Converter EtherCAT Slave / CANopen - HD67E08-A1
Converter EtherCAT Slave / CANopen - HD67E08-A1
The ADFweb HD67E08-A1 connects a CANopen network to an EtherCAT control system. It exchanges process data as an EtherCAT Slave and uses configured PDO and SDO objects on the CANopen side. More
Code: HD67E08-A1
The ADFweb HD67E08-A1 connects a CANopen network to an EtherCAT control system. It exchanges process data as an EtherCAT Slave and uses configured PDO and SDO objects on the CANopen side. More
Code: HD67E08-A1
ADFweb HD67E08-A1
EtherCAT Slave / CANopen
The ADFweb HD67E08-A1 connects a CANopen network to an EtherCAT control system. It exchanges process data as an EtherCAT Slave and uses configured PDO and SDO objects on the CANopen side.
We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.
Converter applications
Use it to exchange values between an EtherCAT Master application and CANopen devices. Configure PDO reception/transmission and SDO Client/Server object dictionary access for the specific installation.
Technical specifications HD67E08-A1
| Order code | HD67E08-A1 |
|---|---|
| Protocol connection | EtherCAT Slave / CANopen |
| Converter roles | EtherCAT Slave; CANopen with PDO and SDO Client/Server services |
| Interfaces and ports | 2× EtherCAT RJ45 (IN/OUT); CANopen; Ethernet RJ45 for configuration |
| CANopen data rate | up to 1 Mbit/s |
| CANopen communication | PDO (RPDO/TPDO); SDO Client/Server |
| Power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 120 × 23 × 107 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67E08 |
For an older device, check the hardware version and connections against its label.
Communication and configuration
In SW67E08, configure EtherCAT, the CANopen node identifier, data rate and PDO/SDO mapping. The software exports an ESI file for the EtherCAT Master and an EDS file for the CANopen Master.
The gateway requires an EtherCAT Master. Match CANopen node identifiers, objects, data types and network state; a matching CAN connector alone is insufficient. Distinguish configuration Ethernet from EtherCAT.
Supply and accessories
Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.
Documentation and software
Diagrams and hardware version

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.
Frequently asked questions
Is knowing the two protocols enough?
The device roles, physical interfaces and data to be transferred must also be checked. The gateway requires an EtherCAT Master. Match CANopen node identifiers, objects, data types and network state; a matching CAN connector alone is insufficient. Distinguish configuration Ethernet from EtherCAT.
How is this converter configured?
In SW67E08, configure EtherCAT, the CANopen node identifier, data rate and PDO/SDO mapping. The software exports an ESI file for the EtherCAT Master and an EDS file for the CANopen Master.
What information should I send to check the selection?
Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.
FOXON support with selection and ordering
Selection based on your devices
We will review the specific connection, communication roles and required data.
Availability check
Before you place an order, we will confirm current availability and the possible delivery date.
Documentation for the exact order code
We select the documentation and configuration tool using the complete order code.
Accessories for your installation
We will include the requested accessories in the quotation to suit the connection arrangement.
Choosing the correct version
Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.
The gateway requires an EtherCAT Master. Match CANopen node identifiers, objects, data types and network state; a matching CAN connector alone is insufficient. Distinguish configuration Ethernet from EtherCAT.
Converter enquiry HD67E08-A1
Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.
Request the converterTechnical specifications HD67E08-A1
| Order code | HD67E08-A1 |
|---|---|
| Protocol connection | EtherCAT Slave / CANopen |
| Converter roles | EtherCAT Slave; CANopen with PDO and SDO Client/Server services |
| Interfaces and ports | 2× EtherCAT RJ45 (IN/OUT); CANopen; Ethernet RJ45 for configuration |
| CANopen data rate | up to 1 Mbit/s |
| CANopen communication | PDO (RPDO/TPDO); SDO Client/Server |
| Power supply | 8-24 V AC / 12-35 V DC |
| Consumption at 24 V DC | 3.5 W |
| Operating temperature | -40 °C to +85 °C |
| Mounting | 35 mm DIN rail |
| Dimensions of the version shown (D × W × H) | 120 × 23 × 107 mm |
| Device weight | approximately 200 g |
| Configuration software | SW67E08 |
For an older device, check the hardware version and connections against its label.