remedy
- Parameterize the encoder type corresponding to the type of motor and the control module.
- Synchronous motor: P1147 * resolver pole pair number must be less than the limiting frequency of the control module (12 bit: 25402 RPM; 14 bit: 6350 RPM).
- Induction motor : min (P1146, P1465) * resolver pole pair number must be less than the limiting frequency of the control module (12 bit: 25402 RPM; 14 bit: 6350 RPM).
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
751Speed controller gain too high
#751Cause
P gain, speed controller for the lower speed range (P1407) and the upper speed range (1408) were selected to be too high.
Remedy
Reduce the P gain of the speed controller. Only optimized with the adaption disabled (P1413 = 0). The P gain (P1407) is then effective over the complete speed range. After the optimum setting has been found, adaption can be re-enabled (P1413 = 1) and the P gain optimized for the upper speed range (P1408).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
753Current, rotor position identification less than the min. value
#753Cause
A current was parameterized in P1019 (current, rotor position identification) which is less than the minimum value permissible for the motor.
Remedy
Enter a current in P1019, which is not less than the permissible minimum value for the motor (40% for third-party synchronous linear motor). It may be necessary to use a larger power module. If permissible for the motor used, suppress the fault by setting P1012, bit 5. Caution:
For motors with weak saturation effects (e.g. 1FN3 linear motors), as a result of the low identification current, orientation may be erroneous, thus resulting in uncontrolled motion.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
756Invalid speed hysteresis of the current setpoint smoothing
#756Cause
The hysteresis of the speed for the current setpoint smoothing (P1246) may not be greater than the threshold speed of the hysteresis (P1245), as otherwise a ”negative” lower speed would be obtained.
Remedy
P1246 (standard value: 50 [RPM]) must be entered lower than the threshold for the speeddependent setpoint smoothing (P1245, standard value: 4 000 [RPM]).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
757PZD config.: illegal frame no. in P0922
#757Cause
The frame number set in P0922 is illegal or impermissible for the operating mode currently selected via P0700.
Remedy
Check P0922 and enter valid value.
- Acknowledgement
- POWER ON
- Stop response
- STOP II
758Setpoint source incorrectly parameterized. Supplementary info \%u
#758Cause
The selected setpoint source in P0891 is invalid. 1 Internal coupling not possible for POSMO or single-axis module 2 Internal coupling not possible for drive A 3 Coupling via PROFIBUS-DP or the bus interface selected, but the matching option module is not inserted
Remedy
Check P891 and enter a valid value.
- Acknowledgement
- POWER ON
- Stop response
- STOP II
759Encoder/motor types do not match
#759Cause
A linear motor was selected, and no linear scale configured (P1027.4 = 0). A rotating motor was selected and a linear scale configured (P1027.4 = 1). A resolver has been selected the pole pair number (P1018) of which is illegal. A pole pair number =1 or the pole pair number of the motor (P1112) is admissible. The maximum speed (P1146) cannot be measured with the resolver. The required resolution (1011[2] = 1 or 1030[2] = 1, resolver evaluation) cannot be set using this module.
For this setting, either 6SN1118–*NK01–0AA0 or 6SN1118–*NJ01–0AA0 is required.
Remedy
- Parameterize the encoder type corresponding to the type of motor and the control module.
- Use the required (6SN1118–*NK01–0AA0 or 6SN1118–*NJ01–0AA0) control module.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
760Pole pair width/scale graduations cannot be represented internally
#760Cause
For linear motors, the equivalent (internal) pole pair number and (internal) encoder pulse number are calculated from the pole pair width and grid division. In this case, the encoder pulse number must be an integer multiple of one or x pole pair widths. This error message is output if the pole pair width/grid division * x (up to x=4096) is not an integer multiple or if an internal encoder pulse number which was calculated is too high. A result with a tolerance of +/– 0.001 absolute is interpreted to be an integer.
Remedy
Long travel paths: A linear measuring system with an encoder mark number that is an integral divisor of x* pole pair widths should be used. Short travel paths:
For short travel, only a low error can accumulate which has hardly any effect on the maximum achievable force and on the temperature rise, if the encoder pulse number fits with a deviation of more than +/–0.001 in the pole pair width. We then recommend that the pole pair width is slightly changed.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
761P0892 cannot be used with this measuring system
#761Cause
The following settings are permitted (Order No.[MLFB] 6SN1118–....): Incremental measuring systems (7 bit) with sin/cos 1 Vpp without EnDat interface (..*NH00–0AA*, ..*NH10–0AA*) : 0 Incremental measuring systems (7 bits) with sin/cos 1 Vpp with EnDat interface (..*NH00–0AA*, ..*NH10–0AA*) : 0,1,2,3 Incremental measuring systems (11 bit) with sin/cos 1 Vpp (..*NH01–0AA*, ..*NH11–0AA*) : 0,1,2,3,4 resolver (12 bit) (..*NK00–0AA0 or ..*NJ00–0AA0) : 0,1,2,3 Resolver (12 bit) (..*NK01–0AA0 or ..*NJ01–0AA0) with 12-bit resolution (1011[2] = 0 or 1030[2] = 0) : 0,1,2,3,4,5 Resolver (14 bit) (..*NK01–0AA0 or ..*NJ01–0AA0) with 14-bit resolution (1011[2] = 1 or 1030[2] = 1) : –2,–1,0,1,2,3
Remedy
Set P0892 (factor, angular encoder pulse number/encoder pulse number) to a valid value.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
762P0893 cannot be used with this measuring system
#762Cause
For incremental measuring systems with sin/cos 1 Vpp without EnDat interface and for linear measuring systems with sin/cos 1 Vpp with EnDat interface, a zero pulse offset cannot be set via P0893.
Remedy
Set P0893 (angular encoder zero pulse offset) to 0.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
764Multiple assignment of terminal A or B (P0890)
#764Cause
When selecting 3 in P0890, from drive A or B (setpoint at terminal A and actual value at terminal B), it was identified, that terminal A or B were already being used by another drive. Thus, this configuration is not possible.
Remedy
Check the configuration of terminals A and B in P0890 and eliminate multiple assignments of both drives.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
765P0890 and P0891 configure both setpoint inputs
#765Cause
An actual value coupling is switched in (P0891 = 1) for drive B. Simultaneously, for the same drive, terminal A or B is parameterized as position setpoint input (P0890 = 2 or 3).
Remedy
Check the configuration of terminals A and B in P0890, compare with P0891 and eliminate multiple setpoint sources.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
766Blocking frequency > Shannon frequency
#766Cause
The bandstop frequency of a speed setpoint filter is greater than the Shannon sampling frequency from the sampling theorem.
Remedy
The bandstop frequency for P1514, filter 1 or P1517 for filter 2 must be less than the inverse value of two speed controller clock cycles 1/ (2 * P1001 * 31.23 microseconds).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
767Natural frequency > Shannon frequency
#767Cause
The natural frequency of a speed setpoint filter is greater than the Shannon sampling frequency from the sampling theorem.
Remedy
The natural frequency of a speed setpoint filter must be lower than the reciprocal of two speed controller cycles. Speed setpoint filter 1: P1520 * 0.01 * P1514 < 1 / (2 * P1001 * 31.25 microseconds) Speed setpoint filter 2: P1521 * 0.01 * P1517 < 1 / (2 * P1001 * 31.25 microseconds)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
768Numerator bandwidth > twice the blocking frequency
#768Cause
The numerator bandwidth of a current or speed setpoint filter is greater than twice the bandstop frequency. This alarm is only generated for the general bandstop, if the following is valid: Speed setpoint filter 1: P1516 > 2 * P1514 or P1520 <> 100.0 Speed setpoint filter 2: P1519 > 0.0 or P1521 <> 100.0 Current setpoint filter 1: P1212 > 0.0 Current setpoint filter 2: P1215 > 0.0 Current setpoint filter 3: P1218 > 0.0 Current setpoint filter 4: P1221 > 0.0
Remedy
The numerator bandwidth must be less than twice the bandstop frequency. Current setpoint filter 1: P1212 <= 2 * P1210 Current setpoint filter 2: P1215 <= 2 * P1213 Current setpoint filter 3: P1218 <= 2 * P1216 Current setpoint filter 4: P1221 <= 2 * P1219 Speed setpoint filter 1: P1516 <= 2 * P1514 Speed setpoint filter 2: P1519 <= 2 * P1517
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
769Denominator bandwidth > twice the natural frequency
#769Cause
The denominator bandwidth of a current or speed setpoint filter is greater than twice the natural frequency. This alarm is only generated for the general bandstop, if the following is valid: Speed setpoint filter 1: P1516 > 2 * P1514 or P1520 <> 100.0 Speed setpoint filter 2: P1519 > 0.0 or P1521 <> 100.0 Current setpoint filter 1: P1212 > 0.0 Current setpoint filter 2: P1215 > 0.0 Current setpoint filter 3: P1218 > 0.0 Current setpoint filter 4: P1221 > 0.0
Remedy
The denominator bandwidth of a current or speed setpoint filter must be less than twice the natural frequency. Speed setpoint filter 1: P1515 <= 2 * P1514 * 0.01 * P1520 Speed setpoint filter 2: P1518 <= 2 * P1517 * 0.01 * P1521 Current setpoint filter 1: P1211 <= 2 * P1210 Current setpoint filter 2: P1214 <= 2 * P1213 Current setpoint filter 3: P1217 <= 2 * P1216 Current setpoint filter 4: P1220 <= 2 * P1219
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
770Format error
#770Cause
The calculated bandstop filter coefficients cannot be represented in the internal format.
Remedy
Change filter setting.
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
771Induction motor oper.: drive converter frequency motor \%d not permissible
#771Cause
In induction motor operation (selected by P1465 < P1146), drive converter frequencies of 4 or 8 kHz are permissible.
Remedy
- Change P1100
- Cancel induction motor operation (P1465 > P1146)
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
772Induction motor oper.: speed controller gain, motor \%d too high
#772Cause
The P gain of the speed controller (P1451) is too high.
Remedy
For the speed controller, enter a lower value for the P gain (P1451).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
773Not permissible to active analog input
#773Cause
For this particular hardware version, it is not permissible to activate the analog input.
Remedy
- Set P0607 to 0 and P0612 to 0 or
- Use the ”SIMODRIVE 611 universal” control module.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
774Induction motor oper.: changeover speed motor \%d not permissible
#774Cause
For mixed operation (with/without encoder) P1465 > 0, only closed-loop controlled induction motor operation is permissible (P1466 <= P1465).
Remedy
Eliminate error by selecting pure induction motor operation (P1465 = 0) or by canceling induction motor open-loop controlled operation (P1465 > P1466).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
775SSI encoder incorrectly parameterized. Supplementary info \%u
#775Cause
Incorrect parameterization of the SSI absolute value encoder.
Supplementary info = 0x1, 0x11 (indirect, direct measuring system): ––> The single-turn resolution cannot be 0.
Supplementary info = 0x2, 0x12 (indirect, direct measuring system): ––> The number of parameterized bits is greater than the telegram length.
Supplementary info = 0x3, 0x13 (indirect, direct measuring system): ––> For linear encoders, it is not possible to have multi-turn resolution.
Remedy
For supplementary info 1 or 11: Check P1022 and P1032
For supplementary info 2 or 12: Check P1021, P1022, P1027.12 and P1027.14 with respect to P1028 and check P1031, P1032, P1037.12 and P1037.14 with respect to P1041
For supplementary info 3 or 13: Check P1021 and P1031
- Acknowledgement
- POWER ON
- Stop response
- STOP I
776TTL encoder not possible for older basic module
#776Cause
For an old basic module, which does not support TTL encoders, a TTL encoder was selected as motor measuring system.
Remedy
Use a new basic module or incremental measuring system with sin/cos 1 Vpp.
- Acknowledgement
- POWER ON
- Stop response
- STOP I
777Current for the rotor position identification too high
#777Cause
A current was parameterized in P1019, which is greater than the current which is permissible for the motor and the power section used.
Remedy
Reduce the current via P1019.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
778Impermissible converter frequency for rotor position ID
#778Cause
When selecting the rotor position identification (P1019), drive converter frequencies (P1100) of 4 or 8 kHz are permissible.
Remedy
Change the drive converter frequency or cancel the rotor position identification.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
779Motor moment of inertia, motor \%d invalid
#779Cause
The motor moment of inertia (P1117) is incorrect (less than/equal to zero).
Remedy
Enter the valid motor moment of inertia for the motor used, in P1117. Third-party motor: The motor moment of inertia should be determined from a motor data sheet. Siemens motor: The characteristic motor data should be determined from the motor code (P1102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
780No-load current, motor > rated motor current (motor \%d)
#780Cause
The motor no-load current (P1136) has been parameterized greater than the rated motor current (P1103).
Remedy
Enter the valid currents for the motor used in P1136 and P1103. Third-party motor: The required currents should be determined using a motor data sheet. Siemens motor: The currents are determined using the motor code (P1102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
781No-load current, motor \%d > rated power section current
#781Cause
The motor no-load current (P1136) has been set to higher values than the rated power section current. before SW 2.4 the following is valid: Rated power section current = P1111 from SW 2.4 the following is valid: Rated power section current = P1111 * P1099
Remedy
- Enter the valid current for the motor used in P1136. Third-party motor: The required currents should be determined using a motor data sheet. Siemens motor: The currents are determined using the motor code (P1102).
- Reduce the power section pulse frequency P1100.
- Use a higher-rating power section (re-commission).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
782Reactance motor \%d invalid
#782Cause
The stator leakage reactance (P1139) or the rotor leakage reactance (P1140) or the magnetizing reactance (P1141) of the motor is incorrect (less than/equal to zero).
Remedy
Determine the stator, rotor leakage reactance and magnetizing reactance of the motor used and enter in P1139, P1140 and P1141. Third-party motor: The values should be determined from a motor data sheet. Siemens motor: The values are determined from the motor code (P1102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
783Rotor resistance, motor \%d invalid
#783Cause
The rotor resistance (P1138, cold) of the motor is zero or there was a format overflow for an internal conversion.
Remedy
The following parameters can have incorrect values: P1001 (speed controller cycle) P1134 (rated motor frequency) P1138 (rotor resistance) P1139 (leakage stator reactance) P1140 (leakage rotor reactance) P1141 (magnetizing field reactance) Check the parameter, and if required, correct using the motor data sheet. The following condition must be fulfilled: 16 * P1001 * 0.00003125 * P1138 * 2PI * P1134 / (P1140 + P1141) < 1
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
784No-load voltage, motor \%d invalid
#784Cause
Error in no-load voltage P1135:
- P1135 <= 0 or
- P1135 > P1132 or
- P1135 * P1142 / P1400 + Vser.react. > 450V. With Vser.react. = 0.181 * P1136 * P1142 * P1119
Remedy
Determine the no-load voltage of the installed motor and enter this in P1135. Third-party motor: The following parameters may have incorrect values: P1119 (inductance of the series reactor) P1132 (rated motor voltage) P1135 (no-load motor voltage) P1400 (rated motor speed) P1142 (threshold speed for field weakening) P1136 (no-load motor current) Check parameters and if required correct using a motor data sheet. Siemens motor: The no-load voltage is determined from the motor code (P1102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
785No-load current, motor \%d invalid
#785Cause
The no-load current (P1136) of the motor (ARM) is incorrect (less than/ equal to zero).
Remedy
Determine the no-load current of the motor used (ARM) and enter into P1136. Third-party motor: The no-load current should be determined from a motor data sheet. Siemens motor: The no-load current is determined from the motor code (P1102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
786Field-weakening speed, motor \%d invalid
#786Cause
The threshold speed for field weakening for induction motors (P1142) is incorrect (less than/equal to zero).
Remedy
Determine the threshold speed for field weakening for the motor used and enter in P1142. Third-party motor: The field weakening speed should be determined from a motor data sheet. Siemens motor: The field weakening speed is determined from the motor code (P1102).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
787Induction motor oper.: feedforward control gain motor \%d cannot be displayed
#787Cause
The feedforward control gain for induction motors cannot be represented in the internal numerical format if the motor moment of inertia and rated motor torque were unfavorably selected.
Remedy
Operation without encoder: Reduce the encoder pulse number (P1005), as this is used in the internal numerical format. Operation with encoder: Reduce the speed controller cycle (P1001).
- Acknowledgement
- RESET FAULT MEMORY
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
788P0891 for drive B only
#788Cause
An actual-value link has been activated (P0891 = 1) for drive A. The hardware does not permit this setting.
Remedy
Set P0891 to 0 for drive A.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
789Setpoint transfer SimoCom U ==> drive interrupted
#789Cause
The setpoint transfer from SimoCom U to the drive was interrupted, i.e. there is no longer an online connection. The Master Control was returned to the drive. Communication between the two communication partners was faulty. When traversing the drive via SimoCom U, other functions were executed on the PG/PC (e.g. open online help, open file), so that the drive can only be irregularly supplied from SimoCom U.
Remedy
- Check whether SimoCom U is still operating correctly, if required, restart
- Check whether the communication connection is OK, if required, replace the connecting cable
- When in the online mode, do not select any time-intensive functions
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
790Illegal operating mode. Supplementary info: \%u
#790Cause
The selected operating mode (P0700) is not permitted for this module or axis.
Supplementary info = 0x1: Operating mode ==0 selected on the 1st axis
Supplementary info = 0x2: ”Positioing” operating mode selected for the Nset control module
Supplementary info = 0x3: Operating mode is not possible with this firmware release
Supplementary info = ”External position reference value” operating mode no longer possible.
Remedy
For supplementary info 1: Select valid operating mode (P0700 > 0)
For supplementary info 2: Select Nset operating mode or use a positioning module.
For supplementary info 3: Use a firmware release which supports this operating mode.
For supplementary info 4: Select ”Positioning” operating mode.
- Acknowledgement
- POWER ON
- Stop response
- STOP I
791TTL encoder interface incorrectly parameterized
#791Cause
The TTL encoder interface may only be parameterized as follows for this particular hardware version: Drive A: P0890 = 0 or 4, 0: Interface inactive, 4: TTL encoder input Drive B: P0890 = 0
Remedy
Set P0890 to permissible value.
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
792Direct measuring system incorrectly parameterized. Supplementary info: \%u
#792Cause
It is not permitted to parameterize the direct measuring system.
Supplementary info = 0x1: A direct measuring system cannot be used using this board.
Supplementary info = 0x2: The direct measuring system cannot be simultaneously operated with drive B.
Supplementary info = 0x3: The direct measuring system is active and drive A is set for encoderless operation (P1027 bit 5 = 1).
Remedy
For supplementary info 1: Use the required board.
For supplementary info 2:
- De-activate the direct measuring system for drive A (P0250/P0879.12 = 0) or
- Switch drive B inactive (P0700 = 0)
For supplementary info 3:
- De-activate the direct measuring system for drive A (P0250/P0879.12 = 0) or
- Commission the motor measuring system for drive A
- Acknowledgement
- POWER ON
- Stop response
- STOP I
793Angular encoder signal waveform different for drive A and B
#793Cause
The input signal waveform for the angular encoder interface must be set the same for the drives.
Remedy
Check P0894 for both drives and set the same
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
794P0890 = 3 not permitted for drive B
#794Cause
This angular encoder interface setting is not permitted for drive B.
Remedy
Check P0890 for drive B and set to a permissible value
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
795Ang. encoder, pos. ref. value normalization factor too large. Suppl. info: \%u
#795Cause
The position reference value normalization for the angular encoder interface is not permissible.
Supplementary info = 1 ––> Condition P0401 * P0895 < 8388608 violated = 2 ––> Condition P0402 * P0896 < 8388608 violated
Remedy
Check parameterization via P0401, P0402, P0895 and P0896. It may be possible to achieve the conditions above by shortening the numerator P0401 * P0895 with the denominator P0402 * P0896.
- Acknowledgement
- POWER ON
- Stop response
- STOP II
797Error in center frequency measurement
#797Cause
The speed was too high during the center frequency measurement (current calibration). The center frequency is measured automatically at run-up, or when the pulses are inhibited.
Remedy
Power up the drive converter if the motor runs at a reduced speed.
- Acknowledgement
- POWER ON
- Stop response
- STOP I
798Measured value memory active
#798Cause
The measured-value memory was active during power-up.
Remedy
Run up again.
- Acknowledgement
- POWER ON
- Stop response
- STOP I
799FEPROM backup and HW Reset required
#799Cause
Parameters were re-calculated. Parameters must be saved and the module run up again after this new calculation.
Remedy
The newly calculated data should be saved in the FEPROM. The new parameters become effective the next time that the module runs up!
- Acknowledgement
- POWER ON
- Stop response
- STOP II (SRM, SLM) STOP I (ARM)
800Minus hardware limit switch
#800Cause
A 1/0 edge was identified at the ”Minus hardware limit switch” input signal.
Remedy
- In the pos mode: Return the drive to the traversing range using jog key 1 or 2.
- In the n-set mode: Enter a setpoint that opposes the approach direction.
- Acknowledgement
- not required
- Stop response
- STOP VII
801Plus hardware limit switch
#801Cause
A 1/0 edge was identified at the ”Plus hardware limit switch” input signal.
Remedy
- In the pos mode: Return the drive to the traversing range using jog key 1 or 2.
- In the n-set mode: Enter a setpoint that opposes the approach direction.
- Acknowledgement
- not required
- Stop response
- STOP VII
802Drive rotates in response to angular encoder output parameters
#802Cause
The drive was not stationary as the zero pulse offset was programmed on the angular encoder interface. Low speeds are not critical, but the inaccuracy of the zero pulse position increases in proportion to speed.
Remedy
Ensure that the drive is at a standstill, or take into account a higher inaccuracy of the zero pulse.
- Acknowledgement
- not required
- Stop response
- STOP VII
804Controller enable or on/off 1(edge) or on/off 2/3 missing
#804Cause
When starting a traversing block, the controller enable has not been set, or the controller enable is missing during a traversing program when re-starting the axis from standstill. Controller enable missing, i.e. one of the following signals missing:
- PROFIBUS control signals (STW1.0: ON/OFF 1 (signal edge), STW1.1: OC/OFF2, STW1.2: OC/OFF 3, STW1.3: Enable inverter/pulse inhibit) and the appropriate signals of the bus interface
- PC enable (SimoCom U)
- Terminal 64
- Terminal 65.x
Remedy
Set the missing signal, and re-start the traversing block or enter a signal edge via PROFIBUS.
- Acknowledgement
- not required
- Stop response
- STOP VII
805Pulse enable missing
#805Cause
When starting a traversing block, the pulse enable is not set, or the pulse enable is missing during a traversing program when re-starting the axis from standstill. Pulse enable missing, i.e. one of the following signals missing:
- PROFIBUS control signals (STW1.1: OC/OFF 2, STW1.3: Enable inverter/pulse inhibit) or the appropriate signals of the bus interface
- Terminal 48 (NE module)
- Terminal NS1/NS2 (NE module)
- Terminal 63 (NE module)
- Terminal 663 (control module)
Remedy
Set the missing enable signal and then re-start the traversing block.
- Acknowledgement
- not required
- Stop response
- STOP VII
806OC/reject traversing task missing
#806Cause
When starting a traversing block, the ”operating condition/reject traversing task” input signal is not set.
Remedy
Set the ”operating condition/reject traversing task” input signal and then re-start the traversing block.
- Acknowledgement
- not required
- Stop response
- STOP VII
807OC/intermediate stop missing
#807Cause
When starting a traversing block the ”operating condition/intermediate stop” input signal is not set.
Remedy
Set the ”operating condition/intermediate stop” input signal and then re-start the traversing block.
- Acknowledgement
- not required
- Stop response
- STOP VII
808Reference point not set
#808Cause
When starting a traversing block, a reference point is not set.
Remedy
Execute referencing or set a reference point using the ”set reference point” input signal.
- Acknowledgement
- not required
- Stop response
- STOP VII
809Parking axis selected
#809Cause
When starting a traversing block or when starting referencing, the ”parking axis” function is selected.
Remedy
Cancel the ”parking axis” function and then re-start the required function.
- Acknowledgement
- not required
- Stop response
- STOP VII
814Motor temperature, pre-alarm
#814Cause
The motor temperature is sensed via a temperature sensor (KTY84) and evaluated on the drive side. This alarm is output if the motor temperature reaches the alarm threshold motor overtemperature (P1602).
Remedy
- Avoid many acceleration and braking operations which follow one another quickly.
- Check whether the motor output is sufficient for the drive, otherwise use a higher output motor, possibly in conjunction with a higher-rating power section.
- Check the motor data. The motor current could be too high due to incorrect motor data.
- Check the temperature sensor.
- Check the motor fan.
- Acknowledgement
- not required
- Stop response
- STOP VII
815Power module temperature, pre-alarm
#815Cause
The heatsink temperature of the power section is sensed using a thermosensor on the main heatsink. If the overtemperature condition remains, then the drive shuts down after approx. 20 s.
Remedy
Improve the drive module cooling, e.g. using:
- Higher airflow in the switching cabinet, possibly cool the ambient air of the drive modules
- Avoid many acceleration and braking operations which follow quickly one after the other
- Check that the power section for the axis/spindle is adequate, otherwise use a higher-rating module
- Ambient temperature too high (refer to the Planning Guide)
- Permissible installation altitude exceeded (refer to the Planning Guide)
- Pulse frequency too high (refer to the Planning Guide)
- Check fan, if required, replace
- Maintain the minimum clearance above and below the power section (refer to the Planning Guide)
- Acknowledgement
- not required
- Stop response
- STOP VII
816Resolver sensing at its limit
#816Cause
At run-up, the speed with an existing resolver evaluation was extremely high. It is possible that this was not the actual speed, and that the resolver was not connected to the measuring circuit input.
Remedy
Insert the measuring circuit connector and enter a reset.
- Acknowledgement
- not required
- Stop response
- STOP VII
820Power module in i2t limiting
#820Cause
The power module is being operated too long above the permissible load limit.
Remedy
- Avoid many acceleration and braking operations which follow quickly one after the other
- Check that the power section for the axis/spindle is adequate, otherwise use a higher-rating module
- Pulse frequency too high (refer to the Planning Guide)
- Check P1260 and P1261
- Acknowledgement
- not required
- Stop response
- STOP VII
827Fieldbus is not in the data exchange state
#827Cause
The bus interface is still not in the data exchange state or data exchange was interrupted.
Causes:
- The master has not yet run up, or has not yet established a connection to the slave.
- The bus addresses differ in the master configuring and slave parameterization.
- The bus connection has been physically interrupted.
- The master is still in the clear condition.
- An illegal parameterization or configuration was received.
- A BUS address was assigned several times.
Remedy
Master, check the assignment of bus addresses and bus connection.
- Acknowledgement
- not required
- Stop response
- STOP VII
828Fieldbus is not in clock-cycle synchronism to the master
#828Cause
The bus interface is in the data exchange state and was selected using the parameterizing telegram of the clock-cycle synchronous operation. It was not possible to synchronize to the clock cycle specified by the master and to the master sign of life.
Causes:
- The master does not send an equidistant global control frame although clock synchronism has been selected via the bus configuration.
- The master uses another equidistant DP clock cycle than was transferred to the slave in the parameterizing telegram.
- The master does not increment its sign-of-life in the configured time grid Tmapc.
Remedy
Check master application and bus configuration Check the consistency between the clock cycle input for the slave configuring and the clock cycle setting at the master. If the master (e.g. SIMATIC S7) does not transfer a sign-of-life, the sign-of-life evalution can also be suppressed using P0879 bit 8.
- Acknowledgement
- not required
- Stop response
- STOP VII
829PROFIBUS: Illegal parameterization received. Reason: \%u
#829Cause
An illegal parameterizing frame was received via PROFIBUS. Cyclic data transfer cannot start. Reasons: 8 = The parameterizing telegram has an illegal length 9 = The length data in the equidistant block is illegal 10 = A block header has an unknown ID. 11 = The basis time Tbasedp is not permissible (not equal to 125 µs). 12 = The DP clock cycle Tdp is not permissible (less than 1ms or greater than 32ms). 13 = The time Tmapc is less than 1*Tdp or greater than 14*Tdp. 14 = The base time Tbaseio is not permissible (not equal to 125 µs). 15 = Time Ti is greater than the DP clock cycle (Tdp). 16 = Time To is greater than the DP clock cycle (Tdp). 17 = For active Data Exchange, a new parameterization was received with different contents. 18 = Clock cycle synchronous operation was selected without a suitable option module having been activated (refer to P0875). 19 = IsoM_Req (state 3, bit 4) is requested in the DPV1 header without there being an isochron block (ID 0x04). 20 = Fail_Safe (state 1, bit 6), IsoM_Req (state 3, bit 4) or Prm_Structure (state 3, bit3) missing in the DPV1 header although an isochron block (ID 0x04) is available. 21 = The time Tdx is greater than (To – 125us) or greater than (Tdp – 250 µs). 22 = The time Tpllw is greater than 1us. 23 = Slave-to-slave communication access target address and length do not conform to word boundary. 24 = Maximum number (3 external + 1 internal) of slave-to-slave communication links has been exceeded. 25 = Maximum number (8) of accesses per link has been exceeded. 26 = Unknown version ID in the slave-to-slave communications block. 27 = The maximum overall length of the filter table has been exceeded. 31 = The permitted maximum length of the parameterizing telegram for the option module has been exceeded. 32 = The option module firmware does not support slave-to-slave communications
Remedy
Check the bus configuration at the master, and if required correct the parameterization. If required, insert (reason 18) a suitable option module and activate. If required, (reason 31 or reason 32) upgrade the option module firmware to a version greater than or equal to 04.01.
- Acknowledgement
- not required
- Stop response
- STOP VII
830PROFIBUS: Illegal configuration received. Reason: \%u
#830Cause
An illegal configuration frame was received via PROFIBUS. Cyclic data transfer cannot start. Reasons: 1 = In the master, more axes are configured than are physically present in the power module. 2 = The number of the axes configured in the master is not equal to the number axes where the PROFIBUS DP option module is switched active via P0875. Note: Communications with axis B are not automatically de-activated even when switching axis B into a passive state. 3 = Configuration incomplete (too short) for one of the PPL types (only for vor P875 = 2). 4 = No PPO type detected (only for P875 = 2). 5 = Length calculation different between firmware and option module. 6 = For active data exchange, a new configuration was received with different length. 7 = Configuration contained unknown S7 ID. 19 = More PZD’s have been configured than the maximum permissible. 20 = The configurtion contains an unknown special character (only axis separators are permitted). 22 = Target offset of slave-to-slave communications access exceeds the maximum number of PZDs 28 = Number of slave-to-slave communication IDs differs from the number of accesses in the parameterizing telegram. 29 = Setpoint PZDs are not uniformly supplied by the master or slave (drive) publisher. 30 = The permitted maximum length of the configuration telegram for the option module has been exceeded.
Remedy
Check the bus configuring at the master and if required correct. If required, using P875, activate the option module PROFIBUS-DP, which are previously configured in the PROFIBUS Master for the number of axes involved.
- Acknowledgement
- not required
- Stop response
- STOP VII
831PROFIBUS is not in the data transfer condition
#831Cause
The PROFIBUS is not in a data transfer status (data exchange) or data transfer was interrupted.
Causes:
- The master has not yet run up, or has not yet established a connection to the slave.
- The bus addresses differ in the master configuring and slave parameterization.
- The bus connection has been physically interrupted.
- The master is still in the clear condition.
- An illegal parameterization or configuration was received.
- A PROFIBUS address was assigned several times.
Remedy
Master, check the assignment of bus addresses and bus connection.
- Acknowledgement
- not required
- Stop response
- STOP VII
832PROFIBUS not clock-synchronous with the master
#832Cause
The PROFIBUS is in a data transfer status (data exchange) and has been selected via the parameterizing frame of synchronous operation. It could not yet be synchronized to the clock preset by the master resp. to the master sign-of-life.
Causes:
- The master does not send an equidistant global control frame although clock synchronism has been selected via the bus configuration.
- The master uses another equidistant DP clock cycle than was transferred to the slave in the parameterizing telegram.
- The master increments its sign-of-life (STW2 Bits 12–15) not in the configured time frame Tmapc.
Remedy
Check master application and bus configuration Check the consistency between the clock cycle input for the slave configuring and the clock cycle setting at the master. If the master (e.g. SIMATIC S7) does not transfer a sign-of-life, the sign-of-life evalution can also be suppressed using P0879 bit 8.
- Acknowledgement
- not required
- Stop response
- STOP VII
833PROFIBUS: No connection to the publisher \%u
#833Cause
Cyclic data transfer between this slave and a slave-to-slave communications publisher was still not started or was interrupted.
Examples:
- Bus connection interrupted
- Publisher failure
- Master runs up again
- The response monitoring (Watchdog) for this slave was de-activated via the parameterizing telegram (SetPrm) (Diagnostics: P1783:1 bit 3 = 0).
Supplementary info: PROFIBUS address of the publisher
Remedy
Check the publisher and bus connections to the publisher, to the master and between the master and publisher. if the watchdog is de-activated, activate the response monitoring for this slave via Drive ES.
- Acknowledgement
- not required
- Stop response
- STOP VII
840Teach-in for running traversing program
#840Cause
Teach-in was requested during a running traversing program.
Remedy
Exit the traversing program and re-request teach-in.
- Acknowledgement
- not required
- Stop response
- STOP VII
841Teach-in for relative block
#841Cause
The traversing block as ”teach in block” is relative instead of absolute.
Remedy
Change the traversing block mode ”teach in block” from relative to absolute.
- Acknowledgement
- not required
- Stop response
- STOP VII
842Teach-in for a relative standard block
#842Cause
The traversing block as ”teach in standard set”, is relative instead of absolute.
Remedy
Change the traversing block mode ”teach in standard block” from relative to absolute.
- Acknowledgement
- not required
- Stop response
- STOP VII
843Search velocity too high
#843Cause
The search velocity for spindle positioning is too high for the selected maximum deceleration.
Remedy
Reduce search velocity P0082:64 or increase the maximum deceleration P0104.
- Acknowledgement
- not required
- Stop response
- STOP VII
845Jogging not effective for active coupling
#845Cause
Jogging is not possible while a coupling is closed.
Remedy
Release the coupling and re-activate jogging.
- Acknowledgement
- not required
- Stop response
- STOP VII
849PLUS software limit switch actuated
#849Cause
For a block with the ENDLOS_POS command, the axis has actuated the plus software limit switch (P0316) for absolute or relative positioning. The behavior for software limit switch reached, can be set using P0118.0.
Remedy
- Move away in the negative direction, jogging.
- Move away in the negative direction using the traversing block.
- Acknowledgement
- not required
- Stop response
- STOP VII
850MINUS software limit switch actuated
#850Cause
For a block with the ENDLOS_NEG command, the axis has actuated the minus software limit switch (P0315) for absolute or relative positioning The behavior for software limit switch reached, can be set using P0118.0.
Remedy
- Move away in the positive direction, jogging.
- Move away in the positive direction using the traversing block.
- Acknowledgement
- not required
- Stop response
- STOP VII
864Parameterization error in speed controller adaptation
#864Cause
The upper adaption speed (P1412) was parameterized with a lower value than the lower adaption speed (P1411).
Remedy
P1412 must contain a higher value than P1411.
- Acknowledgement
- not required
- Stop response
- STOP VII
865Invalid signal number
#865Cause
The signal number for the analog output is not permissible. An analog value can be output for diagnostic, service and optimization tasks Term. 75.x/15, 16.x/15, DAC1, DAC2
Remedy
Enter valid signal number (refer to the Description of Functions SIMODRIVE 611 universal)
- Acknowledgement
- not required
- Stop response
- STOP VII
866Parameterizing error, current controller adaption
#866Cause
For the current controller adaption, the upper current limit (P1181) was parameterized with a lower value than the lower current limit (P1180). Adaption is de-activated when the parameterizing error is output.
Remedy
P1181 must contain a higher value than P1180.
- Acknowledgement
- not required
- Stop response
- STOP VII
867Generator mode: Response voltage > shutdown threshold
#867Cause
The sum of the values in P1631 + P1632 is greater than the value in P1633.
Remedy
Appropriately change P1631, P1632 and P1633.
Note: P1631 to P1633 being prepared
- Acknowledgement
- not required
- Stop response
- STOP VII
868Generator mode: Response voltage > monitoring threshold
#868Cause
The input value for the threshold voltage (P1631) is greater than the value in P1630.
Remedy
Change the drive parameters.
Note: P1630 and P1631 being prepared
- Acknowledgement
- not required
- Stop response
- STOP VII
869Reference point coordinate limited to modulo range
#869Cause
The reference point coordinate is internally limited to the modulo range.
Remedy
Enter a value in P0160 which lies within the modulo range (P0242).
- Acknowledgement
- not required
- Stop response
- STOP VII
870Jerk: jerk time is limited
#870Cause
When calculating the jerk time T from the acceleration a and the jerk r, the result was an excessively high jerk time, so that the time is limited internally. The following is valid: T = a/r, where a: Acceleration (higher value from P0103 and P0104) r: Jerk (P0107)
Remedy
- Increase jerk (P0107)
- Reduce maximum acceleration (P0103) or maximum deceleration (P0104)
- Acknowledgement
- not required
- Stop response
- STOP VII
871Induction motor operation: drive converter frequency motor not permissible
#871Cause
In induction motor operation (selected by P1465 < P1146), drive converter frequencies of 4 or 8 kHz are permissible.
Remedy
- Change P1100
- Cancel induction motor operation (P1465 > P1146)
- Acknowledgement
- not required
- Stop response
- STOP VII
872PARAMETERIZING ERROR: P gain, equalization controller too high
#872Cause
PARAMETERIZING ERROR: P gain, equalization controller does not fit into the format.
Remedy
- Change P1491
- Acknowledgement
- not required
- Stop response
- STOP VII
875Axial deviations in fixed voltage
#875Cause
For the axes of a drive module, an unequal fixed voltage (P1161) has been set. As a fixed voltage <> 0 replaces the DC link voltage measured value, but the DC link voltage is only measured once for all drives of a drive module, the fixed voltage on all module axes must be equal, before it is accepted.
Remedy
Set the same fixed voltage (P1161) on all module axes.
- Acknowledgement
- not required
- Stop response
- STOP VII
876Terminal function \%u in the actual mode illegal
#876Cause
The function number, used as input terminal or distributed input (P0888) may not be used in the actual mode.
Remedy
Change P0700 (operating mode) or enter a suitable function number in P0888 or P0660, P0661 etc.
- Acknowledgement
- not required
- Stop response
- STOP VII
877Output function \%u not permissible in the actual operating mode
#877Cause
The function number, used as output, may not be used in the actual operating mode.
Remedy
Change P0700 (operating mode) or enter a suitable function number in P0680, P06981, etc.
- Acknowledgement
- not required
- Stop response
- STOP VII
878Input I0.x not parameterized as equivalent zero mark
#878Cause
When entering an external signal as equivalent zero mark (P0174 = 2), input I0.x must be assigned ”equivalent zero mark” function (Fct. No.:79). if a direct measuring system is used, input I0.B must be assigned the ”equivalent zero mark” function (Fct. No.: 79).
Remedy
- Motor measuring system: P0660 = 79
- Direct measuring system: P0672 = 79
- Acknowledgement
- not required
- Stop response
- STOP VII
879Time constant deadtime, speed feedforward control (P0205:\%u) too high
#879Cause
P0205:8 may not be greater than two position controller clock cycles. Higher values are internally limited.
Remedy
Reduce P0205:8 to max. two position controller clock cycles (P1009). Parameterize an addition delay via P0206:8.
- Acknowledgement
- not required
- Stop response
- STOP VII
881PZD configuring: Signal number in P0915:\%u invalid
#881Cause
An undefined or illegal signal number in the current operating mode (P0700) was identified for the process data software. P0915:1 is not equal to 50001 (STW1). The process data for encoder 1 has been configured although encoderless operation is activated (P1011.5). The process data for encoder 2 were configured although the direct measuring system is not activated (P0879.12).
Remedy
Correct P0915:17
- Acknowledgement
- not required
- Stop response
- STOP VII
882PZD configuring: Double word signal number in P0915:\%u invalid
#882Cause
For signals with double words (length = 32 bits), the corresponding signal identifier must be configured twice for adjacent process data. The following subparameter must therefore also be parameterized with the same signal number.
Remedy
Correct P0915:17
- Acknowledgement
- not required
- Stop response
- STOP VII
883PZD configuring: Signal number in P0916:\%u invalid
#883Cause
An undefined or illegal signal number in the current operating mode (P0700) was identified for the process data software. P0916:1 is not equal to 50002 (ZSW1). The process data for encoder 1 has been configured although encoderless operation is activated (P1011.5). The process data for encoder 2 were configured although the direct measuring system is not activated (P0879.12).
Remedy
Correct P0916:17
- Acknowledgement
- not required
- Stop response
- STOP VII
884PZD configuring: Double word signal number in P0916:\%u ivalid
#884Cause
For signals with double words (length = 32 bits), the corresponding signal identifier must be configured twice for adjacent process data. The following subparameter must therefore also be parameterized with the same signal number.
Remedy
Correct P0916:17
- Acknowledgement
- not required
- Stop response
- STOP VII
885P1261 greater than 100.0 % not permissible
#885Cause
P1261 greater than 100.0 % is not permissible for permanent-magnet synchronous motors with field weakening (PE spindle, P1015 = 1). It is internally limited to 100.0 %.
Remedy
Set P1261 to max. 100.0 %.
- Acknowledgement
- not required
- Stop response
- STOP VII
886Pre-tensioning torque greater than 16x rated torque
#886Cause
The parameterized pre-tensioning torque (P1493) is greater than 16x the standstill torque (SRM), rated motor torque (ARM) and standstill force (SLM) of the motor.
Note: refer to the index entry ”Limits”
Remedy
Reduce pre-tensioning torque (P1493)
- Acknowledgement
- not required
- Stop response
- STOP VII
889Fixed endstop, axis has not reached the clamping torque
#889Cause
The axis has reached the fixed endstop, but was not able to establish the programmed clamping torque.
Remedy
Check the parameters for the limits.
- Acknowledgement
- not required
- Stop response
- STOP VII
890Acceleration – deceleration override incorrect
#890Cause
The acceleratino override or the deceleration override is not in the range from 1% to 100%. if the value > 100%, then it is limited to 100%. If the value < 1%, then limited to 1%. The traversing block is not interrupted.
Remedy
Check the programming of the acceleration override and deceleration override.
- Acknowledgement
- not required
- Stop response
- STOP VII
891PLUS software limit switch actuated coupled
#891Cause
With the actual master drive velocity, this coupling axis will probably reach or pass the PLUS software limit switch. This warning is output if the coupled axis has fallen below 200% of the braking travel up to the PLUS software limit switch.
Remedy
Traverse the master drive so that this coupling axis goes into the permissible traversing range.
- Acknowledgement
- not required
- Stop response
- STOP VII
892MINUS software limit switch actuated coupled
#892Cause
With the actual master drive velocity, this coupling axis will probably reach or pass the MINUS software limit switch. This warning is output if the coupled axis has fallen below 200% of the braking travel up to the MINUS software limit switch.
Remedy
Traverse the master drive so that this coupling axis goes into the permissible traversing range.
- Acknowledgement
- not required
- Stop response
- STOP VII
893Function 73 only effective at terminal I0.x
#893Cause
The terminal function 73 ”Coupling on I0” is only effective at terminal I0.x.
Remedy
Assign terminal I0.x to function 73.
- Acknowledgement
- not required
- Stop response
- STOP VII
894Inputs, optional TERMINAL module assigned twice
#894Cause
The input terminals on the optional TERMINAL module can only be used by one drive.
Remedy
Check and correct P0676 (A) and P0676 (B).
- Acknowledgement
- not required
- Stop response
- STOP VII
895Outputs, optional TERMINAL module assigned twice
#895Cause
Only one drive can use the output terminals on the optional TERMINAL module.
Remedy
Check and correct P0696 (A) and P0696 (B).
- Acknowledgement
- not required
- Stop response
- STOP VII
Need a SIMODRIVE 611 spare part or repair?
Send the complete order number, a photo of the nameplate, the displayed alarm and a description of the fault.
Source: Siemens AG, SIMODRIVE 611 universal Function Manual (FBU), edition 04/2006, section 7.3.2, list version 09.02.04. Original diagnostic wording is retained in English; line wrapping and presentation have been adapted for the web. Cross-references in the original text refer to the complete Siemens manual.
© Siemens AG 2006. All rights reserved.