7015-4P2T-T1L - VOLKTEK Industrial Single Pair Ethernet switch / SPoE

7015-4P2T-T1L - VOLKTEK Industrial Single Pair Ethernet switch / SPoE


VOLKTEK

VOLKTEK 7015-4P2T-T1L: 2× RJ45 / 10/100 Mbit/s; 4× 10BASE-T1L / SPoE / 10 Mbit/s. Unmanaged; SPoE / 132W. 20-30 V DC / class 10-12; 50-58 V DC / class 13-14; IP40; -40…+70 °C. More

Code: 7015-4P2T-T1L

Rezervace termínu

Get a quote
VOLKTEK

VOLKTEK 7015-4P2T-T1L: 2× RJ45 / 10/100 Mbit/s; 4× 10BASE-T1L / SPoE / 10 Mbit/s. Unmanaged; SPoE / 132W. 20-30 V DC / class 10-12; 50-58 V DC / class 13-14; IP40; -40…+70 °C. More

Code: 7015-4P2T-T1L

VOLKTEK 7015-4P2T-T1L

Industrial Single Pair Ethernet switch / SPoE

Four 10BASE-T1L ports connect Single Pair Ethernet devices and carry data and SPoE power over one wire pair. Two RJ45 ports connect to a standard 10/100 Mbit/s Ethernet network.

2× RJ45 / 10/100 Mbit/s4× 10BASE-T1L / SPoE / 10 Mbit/sUnmanaged20-30 V DC / class 10-12; 50-58 V DC / class 13-14

DIP switch configuration: SPoE / Class / Auto / Master / Slave

VOLKTEK 7015-4P2T-T1L - Overall device view
Overall device view. Click to enlarge the image.

We will select a switch for your network
We will review endpoints, ports and power, then confirm price, current availability and delivery time for a new product.

Enquire about a VOLKTEK solution
4× SPoE14 W @ 24 V / 33 W @ 55 V
UnmanagedConnect without configuration
-40…+70 °CIP40 / DIN rail

Applications and device connections

Single Pair Ethernet connects remote sensors and other compatible endpoints. Reach up to 1000 m depends on suitable cabling and installation conditions. SPoE power requires a matching PD and correctly selected power class.

Connect without configuration

The device operates without web management or a switch IP address setting. Once power and Ethernet cables are connected, it interconnects the end devices. Set PLC, HMI and other device addresses on those devices.

Endpoint power supply

This model does not supply PoE through its RJ45 ports. SPoE is available on four 10BASE-T1L ports. Use 20-30 V DC for classes 10-12 and 50-58 V DC for classes 13-14. The per-port maximum is 14 W at 24 V or 33 W at 55 V; the total budget is 132 W.

Power supply and alarm

20-30 V DC / class 10-12; 50-58 V DC / class 13-14. Follow input voltage, polarity and specified wiring. Select the supply for switch consumption, endpoint power and operating reserve.

DIP switch configuration

DIP switches enable SPoE, select the power class and set automatic/manual operation and Master/Slave roles per port. The class must match the connected PD. Use opposite Master and Slave roles in manual mode. Power-cycle the device to apply changes.

Set switch positions according to device labels and the supplied installation guide.

Technical specifications

Order codeVOLKTEK 7015-4P2T-T1L
ManagementUnmanaged
Data interface2× RJ45 / 10/100 Mbit/s
Optical interface4× 10BASE-T1L / SPoE / 10 Mbit/s
Power supply20-30 V DC / class 10-12; 50-58 V DC / class 13-14
Power consumption4 W
Network power standardIEEE 802.3cg / 10BASE-T1L / SPoE
PoE port count4× SPoE / 10BASE-T1L
Maximum port power14 W @ 24 V / 33 W @ 55 V
Power budget132W
DIPDIP switches enable SPoE, select the power class and set automatic/manual operation and Master/Slave roles per port. The class must match the connected PD. Use opposite Master and Slave roles in manual mode. Power-cycle the device to apply changes.
Protection ratingIP40
MountingDIN rail
Operating temperature-40…+70 °C
Dimensions (W × H × D)31 × 136 × 105 mm
Weight525 g

Interfaces and mounting

VOLKTEK 7015-4P2T-T1L - Interface diagram
Interface diagram. Original manufacturer diagram with English labels. Click to enlarge the image.
VOLKTEK 7015-4P2T-T1L - Dimensional drawing
Dimensional drawing. Click to enlarge the image.

Install in a suitable cabinet or protective enclosure. Provide grounding, free airflow and access to connectors. Neither IP30 nor IP40 provides protection against water. Wire with power disconnected and follow the installation guide.

Package contents

The standard set contains the switch and mounting accessories for the selected version. Power supply, fibre modules and data cabling are selected separately. We will confirm the complete delivery contents in the quotation.

Downloads

Original VOLKTEK documentation in English. Files are also available in the Downloads tab.

VOLKTEK 7015-4P2T-T1L - Datasheet (EN)VOLKTEK / ENOpen PDF
VOLKTEK 7015-4P2T-T1L - Quick installation guide (EN)VOLKTEK / ENOpen PDF

VOLKTEK videos

Official VOLKTEK video about the technology or product range. The video is in English; see the table and documents above for exact model specifications.

VOLKTEK technology and solutions

Frequently asked questions

Does this switch support management?

Unmanaged. The device operates without web management or a switch IP address setting. Once power and Ethernet cables are connected, it interconnects the end devices. Set PLC, HMI and other device addresses on those devices.

Which power supply do I need?

20-30 V DC / class 10-12; 50-58 V DC / class 13-14. Follow input voltage, polarity and specified wiring. Select the supply for switch consumption, endpoint power and operating reserve.

What do the DIP switches configure?

DIP switches enable SPoE, select the power class and set automatic/manual operation and Master/Slave roles per port. The class must match the connected PD. Use opposite Master and Slave roles in manual mode. Power-cycle the device to apply changes. Set switch positions according to device labels and the supplied installation guide.

How do I select the right optics?

This model has no fibre slots. See the technical table for interfaces.

What power does it supply to endpoints?

This model does not supply PoE through its RJ45 ports. SPoE is available on four 10BASE-T1L ports. Use 20-30 V DC for classes 10-12 and 50-58 V DC for classes 13-14. The per-port maximum is 14 W at 24 V or 33 W at 55 V; the total budget is 132 W.

Will you check model suitability and availability?

We supply new original VOLKTEK products with warranty. We help select the switch, supply, optics and accessories. Before ordering, we check price, current stock availability and delivery time.

Why buy from FOXON

We are a VOLKTEK distributor. We supply new original products with warranty and technical support.

New products with warranty

New original product with warranty. Availability and delivery time confirmed on enquiry.

Technical support

We advise on interfaces, optics, power and accessories for your application.

Availability and delivery

We will check current availability, price and possible delivery time before ordering.

Pre-purchase consultation

We will review endpoints, ports and power, then confirm price, current availability and delivery time for a new product.

More than 3,500customers
We supply tomore than 100 countries worldwide
Express delivery?We’ll look into it; please contact us immediately.

Enquiry and technical consultation

Send the quantity, connected devices, power supply, cable type and link distance. We will help select a suitable version and prepare a quotation.

We will select a switch for your network
We will review endpoints, ports and power, then confirm price, current availability and delivery time for a new product.

Enquire about a VOLKTEK solution

Technical specifications

Order codeVOLKTEK 7015-4P2T-T1L
ManagementUnmanaged
Data interface2× RJ45 / 10/100 Mbit/s
Optical interface4× 10BASE-T1L / SPoE / 10 Mbit/s
Power supply20-30 V DC / class 10-12; 50-58 V DC / class 13-14
Power consumption4 W
Network power standardIEEE 802.3cg / 10BASE-T1L / SPoE
PoE port count4× SPoE / 10BASE-T1L
Maximum port power14 W @ 24 V / 33 W @ 55 V
Power budget132W
DIPDIP switches enable SPoE, select the power class and set automatic/manual operation and Master/Slave roles per port. The class must match the connected PD. Use opposite Master and Slave roles in manual mode. Power-cycle the device to apply changes.
Protection ratingIP40
MountingDIN rail
Operating temperature-40…+70 °C
Dimensions (W × H × D)31 × 136 × 105 mm
Weight525 g

Endpoint power supply

This model does not supply PoE through its RJ45 ports. SPoE is available on four 10BASE-T1L ports. Use 20-30 V DC for classes 10-12 and 50-58 V DC for classes 13-14. The per-port maximum is 14 W at 24 V or 33 W at 55 V; the total budget is 132 W.

DIP switch configuration

DIP switches enable SPoE, select the power class and set automatic/manual operation and Master/Slave roles per port. The class must match the connected PD. Use opposite Master and Slave roles in manual mode. Power-cycle the device to apply changes.

Set switch positions according to device labels and the supplied installation guide.

Frequently asked questions

Does this switch support management?

Unmanaged. The device operates without web management or a switch IP address setting. Once power and Ethernet cables are connected, it interconnects the end devices. Set PLC, HMI and other device addresses on those devices.

Which power supply do I need?

20-30 V DC / class 10-12; 50-58 V DC / class 13-14. Follow input voltage, polarity and specified wiring. Select the supply for switch consumption, endpoint power and operating reserve.

What do the DIP switches configure?

DIP switches enable SPoE, select the power class and set automatic/manual operation and Master/Slave roles per port. The class must match the connected PD. Use opposite Master and Slave roles in manual mode. Power-cycle the device to apply changes. Set switch positions according to device labels and the supplied installation guide.

How do I select the right optics?

This model has no fibre slots. See the technical table for interfaces.

What power does it supply to endpoints?

This model does not supply PoE through its RJ45 ports. SPoE is available on four 10BASE-T1L ports. Use 20-30 V DC for classes 10-12 and 50-58 V DC for classes 13-14. The per-port maximum is 14 W at 24 V or 33 W at 55 V; the total budget is 132 W.

Will you check model suitability and availability?

We supply new original VOLKTEK products with warranty. We help select the switch, supply, optics and accessories. Before ordering, we check price, current stock availability and delivery time.