- Switches and Wi-Fi
- Industrial Wi-Fi
- WiFi Access Point
- ACKSYS AirWave – Industrial WiFi 6 Access Point and Client
ACKSYS AirWave – Industrial WiFi 6 Access Point and Client
ACKSYS AirWave is an industrial Wi-Fi 6 access point, client and router with two simultaneously operating 2.4 and 5 GHz radios. It offers 1× 2.5 Gigabit Ethernet RJ45, 9-48 VDC or PoE power supply, IP30 protection and an operating temperature range of 0 to +65 °C. It is designed for machines, AGVs and AMRs. More
Code: AirWave
ACKSYS AirWave is an industrial Wi-Fi 6 access point, client and router with two simultaneously operating 2.4 and 5 GHz radios. It offers 1× 2.5 Gigabit Ethernet RJ45, 9-48 VDC or PoE power supply, IP30 protection and an operating temperature range of 0 to +65 °C. It is designed for machines, AGVs and AMRs. More
Code: AirWave
ACKSYS AirWave - Industrial Wi-Fi 6 for machines, AGVs and AMRs
ACKSYS AirWave is a compact industrial wireless device featuring Wi-Fi 6 (IEEE 802.11ax), designed primarily for applications where stable Wi-Fi communication is required even when the device is in motion.
Typical uses include AGV and AMR robots, logistics vehicles, mobile machinery, PLCs, production lines and other industrial automation equipmentAirWave can operate as Wi-Fi client, access point, router, repeater or optional mesh device.

Selecting devices and accessories
Please send us a description of the application, the number of devices and your communication requirements. We will recommend suitable models and accessories.
Fast Roaming for AGVs and mobile machinery
When an AGV, AMR or other machine moves through the production hall, the Wi-Fi client must switch between individual access points. AirWave utilises Fast Roaming, which helps to reduce the transition time between APs and minimise communication outages.
Two WiFi radios operating simultaneously
AirWave contains two Wi-Fi 6 radios for the bands 2.4 GHz and 5 GHz. Both can operate simultaneously, enabling a more flexible design of industrial Wi-Fi infrastructure and supporting more demanding mobile applications.
Wi-Fi 6 for industrial applications
Wi-Fi 6 technology utilises OFDMA and MU-MIMO for more efficient wireless communication when multiple devices are in use. In the 5 GHz band, AirWave achieves speeds of up to 1201 Mbit/s.
Universal AP, client and router
A single type of device can be used to connect a machine to an existing Wi-Fi network, create a local access point, provide a wireless connection for Ethernet devices or route traffic between individual network segments.
Usage
AirWave is particularly suitable where industrial equipment is mobile, requires a reliable Wi-Fi connection, or where Ethernet devices need to be connected wirelessly to the corporate network.
Wi-Fi for PROFINET, EtherNet/IP and Modbus/TCP
AirWave can be used not only for standard Ethernet communication, but also for the transmission of data used in industrial automation. It is therefore suitable, for example, for wireless connections PLCs, HMIs, robots, remote I/O or other Ethernet devices.
When the Wi-Fi infrastructure is properly designed, AirWave can be used in applications with industrial Ethernet protocols where a fixed or mobile machine needs to be connected wirelessly.
High-performance Wi-Fi and Ethernet interfaces
AirWave uses technology MIMO 2T2R and supports Wi-Fi 6 in the 2.4 GHz and 5 GHz bands. For wired connections, it is equipped with 2.5 Gigabit Ethernet with an RJ45 port, which provides sufficient bandwidth even for high-speed Wi-Fi communication.
Industrial design and flexible power supply
AirWave is housed in a compact metal enclosure and is designed for mounting directly onto industrial equipment or in a control cabinet. It can be installed on DIN rail or wall-mounted.
Power supply is possible across a wide range 9-48 VDC or via PoE IEEE 802.3af. Two RP-SMA antenna connectors allow you to select the appropriate type of external antenna for your specific application.
- metal industrial design
- DIN rail or wall mounting
- Power supply: 9-48 VDC
- PoE IEEE 802.3af
- 2 × RP-SMA for external antennas
- Operating temperature: 0 to +65 °C
- IP 30 protection
Industrial Wi-Fi security
AirWave supports modern security technologies to protect both wireless and wired communications. Features available include, for example, WPA3, 802.1X/RADIUS, a firewall, VPN, Secure Boot and secure access to device administration.
- WPA3
- 802.1X / RADIUS
- firewall and protection against DoS attacks
- HTTPS
- OpenVPN and IPsec
- SNMPv3
- Secure Boot
WaveOS & WaveManager
Configuration, diagnostics and centralised management of ACKSYS industrial Wi-Fi devices.
AirWave uses an operating system ACKSYS WaveOS. Configuration and diagnostics can be carried out via the web interface, HTTPS, SNMP, MQTT or CLI.
For a larger number of devices, you can use ACKSYS WaveManager for centralised configuration, monitoring and management of Wi-Fi infrastructure. This is particularly useful in manufacturing and logistics halls with a large number of AGVs, AMRs or other wirelessly connected devices.
Power supply and memory card
Use a 9-48 VDC power supply or PoE, but never both at the same time. A short-term drop to 7 V is not permitted as a continuous power supply. AirWave has a microSD slot for configuration and logs; the availability of individual functions depends on the firmware version. Advanced Mesh is an optional feature.
Contents of the package
AirWave is supplied with Wi-Fi antennas. The PWS12-UNI-PH3 power adaptor, WL-FIX-RD2 DIN rail mount, WL-PLT-2 mounting plate and magnetic antenna bases must be ordered separately. WaveManager 4.6.0.1 or later is required for centralised management.
WaveOS and centralised management
Configuration and diagnostics are carried out via the interface supported by the specific model. WaveManager is available as an on-premises or cloud solution; the licence, number of managed devices and required features are selected according to the installation. Before updating the firmware, save the configuration and verify compatibility. The EN 18031 security updates remove weak encryption and authentication methods; it is therefore necessary to check the network settings in advance.
Design guidelines
For a fixed link, provide the distance, obstacles, required throughput and antenna locations. For AGVs and mobile machinery, include the route, existing access points and required response time. For a mobile router, please specify the network operator, the bands used, the power supply and any GNSS requirements.
Selection and technical consultation at FOXON
We can help you select the model, power supply, antennas and cabling to suit your specific equipment and environment. When designing a Wi-Fi connection, we need to know the distance, any obstacles, the movement of devices and the application requirements. We will confirm current availability and the delivery date in our quotation.
Frequently Asked Questions
Actual data transfer rate
The radio speed specified for Wi-Fi does not represent the actual application throughput. The result is affected by interference, channel width, antennas, distance, obstacles and traffic from other devices. Please provide the required throughput and a description of the environment for a proposal.
Transmission of industrial protocols
WiFi devices transmit Ethernet communication. They do not replace a PLC or a protocol converter. For PROFINET, EtherNet/IP and other time-sensitive applications, it is necessary to verify the topology, cycle time and behaviour during roaming.
Antennas and cables
Connector types and the number of antennas vary by model. Before ordering, please check the full router model number, Ethernet ports, power supply and installation requirements. The contents of the package are listed separately.
Documentation and related materials
Technical documents are in the language specified. A Czech or other translated file name does not imply that the PDF itself has been translated.
- AirWave - EN catalogue sheet
- AirWave - Hardware Manual EN
- WaveOS - User Manual EN, Rev. A.19
- WaveManager 4 - User Manual EN, version 4.6.0.1
- WaveManager On Premise - Feature Overview EN, Rev. A1
- WaveManager Cloud - Feature Overview EN, rev. A1
Further documentation and current manufacturer’s materials from ACKSYS
Quotation for a specific installation
Please send us a description of the application, the number of devices and your communication requirements. We will recommend suitable models and accessories.
Technical specifications
| Ethernet | 1 × 2.5 Gigabit Ethernet Base TX with auto-negotiation, auto MDI/MDIX switching (10/100/1000/2500), RJ45 Ethernet interface |
|---|---|
| Wi-Fi | 2 concurrent WiFi6 (IEEE 802.11ax) radio modules at 2.4 GHz and 5 GHz, MIMO 2T2R, ANI (Adaptive Noise Immunity) |
| Antenna connectors | 2 x RP-SMA |
| Security | EN18031 with firewall, CRA, DoS, HTTPS, MAC address filtering, WPA/WPA2/WPA3-Personal & Enterprise (IEEE 802.1X/RADIUS), L2 tunnels (GRE), VPN (OpenVPN, IPsec), SNMP V3, unauthorised access point detector, Secure BOOT |
| Network functions | IPv4/IPv6 support, frame filtering, bridging, repeater, STP/RSTP, VLAN, DHCP (server and client), DNS relay |
| Routing | Multicast (PIM), IP redundancy (VRRP), static routes, 1:1 NAT, NAT router, router |
| Power consumption | IDLE mode: 4 W / Maximum average power consumption: 10 W / Recommended power supply: 15 W |
| Dimensions and weight | Compact housing: width: 105 x length: 79 x height: 30 mm without DIN rail or mounting plate, 236 g |
| Manufacturer’s warranty | 5 years |
| Environment | IP 30; operating temperature 0 to +65 °C; storage temperature -40 to +85 °C; relative humidity 0 to 99 per cent, non-condensing. |
| Operating modes | Access point, client, router, repeater; optional advanced mesh network |
| Power supply | 9 to 48 VDC via a 3-pin Phoenix terminal block or IEEE 802.3af PoE. Do not use DC power and PoE simultaneously. |
| Administration | HTTPS, SNMP, MQTT, CLI; WaveManager4.6.0.1 or later. MicroSD card slot for configuration and logs; supported features depend on the firmware. |
Highlighted items are mandatory.