Converter Modbus TCP Client / DALI - HD67844-B2

Converter Modbus TCP Client / DALI - HD67844-B2


ADFweb

The ADFweb HD67844-B2 connects Modbus TCP Server devices to DALI lighting. As a Modbus TCP Client, it actively reads and writes registers and maps them to DALI values and commands. More

Code: HD67844-B2

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67844-B2 connects Modbus TCP Server devices to DALI lighting. As a Modbus TCP Client, it actively reads and writes registers and maps them to DALI values and commands. More

Code: HD67844-B2

ADFweb HD67844-B2

Modbus TCP Client / DALI

The ADFweb HD67844-B2 connects Modbus TCP Server devices to DALI lighting. As a Modbus TCP Client, it actively reads and writes registers and maps them to DALI values and commands.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
Modbus TCP Client / DALIProtocol connection
DALI; EthernetHardware version
SW67844Configuration tool

Converter applications

Use it to link DALI lighting to registers of existing meters, controllers or other Modbus Slave/Server devices. DALI Console is used for addressing luminaires, groups, scenes and communication tests.

Technical specifications HD67844-B2

Order codeHD67844-B2
Protocol connectionModbus TCP Client / DALI
Roles and versionModbus TCP Client; DALI
Interfaces and portsDALI; Ethernet RJ45
DALI capacityup to 64 devices
DALI data rate1 200 bit/s
DALI bus powerVersion -Y with bus power; -N without bus power. Select before ordering.
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67844; DALI Console

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67844, configure Modbus TCP network settings, connected DALI nodes and register mapping. Use DALI Console to prepare addresses, groups and scenes and test communication with luminaires.

The peer must operate as a Modbus TCP Server. Prepare register addresses, data types, byte order and the required read/write polling cycle. The base code HD67844-B2 does not specify DALI bus power. Before ordering, we will select HD67844-B2-Y with DALI bus power or HD67844-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67844-B2
Dimensional drawing of the version shown - HD67844-B2

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The peer must operate as a Modbus TCP Server. Prepare register addresses, data types, byte order and the required read/write polling cycle. The base code HD67844-B2 does not specify DALI bus power. Before ordering, we will select HD67844-B2-Y with DALI bus power or HD67844-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.

How is this converter configured?

In SW67844, configure Modbus TCP network settings, connected DALI nodes and register mapping. Use DALI Console to prepare addresses, groups and scenes and test communication with luminaires.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The peer must operate as a Modbus TCP Server. Prepare register addresses, data types, byte order and the required read/write polling cycle. The base code HD67844-B2 does not specify DALI bus power. Before ordering, we will select HD67844-B2-Y with DALI bus power or HD67844-B2-N without it to match the installation. We will also check support for the functions of the specific luminaires and their control gear.

Converter enquiry HD67844-B2

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67844-B2

Order codeHD67844-B2
Protocol connectionModbus TCP Client / DALI
Roles and versionModbus TCP Client; DALI
Interfaces and portsDALI; Ethernet RJ45
DALI capacityup to 64 devices
DALI data rate1 200 bit/s
DALI bus powerVersion -Y with bus power; -N without bus power. Select before ordering.
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)60 × 35 × 95 mm
Device weightapproximately 200 g
Configuration softwareSW67844; DALI Console

For an older device, check the hardware version and connections against its label.