- Machine data collection
- OPC UA / MQTT Sensors
- High precision Ethernet thermometer and hygrometer, Modbus TCP, REST, MQTT, OPC UA
High precision Ethernet thermometer and hygrometer, Modbus TCP, REST, MQTT, OPC UA
Thermometer with hygrometer, stores data in internal memory or provides it over Ethernet network to parent applications via OPC UA/DA, MQTT, REST, Modbus TCP, etc. JavaScript support for browser data display, alarm system, W&T Cloud support. DIN rail mounting. Possibility to certify measurements for 1 year. More
Code: 57729
Thermometer with hygrometer, stores data in internal memory or provides it over Ethernet network to parent applications via OPC UA/DA, MQTT, REST, Modbus TCP, etc. JavaScript support for browser data display, alarm system, W&T Cloud support. DIN rail mounting. Possibility to certify measurements for 1 year. More
Code: 57729
Precise measurement of temperature and humidity on the network
The W&T 57729 is a networked measurement system with a separate probe for temperature and relative humidity. It offers web-based visualisation, internal data logging and connectivity via OPC UA, MQTT, REST and Modbus TCP.
Do you need to select or order the W&T 57729?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.
Usage
The precision combination probe is designed, for example, for use in laboratories, for monitoring storage conditions and for measurements in high-humidity environments. The typical error depends on the temperature and conditions specified in the table; it is not a single value applicable across the entire range.
Technical specifications for W&T 57729
| Combined sensor | Temperature and relative humidity measurement M8 connector Cable length: 2 m, can be extended to a maximum of 20 m |
|---|---|
| Network interface | 10/100BaseT, auto-detection / Auto-MDIX RJ45 IPv6 on request |
| Galvanic isolation | Network interface section: min. 1500 V |
| Supply voltage | Power-over-Ethernet (PoE) or 12–48 V DC (±10 %) |
| Power connection | Removable screw terminal block, pitch 5.08 mm Marked ‘L+’ and ‘M’ |
| Current consumption | PoE Class 1 (0.44–3.84 W) typ. 110 mA at 12 V, 55 mA at 24 V DC |
| Signalling | 1× power LED 2× network status LEDs 2 LEDs: Status and fault |
| Measuring range | -20 °C to 80 °C, 0 to 100 per cent relative humidity |
| Resolution | 1/10 °C, 1/10 % rH |
| Quantities displayed | Temperature: °C, °F, K; relative humidity: % RH; absolute humidity: g/m³; dew point: °C; mixing ratio: g/kg; enthalpy: kJ/kg |
| Measurement error | Temperature: Typical error: ±0.1 K at 0 to +70 °C Typical error: ±0.2 K at -20 to +80 °C Relative humidity: typ. ±0.5 % relative humidity at temperatures between 15 and 30 °C typ. ±0.8 % relative humidity at temperatures between 0 and 50 °C typ. ±2.5% relative humidity at temperatures ranging from -20 to 80 °C |
| Measurement period | 4s |
| Save interval | 15 s, 30 s, 1 min, 5 min, 15 min, 60 min |
| History capacity (4 MB memory) | min. 12 weeks, max. 20 years |
| Housing and mounting | Compact plastic housing for DIN rail mounting |
| Dimensions | 105 × 22 × 75 mm (length × width × height) |
| Degree of protection | IP20 |
| Weight | approx. 200 g |
| Ambient temperature | Storage: -10 to 60 °C Module operating temperature with spacing between devices: 0 to +60 °C Module operation without spacing between devices: 0 to +50 °C Sensor operating temperature: -20 to 80 °C |
| Permissible relative humidity | 0 to 100 per cent relative humidity |
| Contents of the delivery | 1x web-based thermo-hygrometer 1x sensor, 2 m (temperature, humidity) 1× quick start guide |
Measured quantities and conditions of use
- The precision combination probe is designed, for example, for use in laboratories, for monitoring storage conditions and for measurements in high-humidity environments. The typical error depends on the temperature and conditions specified in the table; it is not a single value applicable across the entire range.
- The scope of supply includes a combined probe with a 2 m cable. W&T permits the probe connection to be extended to a maximum of 20 m for this model.
- Values are updated every 4 seconds. The history is stored at separate intervals: 15 or 30 seconds, or 1, 5, 15 or 60 minutes.
- Up to 12 configurable alerts enable notifications via email or SNMP. The network module and probe have their own operating conditions; the probe’s measurement range is not the same as the module’s operating temperature.
- When taking measurements outdoors, the probe must be fitted with a suitable cover to protect it from sunlight and precipitation. An IP20 rating for a network module does not imply resistance to rain.
Commissioning and accessories
Position the probe so that it measures the required area and is not affected by heat from surrounding equipment. Set the IP address, the displayed parameters, the logging interval and the alarm limits. If extending the cable, use suitable cabling and do not exceed a length of 20 m.
Contents of the delivery
- 1x web-based thermo-hygrometer
- 1x sensor, 2 m (temperature, humidity)
- 1× quick start guide
Frequently Asked Questions
Can I extend the probe cable?
Yes. This model comes with a 2-metre cable, which can be extended to a maximum of 20 metres. Use cabling that complies with the manufacturer’s wiring specifications.
Does the temperature measurement range also apply to the network module?
No. The measurement range applies to the probe. The module itself has its own specified operating temperature and installation conditions.
What does the stated typical accuracy mean?
Applies under the conditions specified for the particular quantity and range in the table. When assessing these, it is necessary to distinguish between temperature, relative humidity and, where applicable, pressure, as well as long-term stability.
Why buy from FOXON
W&T distributor
We are a distributor of W&T products. We supply new original products with a warranty.
Stock availability and delivery
We check current availability from our own and partner warehouses. Before you order, we confirm the price and possible delivery date for the specific model.
Product selection and technical advice
We help you choose the model, power supply and accessories to suit your connections and communication requirements.
Solution design and configuration
We discuss the connections and application requirements. Where needed, we propose a suitable setup and agree on the scope of assistance with configuration and commissioning.
Documentation and technical consultancy
Technical data and documentation W&T 57729
Manuals, firmware and tools for this model are also available in the Downloads tab. We can help with product selection and configuration according to your connections and communication requirements.
Do you need to select or order the W&T 57729?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.
Diagrams and illustrations

Further related links
Technical specifications for W&T 57729
| Combined sensor | Temperature and relative humidity measurement M8 connector Cable length: 2 m, can be extended to a maximum of 20 m |
|---|---|
| Network interface | 10/100BaseT, auto-detection / Auto-MDIX RJ45 IPv6 on request |
| Galvanic isolation | Network interface section: min. 1500 V |
| Supply voltage | Power-over-Ethernet (PoE) or 12–48 V DC (±10 %) |
| Power connection | Removable screw terminal block, pitch 5.08 mm Marked ‘L+’ and ‘M’ |
| Current consumption | PoE Class 1 (0.44–3.84 W) typ. 110 mA at 12 V, 55 mA at 24 V DC |
| Signalling | 1× power LED 2× network status LEDs 2 LEDs: Status and fault |
| Measuring range | -20 °C to 80 °C, 0 to 100 per cent relative humidity |
| Resolution | 1/10 °C, 1/10 % rH |
| Quantities displayed | Temperature: °C, °F, K; relative humidity: % RH; absolute humidity: g/m³; dew point: °C; mixing ratio: g/kg; enthalpy: kJ/kg |
| Measurement error | Temperature: Typical error: ±0.1 K at 0 to +70 °C Typical error: ±0.2 K at -20 to +80 °C Relative humidity: typ. ±0.5 % relative humidity at temperatures between 15 and 30 °C typ. ±0.8 % relative humidity at temperatures between 0 and 50 °C typ. ±2.5% relative humidity at temperatures ranging from -20 to 80 °C |
| Measurement period | 4s |
| Save interval | 15 s, 30 s, 1 min, 5 min, 15 min, 60 min |
| History capacity (4 MB memory) | min. 12 weeks, max. 20 years |
| Housing and mounting | Compact plastic housing for DIN rail mounting |
| Dimensions | 105 × 22 × 75 mm (length × width × height) |
| Degree of protection | IP20 |
| Weight | approx. 200 g |
| Ambient temperature | Storage: -10 to 60 °C Module operating temperature with spacing between devices: 0 to +60 °C Module operation without spacing between devices: 0 to +50 °C Sensor operating temperature: -20 to 80 °C |
| Permissible relative humidity | 0 to 100 per cent relative humidity |
| Contents of the delivery | 1x web-based thermo-hygrometer 1x sensor, 2 m (temperature, humidity) 1× quick start guide |

VIDEO: Easily Collect Machine Data via OPC UA & MQTT
At the beginning of 2024 we introduced a new product from the German manufacturer of industrial modules W&T to the Czech market. Check out our short videos to see how easy it is to set up and use W&T sensors and digital and analogue inputs and outputs for data acquisition using OPC UA and MQTT communications.
Highlighted items are mandatory.


