Converter BACnet MS/TP Slave / Modbus TCP Slave - HD67674-MSTP-A1

Converter BACnet MS/TP Slave / Modbus TCP Slave - HD67674-MSTP-A1

New

ADFweb

The ADFweb HD67674-MSTP-A1 is an industrial BACnet MS/TP Slave / Modbus TCP Slave converter. It connects both communication sides through a configured data map. More

Code: HD67674-MSTP-A1

299 EUR excl. VAT (361,79 EUR Incl. VAT)
Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
ADFweb

The ADFweb HD67674-MSTP-A1 is an industrial BACnet MS/TP Slave / Modbus TCP Slave converter. It connects both communication sides through a configured data map. More

Code: HD67674-MSTP-A1

ADFweb HD67674-MSTP-A1

BACnet MS/TP Slave / Modbus TCP Slave

The ADFweb HD67674-MSTP-A1 is an industrial BACnet MS/TP Slave / Modbus TCP Slave converter. It connects both communication sides through a configured data map.

We will check your selection and prepare a quotation
Send us the device models, required connection and quantity.

Request the converter
BACnet MS/TP Slave / Modbus TCP SlaveProtocol connection
RS485; Ethernet RJ45Interfaces
SW67674Configuration tool

Converter applications

Connect BACnet MS/TP supervision to a Modbus TCP Master control system. The converter is a Slave on both sides and shares configured data between BACnet objects and Modbus registers.

Technical specifications HD67674-MSTP-A1

Order codeHD67674-MSTP-A1
Protocol connectionBACnet MS/TP Slave / Modbus TCP Slave
Converter rolesBACnet MS/TP Slave; Modbus TCP Slave
InterfacesRS485; Ethernet RJ45
BACnet objectsup to 2000 objects in total
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the supplied versionTo be confirmed for the hardware version before ordering
Device weightapproximately 200 g
Configuration softwareSW67674

For an older device, check the hardware version and connections against its label.

Communication and configuration

Prepare the configuration in SW67674. Configure BACnet MS/TP addressing, Modbus TCP Slave network settings and object-to-register mappings. The supervisory Modbus Master must use the same data map.

This version uses BACnet MS/TP over RS485. Prepare device addresses, bus parameters and the object list with data types and required read/write operations. Master and Slave roles must match the counterparts; the BACnet/IP version has a different interface.

Supply and accessories

Please provide the complete order code. If you need a power supply, connection cables or help with configuration, include them in your enquiry. We will confirm the scope of supply and required accessories for your installation in the quotation.

Documentation and software

Diagrams and hardware version

Dimensional drawing of the version shown - HD67674-MSTP-A1
Dimensional drawing of the version shown - HD67674-MSTP-A1

The images help identify the hardware version. When replacing an older unit, compare its label, connectors and dimensions; we will confirm the version to be supplied in the quotation.

Frequently asked questions

Is knowing the two protocols enough?

The device roles, physical interfaces and data to be transferred must also be checked. This version uses BACnet MS/TP over RS485. Prepare device addresses, bus parameters and the object list with data types and required read/write operations. Master and Slave roles must match the counterparts; the BACnet/IP version has a different interface.

How is this converter configured?

Prepare the configuration in SW67674. Configure BACnet MS/TP addressing, Modbus TCP Slave network settings and object-to-register mappings. The supervisory Modbus Master must use the same data map.

What information should I send to check the selection?

Send the exact device models at both ends, the protocols and communication roles, the number of devices and the required values. For a PLC, include the firmware and method of accessing its data.

FOXON support with selection and ordering

Selection based on your devices

We will review the specific connection, communication roles and required data.

Availability check

Before you place an order, we will confirm current availability and the possible delivery date.

Documentation for the exact order code

We select the documentation and configuration tool using the complete order code.

Accessories for your installation

We will include the requested accessories in the quotation to suit the connection arrangement.

Choosing the correct version

Two devices with the same protocols can have different functions. Check the gateway role on each side, the connectors and the complete order code.

This version uses BACnet MS/TP over RS485. Prepare device addresses, bus parameters and the object list with data types and required read/write operations. Master and Slave roles must match the counterparts; the BACnet/IP version has a different interface.

Converter enquiry HD67674-MSTP-A1

Provide the order code, quantity and the devices you need to connect. We will check the suitable version and prepare a quotation.

Request the converter

Technical specifications HD67674-MSTP-A1

Order codeHD67674-MSTP-A1
Protocol connectionBACnet MS/TP Slave / Modbus TCP Slave
Converter rolesBACnet MS/TP Slave; Modbus TCP Slave
InterfacesRS485; Ethernet RJ45
BACnet objectsup to 2000 objects in total
Converter power supply8-24 V AC / 12-35 V DC
Consumption at 24 V DC3.5 W
Operating temperature-40 °C to +85 °C
Mounting35 mm DIN rail
Dimensions of the supplied versionTo be confirmed for the hardware version before ordering
Device weightapproximately 200 g
Configuration softwareSW67674

For an older device, check the hardware version and connections against its label.