Ethernet Thermometer 2x Pt100/Pt1000 sensors via terminal block, Modbus TCP, REST, MQTT, OPC UA

Ethernet Thermometer 2x Pt100/Pt1000 sensors via terminal block, Modbus TCP, REST, MQTT, OPC UA


Industrial module for remote monitoring and data acquisition of two temperatures, measured via 2x independent Pt100 W&T sensors -50C...180C, via measuring input with range -200C...650C each. Sensor connection via 8-pin terminal block, cable length 2m, can be extended. Temperature data is also provided via OPC UA/DA, REST, MQTT, Modbus TCP or Web Server. Built-in data logger for archiving data to FTP, Excel, ODBC, W&T cloud or custom memory with min 16 weeks and max 20 years, storage in 15,30sec or 1,5,15,60min increments. Alarm system with email notification, automatic control of outputs according to input. Data readout after 4sec, power supply 12-48VDC or PoE, DIN mounting. More

Manufacturer: W&T Code: 57707

438 EUR excl. VAT (529,98 EUR incl. VAT)
Recycling fee 0,04 EUR v cene.
Delivery 3-8 days Watch availability
pcs
(0 pcs in stock)
Buy more for 230 EUR and get free delivery!
0 EUR230 EUR

Industrial module for remote monitoring and data acquisition of two temperatures, measured via 2x independent Pt100 W&T sensors -50C...180C, via measuring input with range -200C...650C each. Sensor connection via 8-pin terminal block, cable length 2m, can be extended. Temperature data is also provided via OPC UA/DA, REST, MQTT, Modbus TCP or Web Server. Built-in data logger for archiving data to FTP, Excel, ODBC, W&T cloud or custom memory with min 16 weeks and max 20 years, storage in 15,30sec or 1,5,15,60min increments. Alarm system with email notification, automatic control of outputs according to input. Data readout after 4sec, power supply 12-48VDC or PoE, DIN mounting. More

Manufacturer: W&T Code: 57707

Sensor:

  • Two measurement inputs Pt100/Pt1000:
    • Measuring input, each: -200°C...650°C
    • Measuring range with W&T probe (1x included): -50°C...180°C

Connectivity:

  • Intuitive Web interface for simpler configuration
  • Monitor temperatures and trends from a browser
  • Alarm and reporting function:
    • E-mail for alarm or reporting functions
    • SNMP polling / alarm traps
    • Configure up to 12 alarm messages
  • Dynamic integration into other Web sites:
    • Direct access to current measurement values, e.g. JavaScript (AJAX).
  • Current Industry 4.0 protocols:
    • OPC UA, REST and MQTT support
  • Additional software interfaces for incorporating into your systems/databases:
    • SNMPv1, SNMPv2c, SNMPv3
    • Modbus-TCP
    • OPC UA, OPC DA
    • Syslog
    • Sensobase (database integration via ODBC)
    • TCP and UDP sockets, client and server
    • FTP (data logging)
  • Possible applications:
    • Monitor temperatures in the server room, network cabinet or office
    • Logging of measurements via FTP, Excel file, email attachment and internal memory
    • Green IT: Monitor efficiency of the server room climate control

Data logger:

  • Internal data logger
    • Memory capacity: min. 16 weeks, max. 20 years
    • Save frequency: 15, 30 sec, 1, 5, 15, 60 min
  • Document measurement data online in the W&T Cloud and access from anywhere in the world
  • Internal clock
    • Time synchronization via time server calibration
    • Battery-backed device clock

Standards & more

  • optional: ISO factory calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified documentation of the measured value deviations
    • Valid for 12 months
  • optional: DAkkS/DKD calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified traceability to national standards
    • Valid for 12 months
  • Supply voltage via Power-over-Ethernet (PoE)
    • Phantom power using data pairs
    • Power over unused wire pairs
    • External power supply is an alternative
  • Conforms to standards both in office and industrial environments:
    • High noise resistance per EN 61000-6-2
    • Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
  • 5 year guarantee

Connections and displays:

  • Temperature sensor:
    • 2x Pt100/Pt1000 measuring input
    • Cable length for W&T probe: 2m (can be extended as needed)
    • Enclosure rating: IP67
  • Temperature input:
    • 8-pin terminal block
    • Conductor cross-section 0.2-1.3mm²
    • Stripped length 6-8mm
  • Network:
  • Galvanic isolation:
    • Network connection min. 1500 V
  • Power supply:
    • Power-over-Ethernet (PoE) or
    • DC 12V .. 48V (+/-10%)
  • Current consumption:
    • PoE Class 1 (0.44 - 3.84W)
    • typ. 70mA @ 24V DC with external supply
  • Displays:
    • 1 LED power
    • 2 LEDs network status
    • 4 LEDs status and error

Measuring unit:

  • Sensor:
    • 2x Pt100/Pt1000 terminals 2-,3- or 4-conductor
  • Measuring range:
    • W&T sensor: -50°C...180°C
    • PT100/PT1000 measuring input: -200°C...650°C
  • Resolution:
    • 1/10°C
  • Maximum measuring error:
    •  
  • Measuring unit
    • ±0.3°C, ±0.2% Enlarge diagram
  • PT100/1000 Sensor Class A
    • ±0.15°C, ±0.2% Enlarge diagram
  • Measuring frequency:
    • 4 seconds
  • Storage frequency:
    • 15s, 30s, 1m, 5m, 15m, 60m
  • Memory depth (4MB):
    • min. 4 weeks, max. 20 years

Housing and other data:

  • Housing:
    • Plastic compact housing for top-hat rail mount
    • 105x22x75mm (LxWxH)
  • Enclosure rating:
    • IP20
  • Weight:
    • approx. 200g
  • Ambient temperature
    • Storage: -40..+70°C
    • Operating: Non-contiguous mounting: 0 .. +60°C
    • contiguous mounting: 0 .. +50°C
  • Permissible relative humidity:
    • 0..95% RH (non-condensing)
  • Scope of delivery:
    • 1x Web Thermometer 2x
    • 1x Pt100 sensor, 2m, IP67
    • 1x Quick Guide