Converter EtherCAT Slave / CANopen - HD67E08-A1

Converter EtherCAT Slave / CANopen - HD67E08-A1


ADFweb

The ADFweb HD67E08-A1 connects a CANopen network to an EtherCAT control system. It exchanges process data as an EtherCAT Slave and uses configured PDO and SDO objects on the CANopen side. More

Code: HD67E08-A1

449 EUR excl. VAT (543,29 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67E08-A1 connects a CANopen network to an EtherCAT control system. It exchanges process data as an EtherCAT Slave and uses configured PDO and SDO objects on the CANopen side. More

Code: HD67E08-A1

ADFweb HD67E08-A1

EtherCAT Slave / CANopen

The ADFweb HD67E08-A1 connects a CANopen network to an EtherCAT control system. It exchanges process data as an EtherCAT Slave and uses configured PDO and SDO objects on the CANopen side.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
EtherCAT Slave / CANopenProtocol connection
35 mm DIN railHardware version
SW67E08Configuration tool

Converter applications

Use it to exchange values between an EtherCAT Master application and CANopen devices. Configure PDO reception/transmission and SDO Client/Server object dictionary access for the specific installation.

Technical specifications HD67E08-A1

Order codeHD67E08-A1
Protocol connectionEtherCAT Slave / CANopen
Converter rolesEtherCAT Slave; CANopen with PDO and SDO Client/Server services
Interfaces and ports2× EtherCAT RJ45 (IN/OUT); CANopen; Ethernet RJ45 for configuration
CANopen data rateup to 1 Mbit/s
CANopen communicationPDO (RPDO/TPDO); SDO Client/Server
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)120 × 23 × 107 mm
Device weightapproximately 200 g
Configuration softwareSW67E08

For an older device, check the hardware version and connections against its label.

Communication and configuration

In SW67E08, configure EtherCAT, the CANopen node identifier, data rate and PDO/SDO mapping. The software exports an ESI file for the EtherCAT Master and an EDS file for the CANopen Master.

The gateway requires an EtherCAT Master. Match CANopen node identifiers, objects, data types and network state; a matching CAN connector alone is insufficient. Distinguish configuration Ethernet from EtherCAT.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67E08-A1
Dimensional drawing of the version shown - HD67E08-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. The gateway requires an EtherCAT Master. Match CANopen node identifiers, objects, data types and network state; a matching CAN connector alone is insufficient. Distinguish configuration Ethernet from EtherCAT.

How is this converter configured?

In SW67E08, configure EtherCAT, the CANopen node identifier, data rate and PDO/SDO mapping. The software exports an ESI file for the EtherCAT Master and an EDS file for the CANopen Master.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

The gateway requires an EtherCAT Master. Match CANopen node identifiers, objects, data types and network state; a matching CAN connector alone is insufficient. Distinguish configuration Ethernet from EtherCAT.

Converter enquiry HD67E08-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67E08-A1

Order codeHD67E08-A1
Protocol connectionEtherCAT Slave / CANopen
Converter rolesEtherCAT Slave; CANopen with PDO and SDO Client/Server services
Interfaces and ports2× EtherCAT RJ45 (IN/OUT); CANopen; Ethernet RJ45 for configuration
CANopen data rateup to 1 Mbit/s
CANopen communicationPDO (RPDO/TPDO); SDO Client/Server
Power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the version shown (D × W × H)120 × 23 × 107 mm
Device weightapproximately 200 g
Configuration softwareSW67E08

For an older device, check the hardware version and connections against its label.