COM Server 3x RS232 / RS422 / RS485, PoE

COM Server 3x RS232 / RS422 / RS485, PoE


W&T

Industrial COM Server Adapter for connecting up to 3 devices with RS232/422/485 serial port to a PC via Ethernet. The COM Port Redirector program is installed on the computer to create up to 3 virtual COM ports. It supports Box-to-Box mode and data transfer from devices before OPC DA protocol. Power supply via PoE or 12-48 VDC / 9-24VAC. More

Code: 58662

618 EUR excl. VAT (747,78 EUR Incl. VAT)
Quantity discount
Units
Discount
Price without VAT

0 - 4
0%
618,00

5 - 9
2%
605,64

10 - 19
5%
587,10

20 and more
9%
562,38

In stock
pcs
(1 pcs In stock)

Rezervace termínu

Get a quote
W&T

Industrial COM Server Adapter for connecting up to 3 devices with RS232/422/485 serial port to a PC via Ethernet. The COM Port Redirector program is installed on the computer to create up to 3 virtual COM ports. It supports Box-to-Box mode and data transfer from devices before OPC DA protocol. Power supply via PoE or 12-48 VDC / 9-24VAC. More

Code: 58662

W&T 58662

Three galvanically isolated serial ports via Ethernet

The W&T Com-Server PoE 3x Isolated 58662 connects three serial devices to a 10/100BaseT Ethernet network. Each port can be configured for RS232, RS422 or RS485. The serial ports are galvanically isolated from one another and from the power supply.

Do you need to select or order the W&T 58662?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.

Enquire about purchasing or repairing a part
3 serial portsOptional: RS232 / RS422 / RS485
1 kV SectionSerial ports in relation to each other and to the power supply
PoE or external power supplyEthernet 10/100BaseT

Usage

It is used for the network connection of multiple serial devices, meters and other equipment. It supports virtual COM ports in Windows, communication via TCP/UDP and Box-to-Box connections between Com-Servers.

Technical specifications for W&T 58662

Serial port3x RS232/422/485 interfaces, optional
DB9, male
50 to 230,400 Bd
7 or 8 data bits
1 or 2 stop bits
Parity: none, even or odd
Flow control: none, RTS/CTS or XON/XOFF
Serial interface modesRS232
RS422, four-wire, bus master
RS485, four-wire, bus master
RS485, four-wire, automatic control
RS485, two-wire, automatic control
Network interface10/100BaseT, auto-detection / Auto-MDIX
RJ45
IPv6 on request
Galvanic isolationNetwork interface section: min. 1500 V
Serial ports: 1 kV relative to each other and to the power supply
Supply voltagePower-over-Ethernet (PoE) or
12–48 V DC (±10 per cent) or 9–24 V AC, root mean square (±10 per cent)
Power connectionRemovable screw terminal block, pitch 5.08 mm
Marked ‘L+’ and ‘M’
Current consumptionPoE Class 1 (0.44–3.84 W)
typ. 110 mA at 24 V DC with an external power supply
Signalling1× power LED
3× status LEDs
3× error LEDs
2× network status LEDs
Housing and mountingCompact plastic housing for DIN rail mounting
105 × 45 × 75 mm (d × w × h)
Degree of protectionIP20
Weightapprox. 180 g
Ambient temperatureStorage: -40 to +70 °C
Operating temperature 0 to +60 °C (70 °C on request)
Permissible relative humidity5 to 95 per cent RH, non-condensing
Contents of the delivery1x Com-Server, 3x isolated
1× quick start guide

Serial modes and network communication

  • Each serial port has a DB9 connector and a baud rate of 50 to 230,400 Bd. The interface type and transmission parameters are selected according to the connected device.
  • Supported services include a virtual COM port, TCP/UDP, Box-to-Box, a Modbus TCP gateway for Modbus RTU slaves, FTP, Telnet, SLIP and Wake-on-LAN.
  • The current version also supports a virtual COM port and a TCP server with optional TLS-PSK and encrypted Box-to-Box. Please check the firmware to verify the availability of these features on your existing unit.
  • The network interface has an isolation rating of at least 1500 V. The 1 kV isolation of the serial ports applies to both their mutual isolation and their isolation from the power supply.

Commissioning and accessories

Set the IP address using WuTility or DHCP. For each port, select the electrical interface, wiring configuration, baud rate and flow control. For virtual COM ports, install the appropriate W&T COM Port Redirector.

Contents of the delivery

  • 1x Com-Server, 3x isolated
  • 1× quick start guide

Frequently Asked Questions

Are there really three independent serial ports here?

Yes. Unlike the model with a single switchable port, the 58662 model provides three serial ports. Each can be configured as RS232, RS422 or RS485.

What does the term ‘Isolated’ mean?

The serial ports are galvanically isolated from one another and from the power supply, with a specified insulation rating of 1 kV. The network interface has a separately specified isolation rating of at least 1500 V.

Is a matching DB9 connector sufficient for connecting the device?

No. The electrical interface, pin configuration, protocol and timing requirements of the specific application must also be met.

Why order from FOXON?

Before placing an order, we will check the current availability of the part and confirm the estimated delivery date. We will assist you in selecting the equipment and necessary accessories based on the wiring configuration and required communication. We will confirm the warranty terms and the scope of any diagnostics or repairs for the specific quotation.

More than 3,500customers
We supply tomore than 100 countries worldwide
Express delivery?We will look into this; please contact us immediately.

Documentation and technical consultancy

Technical data and documentation W&T 58662

Manuals, firmware and tools for this model can also be found in the Downloads tab. For service enquiries, please use sale and repair of FOXON industrial parts.

Do you need to select or order the W&T 58662?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.

Enquire about purchasing or repairing a part

Technical specifications for the W&T 58662

Serial port3x RS232/422/485 interfaces, optional
DB9, male
50 to 230,400 Bd
7 or 8 data bits
1 or 2 stop bits
Parity: none, even or odd
Flow control: none, RTS/CTS or XON/XOFF
Serial interface modesRS232
RS422, four-wire, bus master
RS485, four-wire, bus master
RS485, four-wire, automatic control
RS485, two-wire, automatic control
Network interface10/100BaseT, auto-detection / Auto-MDIX
RJ45
IPv6 on request
Galvanic isolationNetwork interface section: min. 1500 V
Serial ports: 1 kV relative to each other and to the power supply
Supply voltagePower-over-Ethernet (PoE) or
12–48 V DC (±10 per cent) or 9–24 V AC, root mean square (±10 per cent)
Power connectionRemovable screw terminal block, pitch 5.08 mm
Marked ‘L+’ and ‘M’
Current consumptionPoE Class 1 (0.44–3.84 W)
typ. 110 mA at 24 V DC with an external power supply
Signalling1× power LED
3× status LEDs
3× error LEDs
2× network status LEDs
Housing and mountingCompact plastic housing for DIN rail mounting
105 × 45 × 75 mm (d × w × h)
Degree of protectionIP20
Weightapprox. 180 g
Ambient temperatureStorage: -40 to +70 °C
Operating temperature 0 to +60 °C (70 °C on request)
Permissible relative humidity5 to 95 per cent RH, non-condensing
Contents of the delivery1x Com-Server, 3x isolated
1× quick start guide