SIRIUS 3RN2 thermistor motor protection relay, standard evaluation unit with a width of 22.5 mm. Power supply 24 to 240 V AC/DC, 2 changeover contacts, spring-loaded terminals and manual, automatic and remote reset. 2 LEDs (ready/tripped). ATEX approval. Electrical isolation. Test/reset button. Sensor circuit open-circuit monitoring. Sensor circuit short-circuit monitoring. Power failure status memory. More
Code: 3RN2012-2BW30
SIRIUS 3RN2 thermistor motor protection relay, standard evaluation unit with a width of 22.5 mm. Power supply 24 to 240 V AC/DC, 2 changeover contacts, spring-loaded terminals and manual, automatic and remote reset. 2 LEDs (ready/tripped). ATEX approval. Electrical isolation. Test/reset button. Sensor circuit open-circuit monitoring. Sensor circuit short-circuit monitoring. Power failure status memory. More
Code: 3RN2012-2BW30
3RN2012-2BW30 - thermistor motor protection relay
SIRIUS 3RN2 thermistor motor protection relay, standard evaluation unit with a width of 22.5 mm. Power supply 24 to 240 V AC/DC, 2 changeover contacts, spring-loaded terminals and manual, automatic and remote reset. 2 LEDs (ready/tripped). ATEX approval. Electrical isolation. Test/reset button. Sensor circuit open-circuit monitoring. Sensor circuit short-circuit monitoring. Power failure status memory.
Would you like to buy or repair this part?
We will check the availability of the spare part as well as the options for diagnosing and repairing your faulty part.
Applications
The relay evaluates the motor’s thermal protection circuit and transmits its status to the downstream control system. When selecting a relay, compare the sensor type, power supply, contacts and the required reset function.
Technical specifications according to Siemens
| Manufacturer | SIEMENS |
|---|---|
| Order number | 3RN2012-2BW30 |
| Series / system | SIRIUS 3RN2 |
| Version | Standard evaluation unit with ATEX certification, detection of open circuits and short circuits in the sensor circuit, non-volatile |
| Functions | thermistor motor protection |
| Type of control voltage | AC/DC |
| Rated control voltage DC | 24 ... 240 V |
| Number of auxiliary normally open contacts | 0 |
| Number of auxiliary switching contacts | 0 |
| Number of switching auxiliary contacts | 2 |
| Rated frequency | 50 ... 60 Hz |
| Electrical connection | spring-loaded terminal (plug-in) |
| Mounting position | any |
| Mounting method | Mounting using screws and snap-fit on a 35 mm DIN rail |
| Dimensions W × H × D | 22.5 mm × 100 mm × 90 mm |
| Net weight | 0.145 kg |
Protective circuit and reset
The reset procedure and diagnostic functions vary depending on the specific variant. The automatic reset must correspond to the required behaviour of the motor output once the fault has cleared. Assess any ATEX application in accordance with the approval conditions for the entire circuit.
Scope of supply
The evaluation relay itself. Sensors in the motor, the contactor and other parts of the motor output are not automatically included in the scope of supply.
We will confirm the exact condition of the part and the contents of the specific delivery in the quotation.
Frequently Asked Questions
How can I check that a spare part is the correct model?
Please send the full order number and a photograph of the label on the original part. We will check that the design matches; similar labelling does not in itself confirm the same wiring or functions.
Does the relay measure the motor current directly?
This concerns the evaluation of a thermal protection circuit. It cannot automatically be confused with a current monitoring relay or a motor circuit breaker.
Can you carry out diagnostics or repairs?
Please send us a description of the fault and the details from the label. We will assess the options for diagnosis and repair, as well as the availability of spare parts. For passive and mechanical components, we will first assess whether repair is worthwhile based on their condition.
Why buy from FOXON
Spare part availability
We will check the current availability of the part and confirm the estimated delivery date before you place your order.
New original and refurbished parts
Depending on current availability, we will check for a new original part or a reconditioned alternative.
Parts with a warranty
We will confirm the condition of the specific part and the warranty terms in our quotation.
Diagnostics and repair
As well as purchasing a spare part, we will also check the options for diagnosing and repairing your faulty part.
Available part conditions
Depending on current availability, we offer new original parts, new parts from previous stock, as well as reconditioned or used, tested variants. We will confirm the availability of a specific model, the price, the scope of delivery and the warranty before you place your order. The options listed do not imply that all variants are currently in stock.
Sales, repairs and purchase of surplus automation parts
We supply spare parts for industrial automation and assess options for diagnosing and repairing faulty equipment. You can also offer us any unwanted parts for purchase.
Purchase or repair of part 3RN2012-2BW30
Please provide the full order number, the required quantity and, in the case of a repair, a description of the fault. We will check the availability of the spare part as well as the options for diagnosis and repair.
Request purchase or repair of a part